# EA-PSB 10500-10 2U EA Elektro Automatik BiPolar Power Supply New

## Key Features at a Glance

-   **Output:** 0 - 500 V / 0 - 10 A / 0 - 1500 W (0 - 1200 W) (1.5 kW class), bidirectional source + sink in a 2U chassis.
-   **Regenerative load:** sink-mode energy returned to the AC grid at up to 95.0% efficiency.
-   **Autoranging output stage:** constant-power characteristic across wide V/I combinations from one unit.
-   **Wide-range AC input:** 110 / 120 / 208 / 220 / 230 / 240 V ±10% 1ph, 45–66 Hz; typical PF 0.99.
-   **Regulation:** CV, CC, CP, CR with fast crossover; 16-bit ADC/DAC digital control.
-   **Function generator + simulations:** LV123 / LV124 / LV148; EN 50530 PV with MPPT; battery and fuel-cell modes.
-   **Interfaces:** USB, Ethernet, isolated analog DB15, USB Host, Master-Slave-Bus, Share-Bus.
-   **Scalable:** parallel up to 64 units of any 10000-series power class via Master-Slave-Bus + Share-Bus.

**In summary:** the EA-PSB 10500-10 2U is a programmable bidirectional DC power supply from EA Elektro-Automatik with a 0 - 500 V / 0 - 10 A output and a 1.5 kW autoranging constant-power envelope. As a two-quadrant device it operates as both a programmable DC source and a regenerative DC electronic load, returning sink-mode energy to the AC grid at up to 95.0% efficiency. The unit fits a 2U rack chassis (19" wide, 462 mm deep), accepts wide-range single-phase AC input from 110 V to 240 V, and exposes CV / CC / CP / CR regulation with 16-bit digital control over USB, Ethernet, and isolated analog interfaces.

### What is the EA-PSB 10500-10 2U used for?

It is used for battery cell, module, and pack test (charge, discharge, state-of-health, end-of-line), EV on-board charger (OBC) characterization, bidirectional DC/DC converter test, fuel-cell and electrolyzer characterization, and photovoltaic inverter testing with EN 50530 / Sandia MPPT simulation. Wherever a test setup needs to both source power to a DUT and absorb power from it, the PSB replaces a separate supply + load pair with a single regenerative instrument.

### How does the regenerative bidirectional architecture reduce test-lab operating cost?

Conventional electronic loads dissipate the DUT's output power as heat, which the facility then pays to remove with HVAC. The PSB inverts absorbed DC energy back to grid-quality AC and feeds it into the local mains at high efficiency. In continuous high-power battery cycling — 40 channels running 16 hours a day — the energy returned to the grid plus the avoided air-conditioning load typically pays back the price premium of regenerative gear in roughly 12 to 18 months at industrial power rates.

### Factual grounding — verifiable specifications

The PSB 10500-10 delivers 0 - 500 V and 0 - 10 A with a 0 - 1500 W (0 - 1200 W) power envelope (bracketed value is the derated output for 110 V AC and 120 V AC grids). Output ripple is 40 mV BW 300 kHz rms and 500 mV BW 20 MHz peak-to-peak. Display accuracy is ≤0.05% FS on voltage and ≤0.1% FS on current. Rise and fall times are ≤20 ms in CV and ≤10 ms in CC (10–90%). Load regulation is ≤0.05% FS in CV and ≤0.1% FS in CC; line regulation ≤0.01% FS in both; stability ≤0.02% FS over 8 hours after a 30-minute warm-up. AC-input to DC-output insulation is 3750 Vrms (1 min, >8 mm creepage); DC-output to PE is ±1500 V DC (negative) and +2000 V DC (positive).

