# Keysight AC6802B 1000 VA Basic AC Power Source

# Keysight AC6802B 1000 VA Basic AC Power Source

## Key Features At A Glance

-   Single-phase AC output from 1–310 Vrms with 40–500 Hz frequency range across all models in the series
-   Power capacity from 500 VA to 4000 VA depending on model (AC6801B, AC6802B, AC6803B, AC6804B)
-   DC output mode available with voltage ranges to 438 V and corresponding current ratings per model
-   Built-in measurements include voltage, current, power, AC, DC, and AC+DC coupling
-   LAN/LXI Core and USB interfaces standard; optional GPIB interface available (Option AC68GPBU)
-   Remote setup, monitoring, and control via built-in Web server using a standard browser
-   Optional analog interface board (Option AC68BALGU) enables basic transient capability and external waveform input
-   Three-year warranted accuracy specifications with intuitive front-panel interface consistent with Keysight DC power supplies

The Keysight AC6800B Series is a family of basic AC power sources designed to deliver stable, dependable AC power for bench testing and production-line applications. The series comprises four single-phase models — the AC6801B at 500 VA, AC6802B at 1000 VA, AC6803B at 2000 VA, and AC6804B at 4000 VA — each providing AC output up to 310 Vrms with frequency selectable from 40 to 500 Hz, along with a DC output mode extending to 438 V.

Applications listed by the manufacturer include simulating global AC power conditions, testing varying frequency and voltage combinations to replicate real-world power environments, and power factor correction testing along with similar AC+DC applications such as evaluating input circuitry for ripple voltage. Typical use cases identified for the series include testing universal power supplies designed for global deployment, supplying single-phase 400 Hz power for avionic electronics development, manufacturing, and repair, and verifying commercial LED drivers and fluorescent ballasts at voltages up to 310 VAC — suitable for electronics rated to 277 VAC ±10%.

ValueTronics International, LLC operates a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where AC power source inventory is stored and tested before shipment. Unlike drop-ship resellers or pass-through brokers who never take physical possession of the instruments they list, ValueTronics handles every unit on-site — confirming functionality, verifying accessory completeness, and grading condition prior to listing. This in-house process is particularly relevant for programmable AC sources like the AC6800B Series, where the analog interface board option, GPIB interface board option, and rack-mount kit availability vary unit-to-unit and require physical verification rather than label inspection.

## Brand Heritage

Keysight Technologies originated as the test and measurement division of Hewlett-Packard, which spun off as Agilent Technologies in 1999 before further dividing in 2014 when the electronic measurement business became Keysight Technologies. AC6800B Series instruments carry the Keysight brand and reflect this engineering lineage in the family of bench AC sources, signal sources, and power supplies traceable to HP's original instrumentation work.

## Compare Other Models in This Series

The Keysight AC6800B Series consists of four single-phase basic AC power source models that share the same voltage range (1–310 Vrms AC, to 438 V DC), the same frequency range (40–500 Hz), the same measurement capabilities, and the same standard LAN/LXI Core and USB interfaces. The models differ primarily in maximum output power capacity and corresponding maximum rms current — allowing customers to select the appropriate VA rating for their device under test without changing the operating envelope, control interface, or measurement framework.

Across the series, the AC6801B at 500 VA serves single-device bench testing, the AC6802B at 1000 VA accommodates higher-current consumer electronics and ballast verification, the AC6803B at 2000 VA supports industrial loads, and the AC6804B at 4000 VA addresses the largest single-phase test applications within the family. All four models share the same accuracy specifications, the same optional analog interface board (AC68BALGU), the same optional GPIB interface (AC68GPBU), and the same compliance certifications.

Each new model in the AC6800B Series is listed on its own dedicated product page with model-specific pricing and availability. Use the comparison information below to identify which power capacity matches your device under test before navigating to the specific model page.

The primary differences across the four models are maximum output power, maximum rms current, and physical size. Voltage range, frequency range, AC and DC output modes, accuracy specifications, interface options, and protection features are identical across all four models. The AC6801B is the most compact at approximately 8 kg, while the AC6804B is approximately 31 kg and uses a different chassis form factor with four cooling fans to support its 4000 VA rating. Maximum repetitive peak current scales proportionally with model size, providing approximately three times the rms current rating in each case.

