# Tektronix DPO2014B 100 MHz 4-Channel Digital Phosphor Oscilloscope (Pre-Owned)

# Tektronix DPO2014B 100 MHz 4-Channel Digital Phosphor Oscilloscope (Pre-Owned)

## Key Features At A Glance

-   Bandwidth from 70 MHz to 200 MHz across the series, in 2- and 4-analog-channel models
-   1 GS/s sample rate and 1 Mpoint record length standard on all channels, every model
-   MSO models add 16 integrated digital channels for time-correlated mixed-signal analysis
-   5,000 wfm/s maximum waveform capture rate with digital phosphor intensity grading
-   Wave Inspector controls for rapid waveform navigation and automated record search
-   FilterVu variable low-pass filter removes noise while capturing glitches to full bandwidth
-   Standard USB 2.0 host and device ports; optional 10/100 Ethernet and Video Out via DPO2CONN
-   Optional serial triggering, decode, and search for I2C, SPI, CAN, LIN, and RS-232/422/485/UART (application modules)

The Tektronix MSO2000B and DPO2000B Series is a family of mixed signal oscilloscopes that delivers advanced debug features at an entry-level price. The series offers up to 200 MHz of bandwidth and a 1 GS/s sample rate, with up to 20 channels available for analyzing analog and digital signals together. A deep record length of 1 Mpoint comes standard on all channels, letting you capture long windows of signal activity while maintaining fine timing resolution.

An oscilloscope captures voltage waveforms over time and displays them on screen, giving an engineer a direct view of a signal's amplitude, frequency, timing, and shape. This series is built to speed every stage of debugging a complex design — discovering an anomaly, capturing it, searching the waveform record for the event, and analyzing the device's behavior. Its tools target the infrequent problems common in digital systems, including runt pulses, glitches, and timing issues, and support troubleshooting of system-level interactions in complex embedded systems.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where we have specialized in new and used test and measurement equipment since 1992. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

## Brand Heritage

Tektronix was founded in 1946 in Oregon and built its reputation on oscilloscope technology. In 2007 it became a subsidiary of Danaher Corporation, and in 2016 it moved under Fortive Corporation following Fortive's spinoff from Danaher. The Tektronix brand itself has remained constant throughout.

## Compare Other Models in This Series

The MSO2000B and DPO2000B Series groups twelve models on a common platform: a 1 GS/s sample rate on all channels, a 1 Mpoint record length on every channel, a 5,000 wfm/s maximum waveform capture rate, and Wave Inspector navigation and search. The DPO models are digital phosphor oscilloscopes, while the MSO models add 16 integrated digital channels for mixed-signal analysis.

Within that shared platform, the models step through three bandwidth tiers and two analog-channel counts, so a buyer can match bandwidth and channel requirements without changing instrument family or learning a different user interface.

Each pre-owned model below is its own dedicated product page with condition-matched pricing. Use the comparison table to identify the bandwidth, channel count, and MSO or DPO configuration you need, then open that model's page to see its current pre-owned availability.

The family separates along three axes. Bandwidth runs 70 MHz, 100 MHz, or 200 MHz, with corresponding rise-time specifications of 5 ns, 3.5 ns, and 2.1 ns. Analog channel count is either 2 or 4, with the model number's final digit indicating the channel count (a model ending in 2 is two-channel; ending in 4 is four-channel).

The MSO prefix designates models that add 16 digital channels to the corresponding DPO model; the DPO prefix designates the digital phosphor oscilloscope without those digital channels. Sample rate (1 GS/s), record length (1 Mpoint), and maximum waveform capture rate (5,000 wfm/s) are identical across every model. See the comparison table for the exact bandwidth, rise time, and channel configuration of each model.

Model

Bandwidth

Analog Channels

Digital Channels

**DPO2014B**

100 MHz

4

0

DPO2002B

70 MHz

2

0

DPO2004B

70 MHz

4

0

DPO2012B

100 MHz

2

0

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   TPP0200 200 MHz, 10x passive probe (one per analog channel)
-   063-4472-xx Documentation CD
-   071-3078-xx Installation and safety manual
-   Power cord
-   OpenChoice Desktop software
-   Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration

## Product Core & Specifications

Specification

Value

Model Overview

Analog channels

2 (MSO/DPO2002B, 2012B, 2022B); 4 (MSO/DPO2004B, 2014B, 2024B)

Bandwidth

70 MHz (MSO/DPO2002B, 2004B); 100 MHz (MSO/DPO2012B, 2014B); 200 MHz (MSO/DPO2022B, 2024B)

Rise time

5 ns (70 MHz models); 3.5 ns (100 MHz models); 2.1 ns (200 MHz models)

Sample rate

1 GS/s on all channels (all models)

Record length

1 M points on all channels (all models)

Digital channels

MSO models add 16 digital channels to the corresponding DPO model

Vertical System, Analog Channels

Hardware bandwidth limits

20 MHz

Input coupling

AC, DC, GND

Input impedance

1 MΩ ±2%, 11.5 pF ±2 pF

Input sensitivity range

2 mV/div to 5 V/div

Vertical resolution

8 bits

Maximum input voltage, 1 MΩ

300 VRMS with peaks ≤ ±450 V

DC gain accuracy (with offset set to 0 V)

±3% for 10 mV/div to 5 V/div; ±4% for 2 mV/div to 5 mV/div

Channel-to-channel isolation (any two channels at equal vertical scale)

≥100:1 at ≤70 MHz (2002B/2004B); ≥100:1 at ≤100 MHz (2012B/2014B); 100:1 at ≤200 MHz (2022B/2024B)