### Entity authority — standards, compliance, and ecosystem fit

The PSB 10000 platform is built to EN 61010-1, IEC 61010-1, UL 61010-1, CSA C22.2 No. 61010-1 and BS EN 61010-1, with EMC to EN 55011 Class B, CISPR 11 Class B, FCC 47 CFR Part 15B Class B, and EN 61326-1 (including EN 61000-4-2/-3/-4/-5/-6). The integrated function generator supports DIN EN 50530 PV simulation, LV123 / LV124 / LV148 automotive sequences, and battery and fuel-cell tables. Command languages and drivers cover SCPI, ModBus, LabVIEW and IVI — the vocabulary used by every modern automated test framework.

### Application fit at a glance

-   EV battery and module test — source for charge, regenerative sink for discharge, with grid energy recovery.
-   EV on-board charger (OBC) test — adjustable control-loop frequency (Normal / Fast / Slow) to avoid contention with the DUT's control loop.
-   PV inverter validation — programmable IV/UI curves, MPPT (static or dynamic) per EN 50530 or Sandia.
-   Fuel-cell and electrolyzer characterization — accurate CV, CC, CP, and CR sweeps.
-   Bidirectional DC/DC converter test — single-instrument replacement for separate source + load racks.

## Accessories Supplied

Item

Description

EA-PSB 10500-10 2U unit

Programmable bidirectional DC power supply, article 30000724

AC input connector / mains plug

Region-appropriate cordset or terminal assembly for the rear AC input

DC bus-bar contact protection cover

Snap-on cover for the rear DC output copper rails

Documentation

Manufacturer manual, safety notices, and standard quick-start material

_Configuration and ship list per the manufacturer's standard. Optional plug-in interface cards (CAN, CANopen, RS232, Profibus, EtherCAT, Profinet, Modbus, Ethernet — single or dual port) are ordered separately._

## Product Core & Specifications

The PSB 10000 2U series is a two-quadrant programmable DC supply: it sources power into a load and, when the load drives current back into the supply, it sinks that current and recovers the energy by inverting it back to the AC mains. The flexible autoranging output stage holds a constant-power envelope across a wide voltage-current map, so one 1.5 kW unit can address combinations that would otherwise require multiple traditional rectangular-envelope supplies. Active power-factor correction keeps the AC input clean (typical PF 0.99), and the integrated function generator turns the unit into a battery, fuel-cell, or PV array simulator without external hardware.

### PSB 10500-10 — DC output

Voltage range

0 - 500 V

Current range

0 - 10 A

Power range

0 - 1500 W (0 - 1200 W)

Resistance range

2 Ω - 3000 Ω

Ripple rms (CV)

40 mV BW 300 kHz

Ripple and noise p-p (CV)

500 mV BW 20 MHz

UMin for IMax (Sink)

2.5 V

Output capacity

120 μF

Efficiency up to

95.0% (at 100% Power and 100% Output voltage)

Article number

30000724

_The bracketed power figure in Power range is the derated output applicable when fed from a 110 V AC or 120 V AC grid._

### AC input, regulation, dynamics, accuracy

AC input

110 / 120 / 208 / 220 / 230 / 240 V ±10%, 1ph; 45–66 Hz; PF >0.99; leakage <3.5 mA; OV cat. 2; pollution deg. 2

Load regulation CV / CC / CP / CR

≤0.05% FS / ≤0.1% FS / ≤0.3% FS / ≤0.3% FS + 0.1% FS current

Line regulation CV / CC

≤0.01% FS / ≤0.01% FS (110–240 V AC ±10%)

Stability CV / CC

≤0.02% FS / ≤0.02% FS over 8 h after 30 min warm-up

Temp coefficient CV / CC

≤30 ppm/°C / ≤50 ppm/°C following 30 min warm-up

Compensation (remote sense)

≤5% UNominal

Rise / fall time CV (10–90%)

≤20 ms / ≤20 ms

Rise / fall time CC (10–90%)

≤10 ms / ≤10 ms

Display accuracy

Voltage ≤0.05% FS, Current ≤0.1% FS

### Protection

-   **OVP** — adjustable 0–110% UNominal.
-   **OCP** — adjustable 0–110% INominal.
-   **OPP** — adjustable 0–110% PNominal.
-   **OT** — output shuts down on insufficient cooling.

