# Keysight DSOX3102T 1 GHz InfiniiVision 3000T X-Series Oscilloscope

# Keysight DSOX3102T 1 GHz InfiniiVision 3000T X-Series Oscilloscope

## Key Features At A Glance

-   Bandwidth options from 100 MHz to 1 GHz across 2- and 4-channel models, with optional MSO upgrade adding 16 digital channels
-   5 GSa/s maximum sample rate (half channels) and up to 4 Mpts acquisition memory (half channels) powered by MegaZoom IV smart memory technology
-   Waveform update rate greater than 1,000,000 waveforms per second that holds under measurements, math, decode, and digital channels per datasheet update-rate table
-   8.5-inch capacitive touch display with gesture support and a designed-for-touch interface
-   Exclusive Zone Touch Trigger — draw a box on the display to isolate the signal of interest
-   Standard segmented memory and dedicated search/navigate for capturing and reviewing long acquisitions
-   7-in-1 integration: oscilloscope, optional digital channels, optional WaveGen 20 MHz function/arbitrary generator, optional frequency response analysis, standard 3-digit DVM, standard 8-digit counter/totalizer, and optional protocol decode
-   LAN, VGA, and GPIB connectivity available via plug-in modules; standard USB host and device ports

The Keysight InfiniiVision 3000T X-Series is a family of mixed-signal and digital-storage oscilloscopes built around an 8.5-inch capacitive touch display, a designed-for-touch user interface, and Keysight's MegaZoom IV smart memory technology. The series spans ten model configurations covering 100 MHz, 200 MHz, 350 MHz, 500 MHz, and 1 GHz bandwidth tiers, each available in 2-channel and 4-channel versions, with an optional MSO upgrade that adds 16 time-correlated digital channels. The datasheet positions the platform as a general-purpose oscilloscope that combines a touch-driven workflow with the discovery tools and analysis options needed to identify and resolve hard-to-find signal problems.

Per the datasheet, the 3000T X-Series is applied to hardware design and debug, embedded systems work involving serial buses such as I²C, SPI, UART, CAN, CAN FD, LIN, FlexRay, SENT, CXPI, MIL-STD 1553, ARINC 429, USB PD, and I²S, as well as power electronics characterization, frequency response (Bode) analysis of filters and switch-mode power supply loop response, mask and limit testing, and HDTV/enhanced video triggering and analysis. The 7-in-1 integration places oscilloscope channels, optional MSO digital channels, an optional 20 MHz WaveGen function/arbitrary generator, optional frequency response analysis, a standard 3-digit DVM, a standard 8-digit counter and totalizer, and optional protocol analysis into a single instrument.

ValueTronics keeps Keysight InfiniiVision 3000T X-Series oscilloscopes and the surrounding accessory ecosystem — passive and active probes, current and differential probes, the N7020A power rail probe, MSO cables, rack kits, and calibration documentation — stocked and managed at our 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every {{CONDITION}} instrument routed through Elgin is handled by our in-house team rather than drop-shipped from a third party, so the unit you order is the unit our technicians have physically had in front of them. That direct handling is what separates a verified instrument purchase from a pass-through broker transaction.

## Brand Heritage

Keysight Technologies is the present-day home of the test and measurement business that originated at Hewlett-Packard. HP spun out its measurement businesses as Agilent Technologies in 1999, and Agilent in turn separated its electronic measurement operations into Keysight Technologies in 2014. Oscilloscopes branded HP, Agilent, and Keysight share a continuous engineering and product-line heritage across that history.

## Compare Other Models in This Series

The InfiniiVision 3000T X-Series is a ten-configuration oscilloscope family that scales across five bandwidth tiers — 100 MHz, 200 MHz, 350 MHz, 500 MHz, and 1 GHz — with each tier available in 2-channel and 4-channel form. Every model in the family shares the same MegaZoom IV smart memory architecture, the 8.5-inch capacitive touch display, the designed-for-touch user interface, and the Zone Touch Trigger described in the datasheet. The differences between models are concentrated in bandwidth, calculated rise time, and the timebase range, while sample rate (5 GSa/s half channels, 2.5 GSa/s all channels), maximum memory depth (4 Mpts half channels, 2 Mpts all channels), and waveform update rate (>1,000,000 wfm/s) are constant across the series.

