# Anritsu MS4644B 40 GHz Microwave Vector Network Analyzer (Pre-Owned)

# Anritsu MS4644B 40 GHz Microwave Vector Network Analyzer (Pre-Owned)

## Key Features At A Glance

-   Microwave Vector Network Analyzer family covering 70 kHz to 20 GHz (MS4642B), 10 MHz to 40 GHz (MS4644B), and 10 MHz to 70 GHz (MS4647B), with optional 70 kHz low-end extension available for the higher-frequency models
-   Single-sweep frequency coverage from 70 kHz to 70 GHz on the MS4647B eliminates the band-switch discontinuities that limit measurement quality on banded systems
-   1 Hz frequency resolution with ±5 × 10⁻⁷ Hz/Hz accuracy at time of calibration and <1 × 10⁻⁹/day aging stability
-   IF bandwidth selectable from 1 Hz to 1 MHz across discrete steps, supporting both fast production sweeps and low-noise-floor characterization
-   Up to 25,000 data points across 16 channels, or 100,000 data points in single-channel mode for high-resolution sweeps
-   26.4 cm (10.4-inch) color touchscreen with up to 16 traces per channel and a wide range of rectilinear and polar graph types including Smith Chart
-   Remote control via GPIB (IEEE 488.2), LAN (VXI-11), and USB (USBTMC), with SCPI command support plus emulation compatibility for legacy Lightning VNA and HP/Agilent 8510x commands
-   Optional capabilities standard across the family include Time Domain, Receiver Offset, Universal Fixture Extraction, Noise Figure, PulseView, DifferentialView, IMDView, Eye Diagram, and Multi-Line LRL calibration support (each ordered separately per the datasheet options list)

The Anritsu MS4640B Series VectorStar is a family of high-performance microwave vector network analyzers offered in three base configurations: the MS4642B covering 70 kHz to 20 GHz, the MS4644B covering 10 MHz to 40 GHz, and the MS4647B covering 10 MHz to 70 GHz. The MS4644B and MS4647B can be extended to a 70 kHz low-end start frequency through Option 70. The MS4640B Series is designed for broadband network analysis applications where wide frequency coverage, low noise floor, and flexible calibration methodologies are required in a single instrument platform.

These VNAs are used for the characterization of RF and microwave components, subsystems, and active devices. Application areas explicitly addressed in the datasheet include S-parameter measurement of passive and active devices, noise figure measurement (with Option 41 or differential noise figure with Option 48), intermodulation distortion analysis (with IMDView Option 44), mixer and frequency-translated device characterization (with Receiver Offset Option 7 and Dual Source Option 31), pulsed RF measurements (with PulseView Option 42 and IF Digitizer Option 35), differential device characterization (with DifferentialView Option 43), eye diagram generation from measured trace data (Option 47), and time-domain reflectometry-style analysis (Option 2). The optional MN4765B O/E Calibration Module extends the platform to electro-optical and opto-electronic device measurements at common telecom wavelengths.

## Brand Heritage

Anritsu is a Japanese precision measurement company with roots extending to 1895. The VectorStar microwave VNA line traces in part to Anritsu's 1993 acquisition of Wiltron Company, which brought significant RF and microwave network analysis technology and a North American commercial presence into the Anritsu portfolio. Instruments and accessories carrying historical Wiltron model numbers are part of the same engineering lineage as today's Anritsu VNA products.

## Compare Other Models in This Series

The VectorStar MS4640B Series is a three-model family of microwave vector network analyzers that share a common platform, calibration system, optional capability set, and accessory ecosystem, but differ in maximum operating frequency. The shared platform means that a measurement procedure, calibration kit relationship, or automation script developed on one model in the family generally transfers directly to the others within their respective frequency limits.

The base models — MS4642B, MS4644B, and MS4647B — are distinguished primarily by the upper frequency limit they support and, for the two higher-frequency models, by whether the optional 70 kHz low-end frequency extension (Option 70) has been installed. Most of the platform's optional capabilities, including Time Domain, Receiver Offset, Dual Source Architecture, Noise Figure, PulseView, IMDView, and the Active Measurements Suite, are available across all three models per the datasheet's compatibility tables.

Each pre-owned MS4640B Series VNA listed below is its own product page with condition-matched pricing and configuration detail. Because installed options materially affect what an MS4640B VNA can measure, every listing should be reviewed for the specific option set present on that unit before finalizing a purchase.

The MS4642B covers 70 kHz to 20 GHz at the base configuration and is the entry point to the family for applications that do not require coverage above 20 GHz. The MS4644B extends the upper frequency limit to 40 GHz with a base coverage of 10 MHz to 40 GHz, and the MS4647B further extends to 70 GHz with a base coverage of 10 MHz to 70 GHz. The MS4644B and MS4647B can both be ordered with Option 70 to bring the low-end start frequency down to 70 kHz (extendable to 40 kHz per the datasheet), matching the standard low-end of the MS4642B.

System dynamic range and noise floor specifications scale somewhat with the model's frequency reach, particularly above 38 GHz on the MS4647B where additional band coverage introduces band-specific specifications. The comparison table that follows lists each available unit with its installed configuration, condition grade, and option set as documented at the time of grading.

