# TESCOM TC-5060B UHF TEM Cell, 100 MHz to 3 GHz (Pre-Owned)

# TESCOM TC-5060B UHF TEM Cell, 100 MHz to 3 GHz (Pre-Owned)

## Key Features At A Glance

-   Broadband TEM cell operation up to 3 GHz for radiation and susceptibility testing
-   Effective shielding greater than 80 dB up to 2 GHz, greater than 70 dB from 2 GHz to 3 GHz
-   Compact desktop footprint at 344(W) x 380(D) x 675(H) mm, 19 kg
-   Effective cell height of 220 mm with 13 dBuV/m field strength at test point per 1 uV input
-   Typical path loss of 22 dB across the operating band
-   DB25 data connector and SMA RF connector for device interfacing; Type-N RF port for instrument connection
-   Door opening of 176(W) x 130(H) mm sized for mobile phones and small wireless devices

The TESCOM TC-5060A/B is an economy UHF TEM cell designed to generate a consistent electromagnetic field for testing small RF devices. An external test signal applied through the input port produces a predictable TEM test field inside the cell, while radiation from a device transmitting inside the cell can be detected through the same port using a test receiver. The compact, economical design is optimized for medium-accuracy measurements beyond the standard TEM cell frequency range.

Applications listed for the TC-5060A/B include receiver sensitivity testing, transmitter radiated power testing, and EMI and EMS tests for small UHF devices. Target device categories include mobile phones, W-LAN, PDA, Bluetooth, and DAB/DMB equipment. The cell is specifically designed for all types of mobile phones and accommodates pagers, GPS receivers, and similar small wireless products in its 176 mm by 130 mm door opening.

## Compare Other Models in This Series

The TC-5060 family consists of two compact desktop UHF TEM cells, the TC-5060A and TC-5060B, sharing identical mechanical dimensions, shielding performance, path loss, cell height, and field strength characteristics. Both units use the same DB25 data interface, the same N(f) outside / SMA(f) inside RF connector arrangement, and the same 176 x 130 mm door opening sized for mobile phones and similar small wireless devices.

The two variants differ in their specified VSWR frequency coverage and in supplied accessories. The TC-5060B extends specified VSWR performance to lower frequencies and includes an additional SMA 50-ohm termination in the accessory kit. Selection between the two models is driven by the lowest test frequency required for the intended application.

Each pre-owned TC-5060 series unit listed below is its own product page with condition-matched pricing, accessory verification, and the appropriate documentation noted on that listing. Click through to the specific model that matches your VSWR frequency requirement.

The principal documented difference between the TC-5060A and TC-5060B is the specified VSWR frequency range. The TC-5060A is rated for VSWR less than 1.7 from 400 MHz to 3 GHz, while the TC-5060B extends that VSWR specification down to 100 MHz, also rated less than 1.7 up to 3 GHz. Applications that include testing below 400 MHz, such as certain VHF/low-UHF wireless or paging frequencies, are addressed by the TC-5060B.

Supplied accessories also differ between the two models. Both units ship with the 4003-0005 DB25 data cable and the 4006-0002 N-type RF cable. The TC-5060B additionally includes a 1901-0002 SMA 50-ohm termination, listed in the datasheet as supplied with the TC-5060B only. Mechanical dimensions, weight, shielding, path loss, cell height, field strength, and door size are common to both models per the published specifications.

Model

Frequency Range (VSWR < 1.7)

Path Loss

Effective Cell Height

**TC-5060B**

100 MHz to 3 GHz

22 dB typical

220 mm

TC-5060A

400 MHz to 3 GHz

22 dB typical

220 mm

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   4003-0005, DB25(p) to DB25(s) cable, 1 m, 1 pc.
-   4006-0002, N(m) to N(m) cable, 2 m, 1 pc.
-   1901-0002, SMA 50 ohm Termination, 1 pc.

## Product Core & Specifications

Specification

Value

VSWR (TC-5060A)

< 1.7, 400 MHz to 3 GHz

VSWR (TC-5060B)

< 1.7, 100 MHz to 3 GHz

Path Loss

22 dB typical

Effective Shielding

\> 80 dB up to 2 GHz; > 70 dB 2 GHz to 3 GHz

Effective Cell Height

220 mm

Field Strength at Test Point

13 dBuV/m at 1 uV input

Data Connector

DB25(p) outside, DB25(s) inside

RF Connector

N(f) outside, SMA(f) outside and SMA(f) inside

Dimensions (W x D x H)

344 x 380 x 675 mm

Door Size (W x H)

176 x 130 mm

Weight

19 kg

**Important:** VSWR coverage differs by model: TC-5060A is specified from 400 MHz to 3 GHz; TC-5060B extends down to 100 MHz to 3 GHz. The TC-5060B is also supplied with an SMA 50-ohm termination not included with the TC-5060A.**Important:** Specifications are subject to change without prior notice.**Important:** DUT mounting fixtures (F5060-10, F5060-20, F50603A) are ordered separately and are not included with the base TC-5060A/B UHF TEM Cell.Typical pairing: connect the Type-N RF port to a CDMA tester, GSM tester, spectrum analyzer, or signal generator per the datasheet test configuration, with the DUT mounted inside on an optional F5060-series fixture sized to the device.

## About this used unit

-   Warranty included
-   Functional verification included
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** TESCOM
- **Type:** Fixture
- **Tags:** EMI, Manufacturers, Other Equipment, product_manual_group_3, Product_used, Tescom

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- TESCOM TC-5060B UHF TEM Cell, 100 MHz to 3 GHz (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/tc-5060b-tescom-emi-equipment-used)
> Updated: 2026-05-30