# Fluke Networks FI-1000-KIT FiberInspector USB Video Probe Kit

# Fluke Networks FI-1000-KIT FiberInspector USB Video Probe Kit

## Key Features At A Glance

-   Multimode (850/1300 nm) and singlemode (1310/1550 nm) coverage in a single quad-wavelength OTDR for enterprise and data center fiber certification
-   Event dead zone of 0.5 m typical at 850 nm and attenuation dead zone of 2.5 m typical at 850 nm for resolving closely spaced events on patch-cord-dense links
-   DataCenter OTDR mode auto-configures pulse widths and end-detection for short, connector-rich links without manual tuning
-   Test times as short as 2 seconds per wavelength at 850 nm in Quick Test mode for high-throughput certification workflows
-   Distance measurement range up to 130 km at 1550 nm and dynamic range up to 32 dB typical at 1310 nm
-   Graphical EventMap view, capacitive touchscreen Taptive user interface, and built-in 650 nm Class II VFL for visual fault location
-   ProjX project management with LinkWare and LinkWare Live for test result consolidation, dashboard visibility, and professional report generation
-   Optional FiberInspector Pro video probe integration for IEC-style endface inspection alongside OTDR results

The Fluke Networks OptiFiber Pro is a Tier 2 (extended) fiber certification OTDR within the Versiv Cabling Certification platform, purpose-built for enterprise networks and data centers rather than long-haul carrier deployments. The product family includes multimode, singlemode, and quad-wavelength configurations that share the Taptive capacitive touchscreen interface, the ProjX project management system, and LinkWare reporting software. The datasheet positions the instrument as a fiber troubleshooting and certification tool for IT infrastructure administrators, SAN designers, cable installers, and network engineers working on 40G and 100G data center cabling.

Listed applications include certifying fiber performance against industry and customer-specific standards, troubleshooting data center fiber links with short patch cables and many connectors, characterizing connectors, splices, and high-loss regions through the graphical EventMap view, and inspecting fiber endfaces inside ports or patch cords when paired with the FiberInspector Pro video probe. The DataCenter OTDR mode is called out for short, connector-rich links where conventional carrier-class OTDR settings would be ineffective, and the SmartLoop OTDR feature enables automated testing and analysis of two fibers in a single test from one end of the link.

ValueTronics International stores and tests every {{CONDITION}} OptiFiber Pro unit in our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois — the same facility where every Versiv-platform instrument we ship is inspected, functionally verified, and prepared for delivery. We are not a drop-shipper or a pass-through listing service: the technician who powers up the OFP-100-Q quad module and confirms multimode and singlemode operation works in the same building where the unit is racked, packed, and shipped from.

## Brand Heritage

Fluke Networks operates as part of Fluke Corporation, with cabling certification and network test products distributed worldwide. The OptiFiber Pro is part of the Versiv platform, which also includes copper certification, OLTS, and Wi-Fi analysis modules sharing the Taptive interface and LinkWare software ecosystem.

## Compare Other Models in This Series

The OptiFiber Pro family is sold in three primary OTDR configurations: a multimode-only module (OFP-100-M / OFP-MM), a singlemode-only module (OFP-100-S / OFP-SM), and the quad module (OFP-100-Q) that combines both wavelength sets in one instrument. Each base configuration is also available with the FiberInspector video probe bundled in a kit form (OFP-100-MI, OFP-100-SI, OFP-100-QI).

All three OTDR configurations share the same Versiv mainframe, Taptive touchscreen interface, ProjX project management, LinkWare and LinkWare Live software ecosystem, and built-in 650 nm VFL. They differ in which fiber types and wavelengths they can test natively, which determines whether a single unit can certify a mixed multimode and singlemode plant or whether two instruments (or a module swap) is required.

Each model below links to its own dedicated product page with new pricing and current inventory. Module variants and full kits (with or without the FiberInspector video probe) are listed separately so the configuration ordered matches the application.

The OFP-100-Q quad configuration covers all four wavelengths (850 nm, 1300 nm, 1310 nm, 1550 nm) and both fiber type families (50/125 µm and 62.5/125 µm multimode, plus singlemode) in a single module. For environments that test both multimode data center cabling and singlemode building backbones or campus runs, the quad module avoids the need to carry two instruments or swap modules between jobs.

The multimode module covers 850 nm and 1300 nm on 50/125 µm and 62.5/125 µm fiber, with a 40 km maximum distance range setting. The singlemode module covers 1310 nm and 1550 nm with a 130 km maximum distance range setting. The quad module combines both wavelength and fiber-type coverage with the same dead zone, dynamic range, and pulse width specifications as the dedicated single-band modules at their respective wavelengths.

Selecting between configurations is primarily a function of plant composition: a multimode-only data center bench is well served by the OFP-100-M kit, a singlemode-focused outside-plant or campus role by the OFP-100-S kit, and any environment with mixed multimode and singlemode certification work by the OFP-100-Q quad. Refer to the comparison table that follows for wavelength, distance range, and dead-zone specifications across the three modules.