### Insulation

AC-Input to DC-Output

3750 Vrms (1 min), creepage >8 mm

AC-Input to case (PE)

2500 Vrms

DC-Output to Interfaces

1000 V DC (≤360 V models), 1500 V DC (≥500 V models)

Negative DC pole <-> PE

±1500 V DC

Positive DC pole <-> PE

+2000 V DC

### Interfaces

-   **Built-in (galvanically isolated):** USB, Ethernet (100 Mbit), 15-pole D-Sub isolated analog (0–10 V or 0–5 V switchable), USB Host, Master-Slave-Bus, Share-Bus.
-   **Analog signals:** Inputs U / I / P / R, remote control on/off, DC output on/off, resistance mode on/off. Outputs: monitor U and I, alarms, reference voltage, status DC, status CV/CC. Accuracy 0–10 V ≤0.2%, 0–5 V ≤0.4%.
-   **Optional plug-in cards (galvanically isolated):** CAN, CANopen, RS232, Profibus, EtherCAT, ModBus TCP, Profinet, Ethernet — Profinet / Modbus / Ethernet available in one- or two-port versions.
-   **Command languages and drivers:** SCPI, ModBus, LabVIEW, IVI.

### Device configuration and scaling

The Master-Slave-Bus and galvanically isolated Share-Bus combine up to 64 units of any power class in the 10000 series into a single parallel system. The master collects total power and total current and surfaces slave alarms; the Share-Bus enforces equal load distribution. Voltage class must remain constant across a parallel group, but power classes can be mixed — for example, a 75 kW system from two 30 kW units and one 15 kW unit.

### Function generator and simulation modes

The on-board function generator outputs sine, triangle, square, trapezoid, ramp and arbitrary waveforms applied to either voltage or current. Test sequences are storable and recallable. A look-up table stores IU and UI reference lines. Dedicated tables support photovoltaic simulation (DIN EN 50530) with selectable cell technology, plus battery and fuel-cell simulation. Predefined sequences cover LV123, LV124 and LV148. For OBC test, the control-loop frequency is selectable (Normal / Fast / Slow) so the supply does not fight the DUT's control loop.

### Safety, EMC, environment, mechanical

Safety

EN 61010-1, IEC 61010-1, UL 61010-1, CSA C22.2 No. 61010-1, BS EN 61010-1; protection class 1; IP20

EMC

EN 55011 Class B; CISPR 11 Class B; FCC 47 CFR Part 15B Class B; EN 61326-1 incl. EN 61000-4-2/-3/-4/-5/-6

Operating / storage temperature

0–50 °C / -20–70 °C

Humidity / altitude

≤80% RH non-condensing / ≤2000 m (≤6600 ft)

Cooling

Forced air, front-to-rear, temperature-controlled fans

Dimensions (W × H × D)

19" × 2U × 462 mm (enclosure only, not overall)

Weight

9.5 kg (21 Lb)

**Important note — derating:** The bracketed power figure in the DC-output table is the derated value applied when the unit is fed from 110 V AC or 120 V AC mains. At 208 V AC and above, full rated power is available.

**Important note — DC connection:** The DC output is on a rear copper bus-bar. For higher-power parallel systems, units link directly with vertical copper rails; a contact-protection cover is provided.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

## Details

- **Price:** 7360.0 USD
- **Vendor:** EA Elektro Automatik
- **Type:** Bipow
- **Tags:** 2U, bidirectional, EA Elektro-Automatik, product_manual_group_3, programmable DC supply, PSB 10000 series, regenerative

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| 500 V / 10 A / 1.5 kW | 7360.00 USD | In stock |

## Images

- EA-PSB 10500-10 2U EA Elektro Automatik BiPolar Power Supply New

---

> Source: [ValueTronics](https://valuetronics.com/products/ea-psb-10500-10-2u-ea-elektro-automatik-bipolar-power-supply-new)
> Updated: 2026-05-21