Input requirements also differ across models. The AC6801B uses an IEC 320 inlet and ships with a standard power cord (region-dependent), while the AC6802B, AC6803B, and AC6804B use M4 or M6 terminal blocks for input connections and do not include a power cord. Refer to the comparison table for the complete spec-by-spec breakdown including input current draw, output ratings, and physical dimensions for each model.

Model

Max Output Power

AC Voltage Range

Max RMS Current (Low/High)

**AC6802B**

1000 VA

155 Vrms / 310 Vrms

10 A / 5 A

AC6801B

500 VA

155 Vrms / 310 Vrms

5 A / 2.5 A

AC6803B

2000 VA

155 Vrms / 310 Vrms

20 A / 10 A

AC6804B

4000 VA

155 Vrms / 310 Vrms

40 A / 20 A

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Specification

AC6802B

Maximum output power

1000 VA (1 kVA)

Output phases

Single-phase

AC rated voltage range (low/high)

1 to 155 Vrms / 2 to 310 Vrms

AC maximum rms current (low/high)

10 A / 5 A

AC voltage setting accuracy

0.35% of full scale

Load power factor capability

0 to 1 (leading or lagging)

Frequency setting range

40 to 500 Hz

Frequency accuracy

± 0.02%

DC rated voltage range (low/high)

1.4 to 219 V / 2.8 to 438 V

DC maximum current (low/high)

8 A / 4 A

DC voltage setting accuracy

0.3% / 0.25% of full scale

DC maximum power

800 W

AC programmable voltage range

0 to 157.5 Vrms / 0 to 315 Vrms

Voltage setting resolution

0.1 V

Frequency setting resolution

0.1 Hz

Voltage THD

0.5% or less

Efficiency

70% or greater

AC maximum repetitive peak current

30 A / 15 A

DC programmable voltage range

\-222.5 to 222.5 V / -445 to 445 V

DC maximum repetitive peak current

24 A / 12 A

DC ripple noise

0.7 Vrms / 1.4 Vrms (typical)

Peak current measurement accuracy

± (2% of reading + 0.2 A / 0.1 A) (typical)

Nominal input rating

100 to 120 Vrms / 200 to 240 Vrms, 50 Hz or 60 Hz, single-phase

Input voltage range

90 to 132 Vrms / 180 to 264 Vrms (auto detected)

Input frequency range

47 Hz to 63 Hz

Input apparent power

1600 VA or less

Input current (at 100 V/200 V)

16 A / 8 A or less

Input current (at 120 V/230 V)

13.4 A / 7.0 A or less

Input terminal

M4 terminal block

Output terminal

M4 terminal block

Dimensions (W x H x D)

429 x 128 x 368 mm (16.9 x 5.0 x 14.5 in)

Weight

Approx. 11 kg (24.25 lb)

**Important:** Frequency-dependent specifications: voltage and current accuracy is specified as ±(0.5% of reading + offset) for 45 to 65 Hz and DC, but widens to ±(0.7% of reading + larger offset) for all other frequencies in the 40 to 500 Hz range. Confirm operating frequency requirements against the applicable accuracy specification before deployment.**Important:** Power cord is included only with the AC6801B. The AC6802B, AC6803B, and AC6804B do not include a power cord; an applicable power cord must be selected based on country of use.**Important:** Basic transient capability requires the optional analog interface card (Option AC68BALGU); not included with the base unit.**Important:** GPIB interface is optional (Option AC68GPBU); LAN/LXI Core and USB are standard.**Important:** EMC compliance applies only to models with CE marking on the panel. AC68xx models will not be in compliance with EMC limits unless the ferrite core is attached on the load wires.Recommended pairing: when sub-cycle transient simulation, harmonic generation, or arbitrary waveform output is required beyond the AC6800B's sinusoidal capability, the Keysight 6800C Series AC power source/analyzers with built-in arbitrary waveform generator provide source-and-analyze capability up to 1750 VA per the datasheet's referenced higher-performance option.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 7181.0 USD
- **Vendor:** Keysight
- **Type:** Ac Sources
- **Tags:** product_manual_group_3

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 7181.00 USD | In stock |

## Images

- AC6802B Keysight Technologies AC Source

---

> Source: [ValueTronics](https://value-tronics.myshopify.com/products/ac6802b-keysight-ac-source-new)
> Updated: 2026-05-30