### Key Features at a Glance

-   **Frequency:** 9 kHz to 3.6 GHz
-   **Functions:** Spectrum analyzer, VNA, CAA, signal generator, power meter, EMI, modulation
-   **DANL:** -160 dBm/Hz typical (preamp on)
-   **SSB Phase Noise:** -95 dBc/Hz typ. at 1 GHz, 10 kHz offset
-   **RBW:** 1 Hz to 10 MHz
-   **VNA / CAA:** S11, S21, VSWR, return loss, cable loss, DTF
-   **Display:** 10.1 inch multi-touch, battery operation
-   **Remote:** SCPI / LabVIEW / IVI; LAN, USB, web browser

## About the Siglent SHA851A

In summary, the Siglent SHA851A is a handheld multi-function RF analyzer covering 9 kHz to 3.6 GHz, combining spectrum analyzer, vector network analyzer, cable-and-antenna analyzer, signal generator, power meter, EMI pre-compliance, and modulation analysis functions in a battery-powered field-portable enclosure. Per the datasheet, the SHA851A provides -160 dBm/Hz typical displayed average noise level with the preamplifier on, -95 dBc/Hz typical SSB phase noise at 1 GHz / 10 kHz offset, and a 10.1 inch capacitive multi-touch screen, on a single instrument that field service technicians can carry to a cell tower, antenna site, or remote installation.

### What is the Siglent SHA851A used for?

The SHA851A is used for field cellular site work, antenna and feedline characterization, transmitter verification, interference hunting, and EMI pre-compliance — applications that historically required a separate spectrum analyzer, VNA, cable-and-antenna analyzer, and signal generator. Per the datasheet, the SHA851A supports cable loss, return loss, VSWR, distance-to-fault (DTF), S-parameters (S11, S21), insertion loss, full two-port transmission measurement, channel power, ACPR, OBW, and CISPR 16-1-1 compliant EMI quasi-peak detection — on the same handheld instrument.

### How does the SHA851A compare to a benchtop spectrum analyzer?

A benchtop spectrum analyzer is optimized for a lab bench: AC mains, large display, deep specification depth, and (typically) better phase noise and dynamic range. A handheld instrument like the SHA851A is optimized for the field: battery operation, weather-tolerant enclosure, GPS receiver for site tagging, and integrated cable-and-antenna analyzer functions that lab instruments rarely include in a single chassis. Per the datasheet, the SHA851A delivers benchtop-class spectrum analyzer specifications — -160 dBm/Hz typical DANL, -95 dBc/Hz typical SSB phase noise, and 1 Hz to 10 MHz RBW — combined with field-grade VNA and CAA functions, on a battery-powered handheld designed for tower-crew and field-service work.

### Where does the SHA851A fit in a field RF kit?

-   Cellular site verification, tower-mounted antenna tests, and feedline characterization up to 3.6 GHz.
-   Distance-to-fault (DTF) measurement on coaxial feedlines to locate connector damage, water ingress, and feedline kinks.
-   Cable loss, return loss, VSWR, S11, and S21 measurements via the integrated vector network analyzer mode.
-   Spectrum monitoring for interference hunting and licensed-band verification, with GPS time and position stamping of captured signals.
-   EMI pre-compliance investigation at customer sites with CISPR 16-1-1 quasi-peak detection.
-   Field-service measurements that previously required carrying three or four separate instruments.

## Accessories Supplied

Per the manufacturer datasheet, the standard ship kit includes: a Quick Start guide, a battery pack, a region-appropriate AC adapter, and a carrying strap. A carrying case, calibration kit (for VNA / CAA operation), additional batteries, and RF cables / adapters are available as optional accessories from the manufacturer.

