# Anritsu MS9740A Optical Spectrum Analyzer, 600 nm to 1750 nm (Pre-Owned)

# Anritsu MS9740A Optical Spectrum Analyzer, 600 nm to 1750 nm (Pre-Owned)

## Key Features At A Glance

-   Wavelength measurement range from 600 nm to 1750 nm covering visible through extended telecom bands
-   Wavelength sweep time under 0.2 seconds at 5 nm span for high-throughput production test
-   Dynamic range of 42 dB at 0.2 nm from peak and 58 dB at 0.4 nm from peak (Normal mode) for WDM signal evaluation
-   Minimum wavelength resolution of 30 pm with ±20 pm wavelength accuracy (1520 nm to 1620 nm with wavelength calibration light source)
-   Nine application measurement modes: DFB-LD, FP-LD, LED, PMD, Opt. Amp, Opt. Amp Multi-channel, WDM, LD Module, and WDM Filter
-   Ethernet (TCP/IP) standard and GPIB optional interfaces for ATE and remote-control integration
-   8.4-inch SVGA color LCD with dedicated front-panel function keys and embedded Windows OS
-   Compact bench-top form factor at approximately 15 kg with under 75 VA power consumption

The Anritsu MS9740A is a bench-top optical spectrum analyzer covering 600 nm to 1750 nm, designed for evaluation of active optical devices including LD modules, DFB-LDs, FP-LDs, LEDs, optical amplifiers, WDM signals, and optical bandpass filters. The instrument combines high-speed waveform sweeping with eight integrated analysis menus to support both production-line throughput and engineering characterization workflows.

Anritsu positions the MS9740A for evaluation of active optical devices such as SFP, XFP, and SFP+ transceiver modules, as well as VCSEL and DFB optical sources. The datasheet also identifies applications in WDM signal evaluation at 100 GHz and 50 GHz channel spacing, EDFA gain and noise figure characterization, PMD measurement of optical fiber, and analysis of optical bandpass filters including WSS and WDM filter devices. Combined with a Bit Error Rate Tester, the analyzer supports spectrum analysis of optical transceiver outputs and WDM signals.

## Brand Heritage

Anritsu Corporation is a Japanese precision measurement company with roots stretching to 1895. Anritsu's optical and RF test portfolio was significantly expanded by its 1993 acquisition of Wiltron Company, which added RF and microwave measurement technology and North American commercial presence to the Anritsu lineup.

## Accessories Supplied

-   MS9740A Operation Manual (CD): 1 pc
-   Power Cord: 1 pc

## Product Core & Specifications

Parameter

Specification

Supported Optical Fiber

SM fiber (ITU-T G.652), 50 µm/125 µm GI fiber, PC Connector (reflection attenuation 40 dB or more)

Optical Connector

User replaceable: FC, SC, ST, DIN (All connectors are PC polished.)

Wavelength Measurement Range

600 nm to 1750 nm

Wavelength Accuracy

±20 pm (1520 nm to 1620 nm, Resolution: 0.03 nm to 0.2 nm), ±100 pm (1520 nm to 1620 nm, Resolution: 0.5 nm, 1.0 nm); ±300 pm (600 nm to 1520 nm), ±200 pm (1520 nm to 1570 nm), ±300 pm (1570 nm to 1750 nm)

Wavelength Stability

±5 pm (1 min, smoothing: 11 pt, at center wavelength of half maximum, Using SM fiber)

Wavelength Linearity

±20 pm (1520 nm to 1620 nm)

Setting Resolution

0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0 nm (0.03 nm, 0.05 nm only 1550 nm band and room temperature)

Resolution Accuracy

±7% (Resolution: 0.1 nm), ±3% (Resolution: 0.2 nm), ±2.2% (Resolution: 0.5 nm) \[1520 nm to 1620 nm\]; ±30% (Resolution: 0.1 nm), ±15% (Resolution: 0.2 nm), ±7% (Resolution: 0.5 nm) \[600 nm to 1520 nm, 1620 nm to 1750 nm\]

Measurement Range (5° to 30°C, Optical Att: Off)

\-65 to +10 dBm (600-1000 nm), -85 to +10 dBm (1000-1250 nm), -90 to +10 dBm (1250-1600 nm), -85 to +10 dBm (1600-1650 nm), -65 to +10 dBm (1650-1700 nm), -55 to +10 dBm (1700-1750 nm)

Measurement Range (30° to 45°C, Optical Att: Off)

\-60 to +10 dBm (600-1000 nm), -80 to +10 dBm (1000-1250 nm), -85 to +10 dBm (1250-1600 nm), -80 to +10 dBm (1600-1650 nm), -60 to +10 dBm (1650-1700 nm), -50 to +10 dBm (1700-1750 nm)

Measurement Range (Optical Att: On)

\-70 to +23 dBm (1100-1600 nm) \[5° to 30°C\]; -65 to +23 dBm (1100-1600 nm) \[30° to 45°C\]

Level Accuracy

±0.4 dB (Wavelength: 1310 nm, 1550 nm, Input: -10 dBm, Resolution: 0.1 nm to 1.0 nm)

Level Stability

±0.02 dB (1 min, Wavelength: 1550 nm, Input: -23 dBm, Resolution: 0.1 nm to 1.0 nm, no polarization fluctuation)