Each base model can be expanded along three axes the datasheet documents explicitly: an MSO upgrade adds 16 digital channels, a WaveGen upgrade adds the 20 MHz function/arbitrary waveform generator, and a set of bandwidth upgrades (license-only between adjacent tiers up to 500 MHz, or return-to-Keysight service for upgrades reaching 1 GHz) lets the same chassis grow into a higher-bandwidth model. Application software for embedded, automotive, aerospace, power, and NFC analysis is delivered as separately licensed packages and adds the corresponding decode, trigger, and analysis capability to the base instrument.

Each new 3000T X-Series model linked below is its own product page with condition-matched pricing and inventory. The product pages share this family overview because the architecture, update rate, MegaZoom memory behavior, and capacitive touch workflow are identical across the series — the per-model pages carry the specific bandwidth, channel count, calculated rise time, timebase range, and installed options applicable to that configuration.

Across the series, the datasheet specifies bandwidth and calculated rise time as follows: the 3012T/3014T at 100 MHz with a calculated rise time of ≤3.5 ns, the 3022T/3024T at 200 MHz with ≤1.75 ns, the 3032T/3034T at 350 MHz with ≤1 ns, the 3052T/3054T at 500 MHz with ≤700 ps, and the 3102T/3104T at 1 GHz with ≤450 ps. Timebase range scales with bandwidth as well: 5 ns/div minimum on 100 MHz models, 2 ns/div on 200 MHz models, 1 ns/div on 350 and 500 MHz models, and 500 ps/div on 1 GHz models, with all models extending out to 50 s/div. On 1 GHz models, the 50 Ω input sensitivity range is 1 mV/div to 1 V/div, versus 1 mV/div to 5 V/div on lower-bandwidth models.

The 2-channel vs. 4-channel choice and the optional MSO upgrade together determine total observable signals: a 2-channel DSO provides two analog channels, a 4-channel DSO provides four, and an MSO version of either adds 16 digital channels (D0–D15) for time-correlated mixed-signal acquisition. All other capabilities — Zone Touch Trigger, segmented memory, search/navigate, frequency response analysis (optional), gated FFT, the 38 automatic measurements, advanced math, the standard DVM and counter/totalizer, and the WaveGen option — are available across the series regardless of bandwidth or channel count. The comparison table on the family product page summarizes bandwidth, calculated rise time, channel count, and MSO availability for each model so the buyer can match application bandwidth requirements to the correct tier.

Model

Bandwidth

Analog Channels

Digital Channels

**DSOX3102T**

1 GHz

2

0

DSOX3012T

100 MHz

2

0

DSOX3014T

100 MHz

4

0

MSOX3012T

100 MHz

2

16

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   N2843A Passive probe 500 MHz 10:1 attenuation (1 per channel)
-   Localized power cord and overlay
-   Documentation CD containing localized user's guide, service guide, and programmer's manual
-   Certificate of calibration

## Product Core & Specifications

Category

Specification

Value

Acquisition

Maximum sample rate

5 GSa/s half channels, 2.5 GSa/s all channels

Acquisition

Maximum memory depth

4 Mpts half channels, 2 Mpts all channels

Acquisition

Maximum digital channel sample rate

1.25 GSa/s all pods

Acquisition

Maximum digital channel record length

2 Mpts (with digital channels only)

Acquisition

Acquisition modes

Normal, Peak detect, Averaging (2 to 65,536), High resolution (12 bits), Segmented (max 1000 segments), Digitizer

Display

Display

8.5-inch capacitive touch/gesture enabled TFT LCD

Display

Resolution

800 (H) x 480 (V) pixel format

Display

Graticules

8 vertical divisions by 10 horizontal divisions

Display

Format

YT, XY, and Roll

Display

Maximum waveform update rate

\> 1,000,000 wfms/s

Display

Persistence

Off, infinite, variable persistence (100 ms to 60 s)

Display

Intensity gradation

64 intensity levels

Vertical (Analog)

Hardware bandwidth limits

Approximately 20 MHz (selectable)

Vertical (Analog)

Input coupling

AC, DC

Vertical (Analog)

