# Keithley DMM7512 Dual Channel 7½-Digit Sampling Multimeter

# Keithley DMM7512 Dual Channel 7½-Digit Sampling Multimeter

## Key Features At A Glance

-   Two independent 7½-digit DMMs in a 1U-high, full-rack-width chassis that minimizes rack space in high-density systems
-   Dual 1 Msample/s 18-bit digitizers capture waveforms or identify transients on voltage or current
-   Trigger a waveform measurement on a signal level, a rising or falling edge, a window, or a digital trigger
-   Store up to 27.5 million timestamped readings on a waveform
-   Basic one-year DC voltage accuracy as low as 14 ppm (24 ppm resistance, 60 ppm DC current)
-   10 nV, 0.1 µΩ, and 1 pA sensitivities for high-resolution low-level measurements
-   USBTMC-compliant USB, LAN LXI-compliant, and TSP-Link interfaces for automated test systems
-   Auto-calibration plus a two-year calibration interval reduce drift and life-cycle costs

The Keithley DMM7512 Dual Channel 7½-Digit Sampling Multimeter combines two full-function, high-accuracy, high-sampling-speed DMMs into a compact 1U-high, full-rack-wide chassis. Each DMM has identical functionality and operates entirely independently of the other, so the small form factor saves rack space in high-instrument-density test systems without compromising measurement performance. Each channel reaches a basic one-year accuracy as low as 14 ppm for DC volts, 24 ppm for resistance, and 60 ppm for DC current.

With dual-channel capability, fast signal sampling, high-speed data transfer rates reaching up to 100,000 measurements/s, and internal execution of program test scripts, the DMM7512 reduces space and test time in automated test systems. Its 10 nV, 0.1 µΩ, and 1 pA sensitivities support high-resolution low-level measurements such as portable device sleep currents. Using the two DMMs as synchronized digitizers, one for voltage and one for current, power can be accurately computed on time-varying waveforms, and the instrument can measure current in all operating states of a device including the sleep state and the current burst state when the device is transmitting.

## Brand Heritage

Keithley Instruments operates as a Tektronix company, and its instruments are issued under that combined identity.

## Accessories Supplied

-   012178100 Test Lead Kit, Quantity 4
-   CA-18-16A LAN Crossover Cable, 40 cm (16 in), quantity 2
-   174710700 Shielded Crossover Cable with RJ-45 Connector, 1.5 m (5 ft), quantity 1
-   CA-568-120A Green and Yellow Ground Cable, 3.0 m (120 in), quantity 1
-   4299-13 1U High Fixed Rack Mount Kit, quantity 1
-   0713411 Safety Precautions Document
-   071357600 DMM7512 7½-Digit Multimeter Instrument Information

## Product Core & Specifications

Specification

Value

DC Voltage Accuracy (1 Year, TCAL ±5 °C) ±(ppm of reading + ppm of range)

100 mV range (10 nV res, >10 GΩ or 10 MΩ ±1%)

18 + 30

1 V range (100 nV res, >10 GΩ or 10 MΩ ±1%)

15 + 5

10 V range (1 µV res, >10 GΩ or 10 MΩ ±1%)

14 + 1.2

100 V range (10 µV res, 10 MΩ ±1%)

40 + 15 (22 + 15 within 30 days of autocalibration)

1000 V range (100 µV res, 10 MΩ ±1%)

40 + 10 (23 + 10 within 30 days of autocalibration)

DC Voltage Characteristics

ADC Linearity

1.0 ppm of reading + 1.0 ppm of range

Input Impedance

100 mV to 10 V Ranges: Selectable >10 GΩ || <400 pF (auto) or 10 MΩ ±1%; 100 V to 1000 V Ranges: 10 MΩ ±1%

Input Bias Current

<50 pA at 23 °C (autozero off or input impedance 10 MΩ)

Common Mode Current

<2.1 µA peak-peak in 1 MHz bandwidth; <100 nA peak-peak in 1 kHz bandwidth

Common Mode Voltage

500 VPEAK LO terminal to chassis maximum

DC Voltage Autozero Off Error

For ±1 °C and ≤10 minutes, add ±(8 ppm of reading + 15 µV)