Level Linearity

±0.05 dB (Wavelength: 1550 nm, Input: -50 to 0 dBm, Optical Att: Off); ±0.05 dB (Wavelength: 1550 nm, Input: -30 to +20 dBm, Optical Att: On)

Level Flatness

±0.1 dB (Wavelength: 1520 nm to 1620 nm, Resolution: 0.5 nm, Optical Att: Off)

Polarization Dependency

±0.05 dB (Wavelength: 1550 nm/1600 nm), ±0.1 dB (Wavelength: 1310 nm), \[Resolution: 0.5 nm, 1.0 nm\]

Dynamic Range

High dynamic range: 70 dB (1 nm from peak), 60 dB (0.4 nm from peak), 42 dB (0.2 nm from peak); Normal dynamic range: 62 dB (1 nm from peak), 58 dB (0.4 nm from peak), 42 dB (0.2 nm from peak) \[Wavelength: 1550 nm, Resolution: 0.05 nm, Optical Att: Off, 20° to 30°C\]

Optical Return Loss

≥35 dB (Using SM fiber with wavelength of 1300 nm and 1550 nm)

Sweep Width

0.2 nm to 1200 nm, 0 nm

Sweep Speed

≤0.2 s (span: 5 nm, Resolution: 0.1 nm), ≤0.3 s (span: 500 nm) \[VBW: 10 kHz, Normal dynamic range, sweep start to stop, no optical input, sampling point: ≤501\]

Display

800 × 600 dots, 8.4 inch SVGA color LCD

Measurement Functions

Auto Measure, Optical pulse measurement (External trigger), Power monitor

Display Functions

Normalized, Max Hold, Min Hold, Overlap, Value in Air/Vacuum, Effective Resolution, Multi fiber mode

Analysis Functions

Wavelength Subtraction, Marker, Wavelength Analysis (Threshold, ndB-Loss, Envelope, RMS, SMSR, Spectrum Power), Light Source Evaluation (FP-LD, DFB-LD, LED, LD Module), Optical AMP NF Evaluation, PMD Measurement, WDM Signal Evaluation, WDM Filter Analysis

Calibration Functions

Auto Align, Wavelength cal., Level offset, Wavelength offset

Memory Function

Display measurement data to memory A to J (10 waveforms)

Interfaces

Ethernet, GPIB (Option)

Input/Output

I/O: Save and read files to USB memory; Input: External trigger terminal (0 to 0.8 V / 2 V to 5 V, high impedance); Output: Measured data text file output, measurement screen file (BMP, PNG) output, VGA output

Operating Temperature

+5° to +45°C

Storage Temperature

\-20° to +60°C

Relative Humidity

0 to 90% (no condensation)

Power Supply

100 V(ac) to 120 V(ac) / 200 V(ac) to 240 V(ac), 50 Hz to 60 Hz, ≤75 VA

Dimensions

426 (W) × 177 (H) × 350 (D) mm (excluding projections)

Mass

≤15.0 kg (without options)

CE - EMC

2014/30/EU, EN61326-1, EN61000-3-2

CE - LVD

2014/35/EU, EN61010-1

CE - RoHS

2011/65/EU, EN50581

Remote Control Interfaces

Ethernet, GPIB (Opt-001)

**Important:** Wavelength accuracy of ±20 pm across 1520 nm to 1620 nm requires calibration using the MS9740A-002 Light Source for Wavelength Calibration option. Without this option, accuracy is specified at ±200 pm across 1520 nm to 1570 nm and ±300 pm across 1570 nm to 1750 nm (after Wl Cal Ext using an external light source).**Important:** When ordering the mainframe, one optical connector option (MS9740A-037 FC, MS9740A-038 ST, MS9740A-039 DIN 47256, or MS9740A-040 SC) must be specified.**Important:** The MS9740A-009 Multimode Fiber Interface is a factory option only; retrofit is not supported. When MS9740A-009 is specified, specifications are based on the MS9740A-009 (some features differ from the standard MS9740A).**Important:** Executing wavelength calibration with the MS9740A-002 Light Source for Wavelength Calibration option secures ±20 pm (1520 nm to 1620 nm, without MS9740A-009) accuracy. The MS9740A supports wavelength calibration with an external light source such as a DFB-LD, but this option assures higher accuracy.**Important:** When controlling the MS9740A remotely using the Ethernet port, a VISA driver must be installed in the PC controller. The licensed NI-VISA driver is provided free-of-charge for use when performing remote control of an MS9740A in which the MS9740A-001 GPIB option has been installed.**Important:** MS9740A-002 Light Source for Wavelength Calibration complies with optical safety standards in Class 1 of IEC 60825-1:2007.Usage tip: pair the MS9740A with the Anritsu MP2100B BERTWave for combined optical spectrum analysis and bit error rate testing of XFP and SFP+ transceiver outputs, as illustrated in the datasheet's optical transceiver measurement example.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Anritsu
- **Type:** Spec An
- **Tags:** Analyzers, Anritsu, Manufacturers, Optical, product_manual_group_2, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Anritsu MS9740A Optical Spectrum Analyzer, 600 nm to 1750 nm (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/ms9740a-anritsu-optical-analyzer-used)
> Updated: 2026-05-30