Input impedance

Selectable: 1 MΩ ± 1% (14 pF), 50 Ω ± 1.5%

Vertical (Analog)

Vertical resolution

8 bits (12 bits with averaging)

Vertical (Analog)

Maximum input voltage

135 Vrms; 190 Vpk

Vertical (Analog)

DC vertical gain accuracy

± 2.0% full scale

Vertical (Analog)

DC vertical offset accuracy

± 0.1 div ± 2 mV ± 1% of offset setting

Vertical (Analog)

Channel-to-channel isolation

\> 100:1 from DC to maximum specified bandwidth

Vertical (Analog)

Offset range

± 2 V (1 mV/div to 200 mV/div); ± 50 V (> 200 mV/div to 5 V/div)

Vertical (Digital)

Digital input channels

16 digital (D0 to D15)

Vertical (Digital)

Threshold selections

TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (–1.3 V), user-defined (selectable by pod)

Vertical (Digital)

User-defined threshold range

± 8.0 V in 10 mV steps

Vertical (Digital)

Maximum input voltage

± 40 V peak CAT I

Vertical (Digital)

Threshold accuracy

± (100 mV + 3% of threshold setting)

Vertical (Digital)

Maximum input dynamic range

± 10 V about threshold

Vertical (Digital)

Minimum voltage swing

500 mVpp

Vertical (Digital)

Input impedance

100 kΩ ± 2% at probe tip

Vertical (Digital)

Input capacitance

~8 pF

Horizontal

Time base accuracy

± 1.6 ppm + aging factor (1st year: ± 0.5 ppm)

Horizontal

Time base delay range (pre-trigger)

Greater of 1 screen width or 250 μs

Horizontal

Time base delay range (post-trigger)

1 s to 500 s

Horizontal

Channel-to-channel deskew range

± 100 ns

Horizontal

Modes

Main, Zoom, Roll, XY

Horizontal (Digital)

Minimum detectable pulse width

5 ns

Horizontal (Digital)

Channel-to-channel skew

2 ns (typical); 3 ns (maximum)

Trigger

Trigger sources

Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen

Trigger

Trigger modes

Normal, Auto, Single, Force

Trigger

Trigger coupling

DC, AC, HF reject, LF reject, Noise reject

Trigger

Trigger holdoff range

40 ns to 10.00 s

Trigger

Internal trigger sensitivity

< 10 mV/div: Greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div

Trigger

Trigger level range (any channel)

± 6 div from center screen

**Important:** Use this instrument only for measurements within its specified measurement category. The 3000T X-Series is not rated for CAT II, III, or IV, and the datasheet states no transient overvoltage is allowed. Maximum input voltage on the analog channels is 135 Vrms / 190 Vpk; higher voltages require an appropriately rated probe such as the included N2843A 10:1 probe (rated for testing up to 300 Vrms).**Important:** Use this instrument only for measurements within its specified measurement category (not rated for CAT II, III, IV). No transient overvoltage allowed.**Important:** Maximum input voltage on analog channels: 135 Vrms; 190 Vpk. Probing technology allows testing of higher voltages — for example, the included N2843A 10:1 probe supports testing up to 300 Vrms.**Important:** Maximum input voltage on digital channels: ± 40 V peak CAT I.**Important:** The 3000T X-Series comes with a one-time 30-day, all-optional-features trial license. Individual optional feature 30-day trial licenses can also be redeemed at www.keysight.com/find/30daytrial.Recommended pairing: when making power-integrity measurements such as DC rail ripple, noise, and high-frequency transients with mV sensitivity on top of a large DC offset, the datasheet identifies the Keysight N7020A Power Rail Probe (2 GHz, 1:1, ±24 V offset range) as the matching accessory for the 3000T X-Series.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 16919.0 USD
- **Vendor:** Keysight
- **Type:** Ms Oscilloscope
- **Tags:** Digital, Keysight, Keysight Technologies, Manufacturers, Oscilloscopes, product_manual_group_3, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 16919.00 USD | In stock |

## Images

- DSOX3102T Keysight Technologies Digital Oscilloscope

---

> Source: [ValueTronics](https://valuetronics.com/products/dsox3102t-keysight-digital-oscilloscope-new)
> Updated: 2026-05-30