Model

Frequency Range

Test Port Connector

Default Output Power

**MS4644B**

10 MHz to 40 GHz (70 kHz with Option 70)

K (male)

+5 dBm (Standard or Option 51/61/62)

MS4642B

70 kHz to 20 GHz

K (male)

+5 dBm (with Option 51, 61, or 62)

MS4647B

10 MHz to 70 GHz (70 kHz with Option 70)

V (male)

\-3 dBm Standard / -10 dBm with Option 51, 61, or 62

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   User Documentation USB
-   Optical USB Mouse
-   Power Cord

## Product Core & Specifications

Specification

Value

Channels, Display, and Traces

Channels and Traces

16 channels, each with up to 16 traces

Display

Color touch screen LCD, 26.4 cm (10.4 in) diagonal

Measurement Data Points

2 to 25,000 points in up to 16 channels; 2 to 100,000 points in single channel

Markers

12 markers per trace (x 16 traces x 16 channels, total 3,072)

IF Bandwidth

IF Bandwidth Range

1, 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 200, 300, 500, 700 Hz; 1, 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 200, 300, 500, 700 kHz; 1 MHz

Frequency Resolution, Accuracy, and Stability

Resolution

1 Hz

Accuracy

± 5 x 10⁻⁷ Hz/Hz (at time of calibration)

Stability

< 5 x 10⁻⁹/°C over 0 °C to 50 °C; < 1 x 10⁻⁹/day aging

Power Accuracy, Linearity, and Resolution

Accuracy (70 kHz to 0.01 GHz)

± 1.5 dB

Accuracy (0.01 to 40 GHz)

± 1.5 dB

Accuracy (40 to 67 GHz)

± 3.0 dB

Accuracy (67 to 70 GHz)

± 4.0 dB (± 3.0 typical)

Power Resolution

0.01 dB

Remote Operability

GPIB

IEEE 488.2, 1 MB/s data transfer

LAN

VXI-11 protocol, 2.5 MB/s data transfer

USB

USBTMC protocol, 5.5 MB/s data transfer

CPU, OS, Memory, and Security

CPU

Intel Core i5

Operating System

Microsoft Windows 7

Storage

Serial-ATA (SATA) Solid State Drive (SSD), > 30 GB

Front Panel Connections

Test Ports (MS4642B, MS4644B)

K (male), Universal Test Port Connectors

Test Ports (MS4647B)

V (male), Universal Test Port Connectors

Damage Input Levels

+27 dBm maximum, 40 VDC maximum

USB Ports

Four type A USB 2.0 (two front, two rear)

Rear Panel Connections

AC Power Input

350 VA maximum, 90 to 264 VAC, 47 to 63 Hz (power factor controlled)

LAN Port

10/100BaseT Ethernet

GPIB Ports

Type D-24, female, IEEE 488.2 compatible (Talker/Listener and Dedicated Controller)

10 MHz Reference In/Out

BNC (female); In: -10 dBm to +3 dBm; Out: 0 ± 5 dBm sinusoidal, 50 Ω

Mechanical

Height

267 mm body (6U); 286 mm between feet outer edges

Width

426 mm body; 487 mm between front panel handle outer edges

Depth

502 mm body; 591 mm between handle and foot outer edges

Weight

< 30 kg (< 66 lb), typical for fully-loaded MS4647B

Environmental – Operating

Specification

Conforms to MIL-PRF-28800F (class 3)

Temperature Range

0 °C to +50 °C

Relative Humidity

5 % to 90 % at +30 °C, Non-condensing

Altitude

4,600 m (15,000 ft)

Environmental – Non-Operating

Temperature Range

\-40 °C to +71 °C

Relative Humidity

0 % to 95 % at +30 °C, Non-condensing

Altitude

4,600 m (15,000 ft)

Regulatory Compliance

European Union

EMC 2014/30/EU, EN 61326:2013; Low Voltage Directive 2014/35/EU; Safety EN 61010-1:2010; RoHS 2011/65/EU

Australia/New Zealand

RCM AS/NZS 4417:2012

South Korea

KCC-REM-A21-0004

Warranty

Instrument and Built-In Options

3 years from date of shipment (standard warranty)

Calibration Kits

Typically 1 year from date of shipment

Test Port Cables

Typically 1 year from date of shipment

Calibration

Recommended Calibration Cycle

12 months

**Important:** Maximum damage input level at test ports 1 and 2 is +27 dBm and 40 VDC. Direct access loop ports are rated to +20 dBm maximum and 0 VDC maximum, except source loop ports which are rated to +27 dBm maximum.**Important:** Recommended Calibration Cycle: 12 months. Residual specifications also require calibration kit calibration cycle adherence.**Important:** Warm-Up Time: After 90 minutes of warm-up time, where the instrument is left in the ON state.**Important:** Specifications do not include effects of any user cables, adapters, or fixtures attached to the instrument.**Important:** Damage Input Levels on Test Ports 1 and 2: +27 dBm maximum, 40 VDC maximum.**Important:** A calibration kit and test port cables must be ordered separately to perform measurements; the appropriate Mechanical Calibration Kit, AutoCal Module, or Verification Kit (3650A/3652A/3654D/3657/36585-series/3666-1/3668-1/3669B-1) is selected based on test port connector type (K or V) and required calibration method.**Important:** MS4642B minimum configuration requires one of Options 8 or 9.**Important:** Option 32 Internal RF Combiner requires Option 7 Receiver Offset and Option 31 Dual Source Architecture.**Important:** Option 41 Noise Figure requires Option 51 or Option 61 or Option 62.**Important:** Option 42 PulseView requires Option 35 IF Digitizer.Recommended pairing: the 36585 Series Precision AutoCal modules (36585K for K-connector systems to 40 GHz, 36585V for V-connector systems to 70 GHz) are the matched automatic calibration solution for this VNA family per the datasheet, available in male-male, female-female, and male-female configurations.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Anritsu
- **Type:** Network Analyzer
- **Tags:** Analyzers, Anritsu, Manufacturers, Network, product_manual_group_2, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Anritsu MS4644B 40 GHz Microwave Vector Network Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/ms4644b-anritsu-network-analyzer-used)
> Updated: 2026-05-30