# Keithley 2001 - 7.5 Digit Multimeter - Used

### Key Features at a Glance

-   True 7.5-digit resolution based on a 28-bit A/D converter
-   1 nV resolution; 1 nV to 1100 V on DC voltage
-   Exceptional measurement integrity at high speed
-   Built-in peak detector captures spikes down to 1 µs
-   TRMS AC, average AC, peak AC, AC+DC, and crest factor measurement
-   1 Hz to 15 MHz frequency counter; up to 2000 readings/s at 4.5 digits
-   DC in-circuit current measurement
-   Optional 10-channel scanner card for built-in multiplexing

In summary, the Keithley 2001 is a 7.5-digit high-performance digital multimeter built around a 28-bit A/D converter. It delivers performance specifications usually associated with instruments costing several thousand dollars more, and offers a broad range of built-in measurements: TRMS AC, DC in-circuit current, peak spikes, temperature with thermocouples or RTDs, and frequency to 15 MHz.

## What is the Keithley 2001 used for?

The 2001 is used wherever exceptional resolution and accuracy are required alongside the throughput needed for production test or scan-and-measure applications. With the optional plug-in scanner card it becomes a complete 10-channel measurement system for production test, design verification, and metrology where high accuracy is critical.

### How does true 7.5-digit resolution work?

Many DMMs claim 7.5-digit resolution but reach it only by averaging multiple readings. The 2001's resolution comes from its 28-bit A/D converter directly, providing the dynamic range to measure from 1 µV to 20 V on a single range without range-shift errors or delays.

### Factual grounding — DC voltage performance

Specification

Value

200 mV range, 1-year accuracy

±(37 ppm rdg + 6 ppm rng)

2 V range, 1-year accuracy

±(25 ppm rdg + 2 ppm rng)

20 V range, 1-year accuracy

±(24 ppm rdg + 4 ppm rng)

200 V range, 1-year accuracy

±(38 ppm rdg + 3 ppm rng)

1000 V range, 1-year accuracy

±(41 ppm rdg + 6 ppm rng)

Input resistance (200 mV to 20 V)

\>10 GΩ

### Entity authority

The Keithley 2001 is a metrology-grade DMM that sits alongside HP/Agilent 3458A-class instruments at a significantly lower acquisition cost. Patented AC measurement circuitry delivers AC accuracy that is several times better than typical DMMs at low signal levels — guaranteed down to 1% of selected range versus 5 to 10% for most other instruments.

### Applications

-   Production test, design verification, and metrology
-   Standard cell comparisons and transfer measurements (DCV transfer)
-   Low-frequency AC measurement — vibration, servo, guidance, control systems
-   Peak-spike capture on power supplies, transients, and short dropouts
-   Temperature measurement with thermocouple or RTD inputs

## Accessories Supplied

Standard accessory packages ship where applicable. Unnecessary accessories may not be included on this Pre-Owned unit; contact a Test Architect to confirm anything specific your application requires.

## Product Core and Specifications

The 2001 wraps its 28-bit A/D in an extensive measurement function set: DCV, ACV, DCI, ACI, 2- and 4-wire resistance to 1 GΩ, frequency to 15 MHz with adjustable trigger level, temperature, peak-spike capture, and DC in-circuit current. A built-in bar-graph display indicates data as a percentage of range from ±0.01% to ±100%, replacing a separate nulling differential voltmeter for trend monitoring.

### AC voltage performance

Specification

Value

200 mV / 2 V range, 0.1 to 2 kHz

±(0.03% rdg + 0.015% rng)

20 V / 200 V range, 2 to 10 kHz

±(0.06% rdg + 0.015% rng)

Bandwidth (typical)

1 Hz to 2 MHz

Crest factor measurement range

20 Hz to 1 MHz

### Resistance, current, and frequency

Specification

Value

4-wire ohms range

20 Ω to 1 GΩ (2-wire)

20 Ω 4W range, 1-year accuracy

±(72 ppm rdg + 7 ppm rng)

DC current range

200 µA to 2 A

AC current bandwidth (typical)

20 Hz to 100 kHz

Frequency counter input

1 Hz to 15 MHz, ±0.03% rdg

Peak-spike detection

Single-event down to 2 µs; repetitive 500 ns

### General

Specification

Value

Power

90 to 134 V and 180 to 250 V universal self-selecting; 50/60/400 Hz self-identifying

Consumption

<55 VA

Operating temperature

0 to 50 °C

Humidity

80% RH to 35 °C

Dimensions

90 mm H × 214 mm W × 369 mm D

Weight

<4.2 kg (<9.2 lb)

EMC

Conforms to VDE 0871B, IEC 801-2; FCC Part 15 Class B

Safety

Conforms to IEC 348, CAN/CSA-C22.2 No. 231, MIL-T-28800E

### Scanner Card Option

The 2001 accepts an optional 10-channel scanner card (2000-SCAN), a 10-channel scanner card with two high-speed channels (2001-SCAN), or a 9-channel thermocouple scanner card (2001-TCSCAN). The scanner cards turn the 2001 into a self-contained scan-and-measure system without a separate external scanner.

### About This Pre-Owned Unit

-   Warranty included.
-   Functional verification included.
-   Calibration available as an optional add-on service.
-   Unnecessary accessories may not be included; contact a Test Architect to confirm anything specific.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

## Details

- **Price:** 0.0 USD
- **Vendor:** Keithley
- **Type:** Multi Met
- **Tags:** Keithley, Manufacturers, Meters & DAQ, Multimeter, product_manual_group_1, Product_used, Updated Item Review

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- Keithley 2001 - 7.5 Digit Multimeter - Used

---

> Source: [ValueTronics](https://valuetronics.com/products/2001-keithley-multimeter-used)