# 3605 Associated Research HiPot Used

**Additional Features:**

-   5KV AC Hipot Tester
-   Patented SmartGFI® safety circuit protects the operator from shock hazards
-   Patented VERI-CHEK® feature prompts users through steps to validate the instrument’s operation
-   Patented CAL-ALERT® feature alerts the operator that the tester is due for re-calibration
-   Built-in adjustable Continuity test for checking basic continuity
-   Graphic LCD provides intuitive menu system to simplify the entire testing process from set-up to results
-   PLC Remote Control allows operators to remotely control the Hipot tester
-   Remote Safety Interlock feature prevents the high-voltage from being activated without the interlock enabled
-   Memories with 3 Steps per memory for storing and recalling test parameters
-   Electronic Ramp and Dwell timers for more consistent and reliable testing
-   Interconnects with an Associated Research Ground Bond tester to form a complete test system
-   Digitally controlled arc detection circuit allows the operator to program sensitivity levels for detecting arcs
-   Minimum and maximum trip settings for safer and more accurate testing
-   Comes complete with an adapter box for products terminated in a line cord

**Input Specifications**

-   Voltage: 115/230 VAC ± 10%, user selectable
-   Frequency: 50/60 Hz ± 5%
-   Fuse: 3.15 A, fast acting 250 VAC

**Dielectric Withstand Test Mode**

**Output Rating** 

-   5000 V @ 20 mA AC; 6000 V @ 7.5 mA DC

**Voltage Setting** 

-   Range: 0 - 5.00 KV AC; 0 - 6.00 KV DC
-   Resolution: 0.01 KV
-   Accuracy: ± (2% of setting + 5 V)

**Maximum Limit**

-   AC Range: 0.00 - 20.00 mA
-   Resolution: 0.01 mA
-   DC Range: 0 - 7500 μA
-   Resolution: 1 μA
-   Accuracy: AC and DC ± (2% of setting + 2 counts)

**Minimum Limit** 

-   AC Range: 0.000 - 9.999 mA
-   Resolution: 0.001 mA
-   DC Range: 0.0 - 999.9 μA
-   Resolution: 0.1 μA
-   Accuracy: AC and DC ± (2% of setting + 2 counts)

**Arc Detection**

-   Range: 0 - 9, 0 disabled

**Ground Fault Interrupt** 

-   GFI Trip Current: 450 μA max (AC or DC)
-   HV Shut Down Speed: < 1ms

**Current Display Auto Range**

-   AC Range 1: 0.000 - 3.500 mA
-   Range 2: 3.00 - 20.00 mA
-   DC Range 1: 0.0 μA - 350.0 μA
-   Range 2: 0.300 mA - 3.500 mA
-   Range 2: 3.00 mA - 7.50 mA
-   Accuracy All Ranges ± (2% of reading + 2 counts)

**DC Output Ripple** 

-   ≤5% Ripple RMS at 6 KV DC @ 7.5 mA, Resistive Load

**Discharge Time**

-   <=200 ms

The maximum capacitive load vs output voltage:

-   0.20 μF < 1 KV 0.050 μF < 4 KV
-   0.10 μF < 2 KV 0.040 μF < 5 KV
-   0.06 μF < 3 KV 0.015 μF < 6 KV

**AC Voltage Waveform**

-   Sine Wave, Crest Factor = 1.3 - 1.5, <2% THD

**Output Frequency**

-   Range: 50 or 60 HZ, User Selectable

**Output Voltage Regulation**

-   ± (1% of output + 5 V) from no load to full load and over input voltage range.

**Dwell Timer** 

-   Range: AC 0, 0.3 - 999.9 sec (0 = Constant)
-   DC 0, 0.4 - 999.9 sec (0 = Constant)
-   Accuracy: ± (0.1% of reading + 0.05 sec)

**Ramp Timer** 

-   Range: Ramp-Up: 0.1 - 999.9 sec
-   Ramp-Down: AC 0.0 - 999.9 sec
-   DC 1.0 - 999.9 sec (0=OFF)
-   Accuracy: ± (0.1% of reading + 0.05 sec)

**Ground Continuity Current**

-   DC 0.1 A ± 0.01 A, fixed

**Ground Continuity Maximum Limit, Minimum Limit**

-   Range: 0.0 Ω - 1.50 Ω
-   Resolution: 0.01 Ω
-   Accuracy: ± (3% of setting + 0.02 Ω)

**Ground Continuity Auto Offset**

-   Range: 0.0 Ω - 0.50 Ω
-   Resolution: 0.01 Ω
-   Accuracy: ± (3% of setting + 0.02 Ω)

**Insulation Resistance Test Mode**

**Voltage Setting**

-   Range: 30 - 1000 VDC
-   Accuracy: ± (2% of setting + 5 V)

**Resistance Display**

-   Range: 1 - 9999 MΩ (4 Digit, Auto Ranging)
-   Resolution: 500 VDC - 1000 VDC

MΩ                MΩ

0.001      1.000 - 9.999

0.01        10.00 - 99.99

0.1          100.0 - 999.9

1              1000 - 9999

**Accuracy**

-   ± (2% of reading +2 counts) at test voltage; 500 - 1000 V and 1 - 999.9 MΩ
-   ± (5% of reading +2 counts) at test voltage; 500 - 1000 V and 1000 - 9999 MΩ
-   ± (8% of reading +2 counts) at test voltage; 30 - 500 V and 1 - 1000 MΩ

**Maximum Limit** 

-   Range: 0, 1 - 9999 MΩ (0=OFF)
-   Accuracy: Same as Resistance Display

**Minimum Limit** 

-   Range: 1 - 9999 MΩ
-   Accuracy: Same as Resistance Display

**Ramp Timer** 

-   Range: Ramp-Up: 0.1 - 999.9 sec
-   Ramp-Down: 1.0 - 999.9 sec (0=OFF)
-   Accuracy: ± (0.1% of reading + 0.05 sec)

**Delay Timer** 

-   Range: 0, 0.5 - 999.9 sec (0 = Constant)
-   Accuracy: ± (0.1% of reading + 0.05 sec)

**Ground Fault Interrupt**

-   GFI Trip Current: 450 μA max
-   HV Shut Down Speed: < 1 ms

**General Specifications**

Remote Control & Signal Output

The following input and output signals are provided through two 9 pin D type connectors:

1\. Remote control: Test, Reset, and Remote Interlock

2\. Remote recall of memory program #1, #2, and #3

3\. Outputs: Pass, Fail, Test-in-process, and Reset

-   Program Memory: 10 Memories, 3 steps per memory
-   Security: Key Lock capability to avoid unauthorized access to all test parameters and memory locations
-   Mechanical: Bench or rack mount with tilt up feet
-   Dimensions: (W x H x D) 8.46 x 3.5 x 14.57 in. (215 x 89 x 370 mm)
-   Calibration: Traceable to National Institute of Standards & Technology (NIST)
-   Calibration controlled by software
-   Adjustments are made through front panel keypad in a restricted access calibration mode
-   Calibration information stored in non-volatile memory

## Details

- **Price:** 0.0 USD
- **Vendor:** Associated Research
- **Type:** Hipot
- **Tags:** Associated Research, Hipot, Manufacturers, Other Equipment, product_manual_group_1, Product_used, Updated Item Review

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- 3605 Associated Research HiPot

---

> Source: [ValueTronics](https://valuetronics.com/products/3605-associated-research-hipot-used)
> Updated: 2026-05-21