Normal Mode Rejection (line frequency ±0.1%)

Line Sync On: 110 dB at 5 PLC, 90 dB at 1 PLC, 45 dB at ≤0.2 PLC; Line Sync Off: 60 dB at 5 PLC, 60 dB at 1 PLC

Common Mode Rejection (100 Ω unbalanced in LO)

140 dB at 5 PLC (Line Sync On), 140 dB at 1 PLC (On), 120 dB at 0.2 PLC (On), 80 dB at ≤0.2 PLC (Off)

Resistance Accuracy (1 Year, TCAL ±5 °C) ±(ppm of reading + ppm of range)

1 Ω (0.1 µΩ res, 10 mA test current)

50 + 60

10 Ω (1 µΩ res, 10 mA)

50 + 6

100 Ω (10 µΩ res, 1 mA)

47 + 4

1 kΩ (100 µΩ res, 1 mA)

41 + 3

10 kΩ (1 mΩ res, 100 µA)

42 + 3

100 kΩ (10 mΩ res, 10 µA)

50 + 3

1 MΩ (100 mΩ res, 10 µA)

50 + 5

10 MΩ (1 Ω res, 0.69 µA || 10 MΩ)

400 + 10

100 MΩ (10 Ω res, 0.69 µA || 10 MΩ)

2000 + 30

1 GΩ (100 Ω res, 0.69 µA || 10 MΩ)

13000 + 200

Resistance Characteristics

Maximum 4-Wire Ohms Lead Resistance

5 Ω per lead for 1 Ω range, 10% of range per lead for 10 Ω to 1 kΩ ranges; 1 kΩ per lead for all other ranges

Offset Compensation

Selectable on 4-wire, 1 Ω to 100 kΩ ranges

Open Lead Detector

Default is off

Input Current Limit

For ±12 V to ±40 V: ±13 mA source or sink, typical; for greater than ±40 V: ±130 µA source or sink, typical

DC Current Accuracy (1 Year, TCAL ±5 °C) ±(ppm of reading + ppm of range)

10 µA (1 pA res, 15 mV burden)

125 + 40

100 µA (10 pA res, 15 mV)

100 + 15

1 mA (100 pA res, 15 mV)

100 + 15

10 mA (1 nA res, 20 mV)

100 + 15

100 mA (10 nA res, 200 mV)

400 + 30

1 A (100 nA res, 400 mV)

450 + 50

3 A (1 µA res, 1300 mV)

450 + 40

DC Current Characteristics

Effective Internal Shunt Value

10 µA: 1 kΩ; 100 µA: 100 Ω; 1 mA: 10 Ω; 10 mA: 1 Ω; 100 mA: 0.1 Ω; 1 A: 0.1 Ω; 3 A: 0.1 Ω

Autozero Off Error (±1 °C, ≤10 min, add ±(8 ppm of reading + range error))

10 µA: 150 pA; 100 µA: 1.5 nA; 1 mA: 15 nA; 10 mA: 150 nA; 100 mA: 15 µA; 1 A: 150 µA; 3 A: 150 µA

Temperature — 4-Wire / 3-Wire RTD (Accuracy 2 Year, TCAL ±5 °C)

RTD Types

100 Ω platinum PT100, D100, F100, PT385, PT3916; or user-configurable 0 Ω to 10 kΩ

4-Wire RTD (–200° to 400 °C, 0.01 °C res)

0.09 °C

3-Wire RTD (–200° to 400 °C, 0.01 °C res)

0.75 °C

Temperature — Thermistor (Accuracy 2 Year, TCAL ±5 °C)

Thermistor Types

2.252 kΩ, 5 kΩ, and 10 kΩ

Thermistor (–80° to +150 °C, 0.01 °C res)

0.08 °C

Temperature — Thermocouple (Accuracy 2 Year, TCAL ±5 °C, simulated reference junction)

B (350 to +1820 °C, 0.1 °C res)

0.9 °C

E (−200 to +1000 °C, 0.001 °C res)

0.4 °C

J (−200 to +760 °C, 0.001 °C res)

0.4 °C

K (−200 to +1372 °C, 0.001 °C res)

