# Keysight U2331A 64-Channel 3 MSa/s USB Modular Multifunction DAQ (Pre-Owned)

# Keysight U2331A 64-Channel 3 MSa/s USB Modular Multifunction DAQ (Pre-Owned)

## Key Features At A Glance

-   LAN-free USB 2.0 connectivity with USBTMC-USB488 standard for plug-and-play PC-based data acquisition
-   Family spans 250 kSa/s to 3 MSa/s single-channel sampling with 12-bit or 16-bit ADC resolution
-   16-channel or 64-channel configurations (single-ended) with software-selectable differential mode
-   Programmable bipolar input ranges down to ±1.25 V (±0.05 V on U2331A) for low-level signal capture
-   24-bit programmable digital I/O and two independent up/down counters standard across the family
-   Two analog output channels (on U2351A/U2353A/U2355A/U2356A/U2331A) with predefined sine, square, triangle, sawtooth, and noise waveform generation
-   Functions standalone or expands to 384 channels when installed in the U2781A USB modular product chassis
-   Self-calibration with on-board 5 V reference (±2 ppm/°C temperature drift)

The Keysight U2300A Series is a family of USB-connected modular multifunction data acquisition (DAQ) devices delivering PC-based measurement across two product groups. The basic multifunction family includes the U2351A, U2352A, U2353A, and U2354A with 16 single-ended (8 differential) channels at 250 kSa/s or 500 kSa/s. The high-density multifunction family includes the U2355A, U2356A, and U2331A with 64 single-ended (32 differential) channels, scaling up to 3 MSa/s single-channel sampling on the U2331A. Each device combines analog input, digital I/O, counter/timer, and on select models analog output and waveform generation in a single compact USB module.

The U2300A Series is positioned for research and development, manufacturing test, and design validation environments where multi-parameter electrical measurements must be acquired, logged, and analyzed on a host PC. Specific use cases called out for the family include applications spanning industrial and education settings where fast sampling, channel density, and flexible trigger configuration are required. The optional U2802A 31-channel thermocouple input signal conditioner extends the U2355A and U2356A into temperature measurement for product thermal analysis and characterization, environmental chamber profiling, process monitoring in consumer electronics, material properties testing, study of electronic temperature properties, and appliance testing using J, K, R, S, T, N, E, and B thermocouple types per the NIST ITS-90 database.

## Brand Heritage

Keysight Technologies was spun off from Agilent Technologies in 2014, and Agilent had earlier been separated from Hewlett-Packard in 1999 as the test and measurement business. Instruments in the U2300A Series carry the engineering and calibration lineage of the HP and Agilent T&M heritage and are supported through Keysight's current service network.

## Compare Other Models in This Series

The U2300A Series is divided by the datasheet into two product groups. The basic multifunction USB DAQ family — U2351A, U2352A, U2353A, U2354A — provides 16 single-ended (8 differential) channels with 16-bit resolution and sample rates of either 250 kSa/s (U2351A, U2352A) or 500 kSa/s (U2353A, U2354A). The high-density multifunction USB DAQ family — U2355A, U2356A, U2331A — provides 64 single-ended (32 differential) channels, with the U2355A at 16-bit/250 kSa/s, the U2356A at 16-bit/500 kSa/s, and the U2331A at 12-bit/3 MSa/s (single channel) or 1 MSa/s (multiple channels).

All seven models share a common architectural foundation: 24-bit programmable digital I/O, two general-purpose up/down counters, internal and external trigger options including SSI/Star trigger for chassis-based multi-module synchronization, Hi-Speed USB 2.0 with USBTMC-USB488, SCPI/IVI-COM programming, and self-calibration against a 5 V on-board reference. The model differences come down to channel density, ADC resolution and sample rate, and whether analog output is included.

Each pre-owned model below is its own dedicated product page with its own pricing, availability, and accessories list. Confirm the configuration that matches your channel count, sample rate, resolution, and analog output requirement before ordering.

The most consequential differences across the family are channel count, sample rate, and ADC resolution. Channel count splits cleanly: 16 SE / 8 DI on the basic family, 64 SE / 32 DI on the high-density family. Sample rate steps through 250 kSa/s (U2351A, U2352A, U2355A), 500 kSa/s (U2353A, U2354A, U2356A), and 3 MSa/s single-channel / 1 MSa/s multi-channel (U2331A). ADC resolution is 16-bit on every model except the U2331A, which trades resolution for speed at 12-bit.

Analog output presence is the other axis. The U2351A, U2353A, U2355A, U2356A, and U2331A include two analog output channels with 1 MSa/s update rate and predefined sine/square/triangle/sawtooth/noise waveform generation. The U2352A and U2354A omit analog output entirely — choose these when the application is input-only and the AO channels would go unused. Output resolution is 16-bit on the U2351A, U2353A, U2355A, and U2356A, and 12-bit on the U2331A.

