# SLH-60-240-1800 Sorensen DC Electronic Load Used

**Additional Features:**

-   60V / 240A / 1800W rack mounted, programmable DC load
-   Fully programmable, high power AC/DC or DC electronic loads
-   High current, 60V DC models for general purpose power supply testing
-   Flexible Control
-   Flexible Data Feedback
-   GPIB, RS-232, Analog
-   Dynamic mode with slew rate control
-   Remote: GPIB, RS-232, Analog (DC only)
-   DC Modes: CC, CR, CV, CP
-   AC Modes: CR, CC with crest factor control
-   Dynamic mode with slew rate control
-   Flexible Data Feedback

**Flexible Product Line**

-   Low power DC modules
-   Low power AC / DC modules
-   High power DC modules
-   Stand along modules

**Specifications:**

**Input Ratings**

-   Voltage: 60 V
-   Current: 240 A
-   Power: 1800 W
-   Minimum Voltage (Full Current): 0.5V @ 240A

**CC Mode**

-   Range: 0-24 / 0-240A
-   Resolution: 6.4 / 64mA
-   Accuracy: ±0.2% OF (SETTING + RANGE)

**CR Mode**

-   Range 1 (I>0.05% of rating): 0.25 - 937.50Ω
-   Range 2 (I>0.5% of rating): 0.0133 - 0.25Ω

**CV Mode**

-   Range: 0 60V
-   Resolution: 0.016V
-   Accuracy: ±0.1% OF (SETTING + RANGE)

**CP Mode**

-   Range: 0-1800W
-   Resolution: 0.48W
-   Accuracy: ±0.5% OF (SETTING + RANGE)

**Short Mode**

-   Maximum Resistance: 2.1mΩ
-   Current: 240A

**Dynamic Mode**

-   T High / T Low: 50μs to 9.999s
-   Slew Rate Low: 16mA - 1A/μs
-   Slew Rate High: 0.160A - 10A/μs
-   Accuracy: ± (10% OF SETTING +10μs)

**4 1/2 DVM**

-   Range: 0 - 20.00 / 60.00V
-   Resolution: 0.001 / 0.01V
-   Accuracy: ±0.05% OF (READING + RANGE)

**4 1/2 DAM**

-   Range: 0 - 24A / 0 - 240A
-   Resolution: 1mA / 10mA
-   Accuracy: ±0.5% OF (READING + RANGE)

**Current Monitor**

-   24A/V

**Load ON Volt**

-   Range: 0.1 - 25V
-   Resolution: 0.1V
-   Accuracy: 1% of SETTING +0.25V

**Load OFF Volt**

-   Range: 0 - 25V
-   Resolution: 0.1V
-   Accuracy: 1% of SETTING +0.25V

**General**

-   Software: LabVIEW Driver can be downloaded at no cost: www.elgar.com/products/SL/SL\_Downloads.htm
-   Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant (LVD and EMC Directives)
-   Environmental: Operating Temperature: 0° to 40°C; Storage Temperature: -10° to 65°C
-   Cooling: Front, Side, Top Air Inlets, Rear Exhaust, Units may be rackmounted without spacing.
-   SLH Memory: 150 Settings for DC, 5 Settings for AC
-   Readback: Voltage, Current, Power: 16-bit resolution, VA: Vrms x Arms
-   Analog Input: SLH: BNC connector. DC, Single Input (SLH or SLM), CC Mode: 0-10V = 0 – FS, Bandwidth: 20kHz, Sums Current with Programmed Value (Analog programming not available on AC/DC modules.)
-   Remote Programming: RS-232C, GPIB, analog - not available on AC/DC modules
-   Input Power Line: 115V / 230V ± 10%, switch selectable or 100V / 200V ± 10% switch selectable (optional)
-   Frequency: 50 / 60Hz
-   Power Consumption: 100W Maximum

The Sorensen SLH-60-240-1800 is a Fully programmable, high power DC electronic load. The SLH-60-240-1800 is a High current, 60V DC model for general purpose power supply testing.

The image is a representation of selection. See specifications for product details.

## Details

- **Price:** 0.0 USD
- **Vendor:** Sorensen
- **Type:** Dc Loads
- **Tags:** DC Electronic Load, Manufacturers, Power Supplies & Loads, product_manual_group_1, Product_used, Sorensen

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- SLH-60-240-1800 Sorensen DC Electronic Load Used

---

> Source: [ValueTronics](https://valuetronics.com/products/slh-60-240-1800-sorensen-dc-electronic-load-used)
> Updated: 2026-05-21