## Core Specifications

### Frequency, Reference, and Bandwidth

Frequency range

9 kHz to 3.6 GHz

Frequency resolution

1 Hz

Span range

0 Hz (Zero Span), 100 Hz to maximum frequency

Internal reference (10 MHz)

Aging < 1 ppm/yr; temperature stability < 1 ppm

GPS-disciplined reference

Yes, with optional GPS antenna

RBW (-3 dB)

1 Hz to 10 MHz, 1-3-10 sequence

VBW (-3 dB)

1 Hz to 10 MHz, 1-3-10 sequence

EMI filter (-6 dB)

200 Hz, 9 kHz, 120 kHz, 1 MHz (CISPR 16)

### Amplitude, Level, Phase Noise (Spectrum Analyzer Mode)

Measurement range (preamp off)

DANL to +30 dBm

Reference level

\-100 dBm to +30 dBm, 1 dB steps

Preamplifier

Approximately 20 dB nominal

Input attenuation

0 to 50 dB, 1 dB steps

Maximum continuous power

+30 dBm (1 W)

Maximum input DC voltage

± 50 VDC

Traces / detectors

4 / Pos-peak, Neg-peak, Sample, Normal, Average

DANL, preamp on (typ.)

\-160 dBm/Hz at 100 MHz

SSB phase noise at 1 GHz, 10 kHz offset

< -90 dBc/Hz; -95 dBc/Hz typical

Absolute amplitude accuracy at 50 MHz

± 0.5 dB

Third-order intercept (TOI)

+10 dBm typical

### Vector Network Analyzer / Cable-and-Antenna Mode

VNA / CAA frequency range

9 kHz to 3.6 GHz

Test ports

Two (N-type female)

Measurement parameters

S11 magnitude / phase, S21 magnitude / phase, VSWR, return loss, cable loss, distance-to-fault (DTF), Smith chart, group delay

Number of trace points

Up to 10001

Sweep types

Linear frequency, segment

Calibration types

OSL (Open / Short / Load), full two-port, normalization

Output power

\-45 dBm to 0 dBm, 1 dB steps

Dynamic range

\> 80 dB typical

Cable list (for DTF)

Pre-populated standard cable types editable by user

### Signal Generator, Power Meter, EMI, Modulation

Signal generator (option)

Internal source for stimulating DUTs; output level -45 dBm to 0 dBm

Power meter (option)

Compatible with USB power sensors for accurate absolute power measurement

EMI Measurement (option)

Peak, Average, Quasi-Peak detectors (CISPR 16-1-1); pre-loaded EN 55022, FCC Part 15 limit standards

Modulation Analysis (option)

AM, FM, ASK, FSK demodulation and quality measurement

Channel-power measurements

Channel Power, ACPR, OBW, T-Power, Harmonic, TOI

### Battery, Display, and General

Display

TFT LCD, 1280 × 800, 10.1 inch multi-touch capacitive

Battery operation

Lithium-ion battery pack, approximately 4 hours typical operation

Internal storage

≥ 8 GB

Dimensions (W×H×D, approx.)

330 × 220 × 90 mm

Weight (with battery, approx.)

approximately 3.4 kg (7.5 lb)

AC source (charger)

100-240 V, 50/60 Hz; auto-sensing

Operating temperature / humidity

\-10 to +50 °C; ≤ 90% RH at 30 °C, non-condensing

Enclosure

Field-tolerant chassis; not a fully sealed IP-rated unit — protect from sustained weather exposure

Safety / EMC / RoHS

EN 61010-1; EN 61326-1; 2011/65/EU

Remote interfaces

LAN, USB Device, USB Host; SCPI / LabVIEW / IVI; HTML5 web browser

#### Note on Calibration Kit Requirement

Cable, antenna, and VNA measurements on the SHA851A require a calibration kit appropriate to the test-port connector type. The calibration kit is NOT part of the standard ship kit and must be ordered separately. For N-type test ports, an N-type Open / Short / Load (OSL) calibration kit is typically required; SMA adapters and N-to-SMA precision adapters are also commonly needed. Confirm calibration kit requirements at the time of order.

#### Note on Optional Features

Several measurement modes — including signal generator, power meter, EMI Measurement, and Modulation Analysis — are software options that may be field-upgraded or factory-installed. Confirm at the time of order which options are required for the target application.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

## Details

- **Price:** 5589.0 USD
- **Vendor:** Siglent
- **Type:** Sig Ana
- **Tags:** Analyzers, Manufacturers, New, Siglent, Signal

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 5589.00 USD | In stock |

## Images

- SHA851A Siglent Signal Analyzer New

---

> Source: [ValueTronics](https://valuetronics.com/products/sha851a-siglent-signal-analyzer-new)
> Updated: 2026-05-21