# TLA7E2 Tektronix Logic Analyzer Used

**Additional Features:**

-   4 Channel Digitizing Oscilloscope Module with 15 Kb Memory Depth
-   Up to 1 GHz Bandwidth Provides High-fidelity Signal Quality Measurements of Digital Signals
-   Up to 5 GS/s Sample Rate Provides High Resolution Analog Views of Digital Signals
-   Advanced Digital Oscilloscope Triggering Helps Find Elusive Analog Anomalies in Digital Signals

**Specifications**

-   Bandwidth (at probe tips): 100 mV to 10 V range: 1 GHz; 50 mV to 99.8 mV range: 900 MHz; 20 mV to 49.8 mV range: 600 MHz
-   Memory Depth: 15,000 samples per channel in all modes
-   Number of Mainframe Slots Required: 2
-   Vertical System
-   Input Sensitivity Range: 10 mV to 100 V full scale.
-   Vertical Resolution: 8-Bit (256 levels).
-   DC Gain Accuracy: ±1.5% of full scale range.
-   Analog Bandwidth Selections: 20 MHz, 250 MHz, and Full.
-   Input Coupling: AC, DC or GND.
-   Input Impedance Selections: 1 MΩ in parallel with 10 pF, or 50 Ω
-   AC Coupled Lower Frequency Limit: ≤10 Hz when AC 1 MΩ coupled, ≤200 kHz when AC 50 Ω coupled
-   Maximum Input Voltage at Probe Connector: 300 VRMS, but no greater than ±420 Vp (1 MΩ or ground input coupling)

**Acquisition System**

-   Sample Rate Range: 200 ps to 200 ms in 1, 2.5, 5 sequence.
-   Timebase Accuracy: ±100 ppm over any interval ≥1 ms
-   Record Length Range: 512 to 15,000 samples per channel in all modes
-   Acquisition Modes: Single-shot, repetitive

**Trigger System**

-   Trigger Modes: Normal, auto
-   Trigger Position: Anywhere in the acquired record (pre-fill can be set anywhere from 0% to 100%)
-   Trigger Types: Edge, pulse width, timeout, glitch, runt, slew rate, logic pattern, setup-and-hold violation
-   Setup-and-hold Trigger: Triggers on violations of both setup time and hold time between clock and data which are on separate input channels; setup time settable from –100 ns to +100 ns in 200 ps increments; hold time settable from –1 ns to +102 ns; minimum settable window of setup time + hold time is 2 ns

**Applications**

-   Digital Hardware Verification and Debug
-   Monitor & Measure Digital Hardware Performance

The Tektronix TLA7E2 is a 4-Channel DSO module with a 1 GHz bandwidth, 5 GS/s sample rate, and 15 K memory depth.

The TLA700 Series offers a range of digitizing oscilloscope modules that provide the acquisition capabilities of the world’s best digitizing oscilloscopes, tightly integrated with the TLA700 logic analyzers. The 2 and 4 channel digitizing oscilloscope modules available in the TLA700 Series offer sample rates of up to 5 GS/s and bandwidths of up to 1 GHz, with 15 Kb memory depth per channel at all times.

The digitizing oscilloscope modules offer precise time correlation and flexible cross-triggering with other installed modules.

This enables you to see the quality of critical signals time-correlated with the digital signals represented by the logic analyzer modules.

These modules offer the triggering you expect from a Tektronix digital oscilloscope: Pulse Width, Runt, Glitch, Slew Rate, Logic Pattern, Setup-and-Hold Violation, Edge and Timeout.

## Details

- **Price:** 0.0 USD - 337.5 USD
- **Vendor:** Tektronix
- **Type:** Logic Ana
- **Tags:** Analyzers, Logic, Manufacturers, product_manual_group_1, Product_used, Signal Generators, Tektronix

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 225.00 USD | In stock |
| NIST Traceable with Full Data | 300.00 USD | In stock |
| ISO IEC 17025 Accredited | 337.50 USD | In stock |

## Images

- TLA7E2 Tektronix Logic Analyzer Used

---

> Source: [ValueTronics](https://valuetronics.com/products/tla7e2-tektronix-logic-analyzer-used)
> Updated: 2026-05-21