Offset range, 1 MΩ input (2 mV/div to 200 mV/div)

±1 V

Offset range, 1 MΩ input (>200 mV/div to 5 V/div)

±25 V

Bandwidth at 2 mV/div

20 MHz, all models

Vertical System, Digital Channels (MSO models)

Input channels

16 digital (D15 to D0)

Thresholds

Threshold per set of 8 channels

Threshold selections

TTL, CMOS, ECL, PECL, User-defined

User-defined threshold range

±20 V

Threshold accuracy

±\[100 mV + 3% of threshold setting\]

Maximum input voltage

±40 V

Input dynamic range

80 Vpk-pk (threshold setting dependent)

Minimum voltage swing

500 mVp-p

Input resistance

101 kΩ

Probe loading

8 pF

Vertical resolution

1 bit

Horizontal System, Analog Channels

Maximum duration of time captured at highest sample rate (all channels)

1 ms

Time base range

200 MHz models: 2 ns to 100 s; 70, 100 MHz models: 4 ns to 100 s

Time-base delay time range

\-10 divisions to 5000 s

Channel-to-channel deskew range

±100 ns

Time base accuracy

±25 ppm over any ≥1 ms interval

Horizontal System, Digital Channels (MSO models)

Maximum sample rate (main), channels D7-D0

1 GS/s (1 ns resolution)

Maximum sample rate (main), channels D8-D15

500 MS/s (2 ns resolution)

Maximum record length (main, all channels)

1 M points

Minimum detectible pulse width

5 ns

Channel-to-channel skew

2 ns typical

Trigger System

Trigger modes

Auto, Normal, and Single

Trigger coupling

DC, HF reject (attenuates >85 kHz), LF reject (attenuates <65 kHz), noise reject (reduces sensitivity)

Trigger holdoff range

20 ns to 8 s

Trigger sensitivity, typical — Internal DC coupled

0.4 div from DC to 50 MHz; 0.6 div >50 MHz to 100 MHz; 0.8 div >100 MHz to 200 MHz

Trigger sensitivity, typical — External (aux input)

200 mV from DC to 100 MHz, 1X attenuation

Trigger level range — Any input channel

±4.92 divisions from center of screen

Trigger level range — Aux Input (external trigger)

±6.25 V, 1X attenuation; ±12.5 V, 10X attenuation

Trigger types

Edge, Pulse Width, Runt, Logic, Setup and Hold, Rise/Fall Time, Video (NTSC, PAL, SECAM); optional serial: I2C (up to 3.4 Mb/s), SPI (up to 10.0 Mb/s), RS-232/422/485/UART (up to 10 Mb/s), CAN (up to 1 Mb/s), LIN; Parallel (MSO models only)

Acquisition System

Sample

Acquire sampled values

Peak Detect

Captures glitches as narrow as 3.5 ns at all sweep speeds

Averaging

From 2 to 512 waveforms included in average

Roll

Scrolls waveforms right to left at sweep speeds slower than or equal to 40 ms/div

Waveform Measurements

Cursors

Waveform and Screen

Automatic measurements

29, of which up to four can be displayed on-screen at any one time

Gating

Isolate the specific occurrence within an acquisition using screen or waveform cursors

Waveform Math

Arithmetic

Add, subtract, and multiply waveforms

FFT

Spectral magnitude. FFT Vertical Scale: Linear RMS or dBV RMS; FFT Window: Rectangular, Hamming, Hanning, or Blackman-Harris

Display System

Display type

7 inch (180 mm) wide format liquid crystal TFT color display

Display resolution

480 horizontal × 234 vertical pixels (WQVGA)

Waveform styles

Vectors, Dots, Variable Persistence, Infinite Persistence

> **Important:** The optional 10/100 Ethernet (LAN) port and Video Out port require the DPO2CONN module.

> **Important:** Serial protocol triggering and analysis (I2C, SPI, CAN, LIN, and RS-232/422/485/UART) is optional and requires the appropriate application module (DPO2AUTO, DPO2COMP, DPO2EMBD, or the DPO2BND bundle). It is offered free for a 30-day trial that starts automatically when the instrument is first powered on.

> **Important:** Bandwidth is 20 MHz at 2 mV/div on all models.

> **Important:** To use TekVPI active, differential, or current probes on the MSO/DPO2000B, the oscilloscope requires a TekVPI external power supply (119-7465-xx / 119-8726-xx), one per oscilloscope, plus an appropriate power cord for the country of use.

> **Important:** On the DPO2EMBD module, only two-wire SPI support is available on two-channel models.

> **Important:** Parallel bus triggering is available on MSO models only.

> **Important:** The five-year warranty covers all parts and labor, excluding probes.

> Recommended pairing: the TekVPI active, differential, and current probes in the recommended accessories list — such as the TAP1500, TDP0500, and TCP0030A — extend the series to high-voltage, differential, and current measurements.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Backed by a ValueTronics warranty.
-   Functional verification included.
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Tektronix
- **Type:** Dig Oscilloscope
- **Tags:** Digital, DPO2014, DPO2014B, Inc., Manufacturers, Model 2014, Ms Oscilloscope, Oscilloscopes, Pre-Owned, product_manual_group_2, Product_used, Tektronix, Updated Item Review

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- DPO2014B Tektronix Digital Oscilloscope

---

> Source: [ValueTronics](https://valuetronics.com/products/dpo2014b-tektronix-digital-oscilloscope-used)
> Updated: 2026-06-03