0.4 °C

N (−200 to +1300 °C, 0.001 °C res)

0.4 °C

R (0 to +1768 °C, 0.1 °C res)

0.9 °C

S (0 to +1768 °C, 0.1 °C res)

0.9 °C

T (−100 to +400 °C, 0.001 °C res)

0.4 °C

Continuity (2 Year, TCAL ±5 °C)

1.0000 kΩ range (100 mΩ res, 1 mA test current, 14.0 V open circuit)

100 + 100 ±(ppm of reading + ppm of range)

Continuity High Limit

User-selectable; default 10 Ω

Digitize Voltage Accuracy (1 Year, TCAL ±5 °C) ±(ppm of reading + ppm of range)

100 mV (1 µV res, >10 GΩ or 10 MΩ ±1%)

220 + 100

1 V (10 µV res)

120 + 75

10 V (0.1 mV res)

120 + 75

100 V (1 mV res, 10 MΩ ±1%)

120 + 75

1000 V (10 mV res, 10 MΩ ±1%)

120 + 75

Digitize Current DC Accuracy (1 Year, TCAL ±5 °C) ±(ppm of reading + ppm of range)

10 µA (0.1 nA res, 15 mV burden)

160 + 75

100 µA (1 nA res, 15 mV)

160 + 75

1 mA (10 nA res, 15 mV)

160 + 75

10 mA (100 nA res, 20 mV)

160 + 75

100 mA (1 µA res, 200 mV)

450 + 100

1 A (10 µA res, 400 mV)

500 + 110

3 A (100 µA res, 1300 mV)

900 + 150

Digitizer Characteristics

Maximum Resolution

18 bits

Measurement Input Coupling

DC or AC (voltage only)

Sampling Rate

Programmable 1 k through 1 million

Volatile Sample Memory with Timestamp

27.5 million

Minimum Record Time

1 µs

Timestamp Resolution

1 ns with standard or full buffer style; 1 µs with compact buffer style

Timestamp Accuracy

Standard or full buffer style: 20 ns between adjacent readings (total buffer time <2 s); compact buffer style: 2 µs adjacent readings

Maximum Record Length

8 million

Digitize Typical (Sampling Rate / Digits / Resolution / Measurements Into Computer)

10 kS/s

5½ digits, 18-bit resolution, 9700 readings/s

20 kS/s

4½ digits, 16-bit, 19000 readings/s

50 kS/s

4½ digits, 16-bit, 44400 readings/s

100 kS/s

4½ digits, 15-bit, 80000 readings/s

1 MS/s

3½ digits, 12-bit, 108000 readings/s

Buffer Transfer Speed, Binary (Measurements into Computer per second)

USB / LAN, average for 1000 readings

280000 (USB) / 270000 (LAN)

USB / LAN, average for 1000 readings with timestamp

170000 (USB) / 140000 (LAN)

Triggering

Time Base Accuracy

25 ppm

Trigger Source

Analog DCV, DCI, or any system trigger

Trigger Coupling

DC

> **Important:** Input protection: 1010 V DC on all ranges and functions for the HI and LO terminals; 350 V for the sense HI and sense LO terminals; 250 V rated for the current input terminal.

> **Important:** The DMM7512 does not have a front panel display; the instrument has a built-in web browser with a virtual front panel that is displayed on a PC monitor through a LAN interface connection.

> Usage tip: pair the DMM7512 with the Keithley 2606B System SourceMeter SMU Instrument over TSP-Link to stimulate and measure multiple DUTs as a single integrated, script-controlled test system.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 11000.0 USD
- **Vendor:** Keithley
- **Type:** Multi Met
- **Tags:** DMM7512, Factory New, Inc., Keithley, Keithley Instruments, Manufacturers, Meters & DAQ, Model 7512, Multimeter, product_manual_group_1, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 11000.00 USD | In stock |

## Images

- Keithley DMM7512 Dual Channel 7½-Digit Sampling Multimeter
- Keithley DMM7512 Dual Channel 7½-Digit Sampling Multimeter

---

> Source: [ValueTronics](https://valuetronics.com/products/dmm7512-keithley-multimeter-new)
> Updated: 2026-06-02