Model

Analog Input Channels

Max Sampling Rate

AI Resolution

**U2331A**

64 SE/32 DI

3 MSa/s (single ch); 1 MSa/s (multi-ch)

12 bits

U2351A

16 SE/8 DI

250 kSa/s

16 bits

U2352A

16 SE/8 DI

250 kSa/s

16 bits

U2353A

16 SE/8 DI

500 kSa/s

16 bits

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   AC/DC Power adapter
-   Power cord
-   USB extension cable
-   L-Mount kit (used with modular product chassis)
-   Keysight USB Modular Products Quick Start Guide
-   Certificate of Calibration

## Product Core & Specifications

Specification

Value

General Characteristics

Remote interface

Hi-Speed USB 2.0, USBTMC-USB488

Power requirement

+12 VDC (typical), 2 A (max) input rated current

Power consumption

+12 VDC, 550 mA maximum

Operating temperature

0 °C to +55 °C

Relative humidity

15% to 85% RH (non-condensing)

Altitude

Up to 2000 meters

Pollution Degree

2 (indoor use only)

Storage temperature

−20 °C to 70 °C

Safety compliance

IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition); USA: UL61010-1: 2004; Canada: CSA C22.2 No.61010-1:2004

EMC compliance

IEC/EN 61326-1 1998; CISPR 11: 1990/EN55011:1991, Class A, Group 1; Canada: ICES-001: 1998; Australia/New Zealand: AS/NZS 2064.1

Shock and vibration

Tested to IEC/EN 60068-2

I/O connector

68-pin female VHDCI Type

Module dimensions (W × D × H)

120.00 mm × 182.40 mm × 44.00 mm (with plastic casing); 105.00 mm × 174.54 mm × 25.00 mm (without plastic casing)

Terminal block dimensions

103.00 mm × 85.20 mm × 42.96 mm

Weight

565 g (with plastic casing); 400 g (without plastic casing)

Analog Input (Common)

Scan list memory

Up to 100 selectable channel entries

Input coupling

DC

Input impedance

1 GΩ / 100 pF

Operational common mode voltage range

±7.5 V maximum

Overvoltage protection

Power-on: Continuous ±30 V; Power-off: Continuous ±15 V

Trigger sources

External analog/digital trigger, SSI/Star trigger

Trigger modes

Pre-trigger, delay-trigger, post-trigger, and middle-trigger

FIFO buffer size

Up to 8 MSa

Digital I/O

Number of channels

24-bit programmable input/output

Compatibility

TTL

Input voltage

VIL = 0.7 V max, IIL = 10 μA max; VIH = 2.0 V min, IIH = 10 μA max

Input voltage range

−0.5 V to +5.5 V

Output voltage

VOL = 0.45 V max, IOL = 8 mA max; VOH = 2.4 V min, IOH = 400 μA max

General Purpose Digital Counter

Maximum count

(231−1) bits

Number of channels

Two independent up/down counter

Compatibility

TTL

Clock source

Internal or external

Base clock available

48 MHz

Maximum clock source frequency

12 MHz

Input frequency range

0.1 Hz to 6 MHz at 50% duty cycle

Pulse width measurement range

0.167 μs to 178.956 s

Analog Trigger

Trigger source

All analog input channels, External analog trigger (EXTA\_TRIG)

Trigger level

±Full scale for internal; ±10 V for external

Trigger conditions

Above high, below low, and window (software selectable)

Trigger level resolution

8 bits

Bandwidth

400 kHz

Input impedance for EXTA\_TRIG

20 kΩ

Coupling

DC

Overvoltage protection

Continuous for ±35 V maximum

Digital Trigger

Compatibility

TTL/CMOS

Response

Rising or falling edge

Pulse width

20 ns minimum

Calibration

On board reference voltage

5 V

Temperature drift

±2 ppm/°C

Stability

±6 ppm/1000 hrs

General

Device class

USBTMC-USB488

Programmable interface

Standard Commands for Programmable Instruments (SCPI) and IVI-COM

**Important:** The U2300A Series analog input common-mode operational range is ±7.5 V maximum. Inputs are protected to ±30 V power-on and ±15 V power-off continuous, and the external analog trigger input (EXTA\_TRIG) is protected to ±35 V continuous.**Important:** USBTMC-USB488 compatibility is for Microsoft Windows operating systems only. Requires a direct USB connection to the PC so the appropriate driver can be installed in the USB DAQ module.**Important:** 20 minutes warm-up time is recommended for calibration specifications.**Important:** When multiple channels are used, the sampling rate of each channel is the maximum sampling rate divided by the number of channels used. For multiple channels on the U2331A, the sampling rate of each channel = (1 MSa/s) / number of channels used.**Important:** Terminal block and SCSI-II 68-pin cable (U2901A or U2902A) are optional accessories and not included with the base unit; required for field wiring access to the 68-pin VHDCI I/O connector.**Important:** U2802A Thermocouple Input Signal Conditioner is designed for use with the U2355A/U2356A USB Modular Multifunction DAQ for temperature measurements with thermocouples (standalone operation only).Recommended pairing: install U2300A Series modules in the Keysight U2781A USB Modular Product Chassis to expand to as many as 384 channels with SSI/Star trigger synchronization and a shared 10 MHz reference clock. For temperature measurement on the U2355A or U2356A, add the U2802A 31-channel thermocouple input signal conditioner.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Keysight
- **Type:** Data Log
- **Tags:** Agilent, Agilent Keysight, Data Logger, Manufacturers, Meters & DAQ, product_manual_group_2, Product_used