Model

Module Type

Wavelengths

Max Distance Range

**FI-1000-KIT**

FiberInspector Probe Kit

—

—

OFP-100-M

Multimode

850 nm, 1300 nm

40 km

OFP-100-MI

Multimode

850 nm, 1300 nm

40 km

OFP-100-S

Singlemode

1310 nm, 1550 nm

130 km

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   FI-1000 FiberInspector USB video probe
-   LC bulkhead tip
-   FC/SC bulkhead tip
-   1.25 mm universal tip
-   2.5 mm universal tip

## Product Core & Specifications

Specification

Multimode Module

Singlemode Module

Quad Module

Wavelengths

850 nm +/- 10 nm; 1300 nm +35/-15 nm

1310 nm +/- 25 nm; 1550 nm +/- 30 nm

850 nm +/- 10 nm, 1300 nm +35/-15 nm, 1310 nm +/- 25 nm, 1550 nm +/- 30 nm

Compatible fiber types

50/125 µm, 62.5/125 µm

Singlemode

50/125 µm, 62.5/125 µm, Singlemode

Event dead zone

850 nm: 0.5 m (typical); 1300 nm: 0.7 m (typical)

1310 nm: 0.6 m (typical); 1550 nm: 0.6 m (typical)

850 nm: 0.5 m, 1300 nm: 0.7 m, 1310 nm: 0.6 m, 1550 nm: 0.6 m (typical)

Attenuation dead zone

850 nm: 2.5 m (typical); 1300 nm: 4.5 m (typical)

1310 nm: 3.6 m (typical); 1550 nm: 3.7 m (typical)

850 nm: 2.5 m, 1300 nm: 4.5 m, 1310 nm: 3.6 m, 1550 nm: 3.7 m (typical)

Dynamic range

850 nm: 28 dB; 1300 nm: 30 dB (typical)

1310 nm: 32 dB; 1550 nm: 30 dB (typical)

850 nm: 28 dB, 1300 nm: 30 dB, 1310 nm: 32 dB, 1550 nm: 30 dB (typical)

Max distance range setting

40 km

130 km

MM: 40 km, SM: 130 km

Distance measurement range

850 nm: 9 km; 1300 nm: 35 km

1310 nm: 80 km; 1550 nm: 130 km

850 nm: 9 km, 1300 nm: 35 km, 1310 nm: 80 km, 1550 nm: 130 km

Reflectance range

850 nm: -14 dB to -57 dB; 1300 nm: -14 dB to -62 dB (typical)

1310 nm: -14 dB to -65 dB; 1550 nm: -14 dB to -65 dB (typical)

850 nm: -14 dB to -57 dB, 1300 nm: -14 dB to -62 dB, 1310 nm: -14 dB to -65 dB, 1550 nm: -14 dB to -65 dB (typical)

Sample resolution

3 cm to 400 cm

3 cm to 400 cm

3 cm to 400 cm

Pulse widths (nominal)

850 nm: 3, 5, 20, 40, 200 ns; 1300 nm: 3, 5, 20, 40, 200, 1000 ns

3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns

850 nm: 3, 5, 20, 40, 200 ns; 1300 nm: 3, 5, 20, 40, 200, 1000 ns; 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns

### FiberInspector Probe Specifications

Magnification

~ 200X with OptiFiber Pro Display

Light source

Blue LED

Power source

TFS mainframe

Field of View (FOV)

Horizontal: 425 µm, Vertical: 320 µm

Minimum detectable particle size

0.5 µm

Dimensions

Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip

Weight

200 g

Temperature range

Operating: 32°F to 122°F (0 °C to +50 °C); Storage: -4°F to +158°F (-20°C to +70°C)

### VFL Specifications

On/Off control

Mechanical switch and a button on the touch screen

Output power

316 µW (-5 dBm) ≤ peak power ≤ 1.0 mW (0 dBm)

Operating wavelength

650 nm nominal

Spectral width (RMS)

±3 nm

Output modes

Continuous wave; Pulsed mode (2 Hz to 3 Hz blink frequency)

Connector adapter

2.5 mm universal

Laser safety (classification)

Class II CDRH, Complies to EN 60825-2

### General Specifications

Weight

Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)

Dimensions

Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)

Battery

Lithium ion battery pack, 7.2 volts

Battery life

8 hr Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber

Charge Time (Tester off)

4 hours to charge from 10% to 90% capacity

Charge Time (Tester on)

6 hours to charge from 10% to 90% capacity with the tester on

### Environmental Specifications

Operating temperature

\-18ºC to 45ºC (using battery power; with AC power: 0ºC to 45ºC)

Non-operating temperature

\-30ºC to 60ºC

Operating altitude

4,000 m (13,123 ft); 3,200 m (10,500 ft) with AC adapter

Storage altitude

12,000 m

EMC

EN 61326-1

**Important:** DataCenter OTDR mode and Quick Test mode test times of 2 seconds per wavelength apply at 850 nm multimode; singlemode Quick Test is 5 seconds per wavelength typical.**Important:** Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.**Important:** Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.**Important:** Launch cables, test reference cords, and connector adapters are sold separately and must be selected according to the connector type and fiber type of the link under test (see ordering accessories list).**Important:** For complete kit configurations, please visit www.flukenetworks.com/orderopro.Recommended pairing: pair the OptiFiber Pro with the FI-1000 FiberInspector USB video probe (or order the OFP-100-QI kit that bundles it) so OTDR traces and IEC-style endface inspection results can be captured in the same certification report.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 2710.23 USD
- **Vendor:** Fluke Networks
- **Type:** Data Log
- **Tags:** Datacom, Fiber, Fluke Networks, Manufacturers, Other Equipment, product_manual_group_3, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 2710.23 USD | In stock |

## Images

- FI-1000-KIT Fluke Networks Fiber

---

> Source: [ValueTronics](https://valuetronics.com/products/fi-1000-kit-fluke-networks-fiber-new)
> Updated: 2026-05-30