# 3765 Associated Research HiPot Used

**Additional Features:**

-   5KV AC, 6KV DC Hipot Tester
-   RS-232 interface standard for entry-level automation
-   Patented SmartGFI® safety circuit protects the operator from shock hazards
-   Patented VERI-CHEK® feature prompts users through steps to validate the instrument’s operation
-   Patented CAL-ALERT® feature alerts the operator that the tester is due for re-calibration
-   Built-in adjustable Continuity test for checking basic continuity
-   Graphic LCD provides intuitive menu system to simplify the entire testing process from set-up to results
-   Remote Safety Interlock feature prevents the high-voltage from being activated without the interlock enabled
-   10 Memories with 3 Steps per memory for storing and recalling test parameters
-   PLC Remote Control for simple remote operation
-   Interconnects with a HYAMP III Associated Research Ground Bond tester to form a complete test system
-   Digitally controlled arc detection circuit allows the operator to program sensitivity levels for detecting arcs
-   Minimum and maximum trip settings for safer and more accurate testing
-   Comes complete with an adapter box for products terminated in a line cord

**Input Specifications**

-   Voltage: 115/230 VAC ± 10%, user selectable
-   Frequency: 50/60 Hz ± 5%
-   Fuse: 3.15 A, fast acting 250 VAC

**Dielectric Withstand Test Mode**

-   Output Rating 5000 V @ 20 mA AC; 6000 V @ 7.5 mA DC
-   Voltage Setting Range: 0 - 5.00 KV AC; 0 - 6.00 KV DC
-   Resolution: 0.01 KV
-   Accuracy: ± (2% of setting + 5 V)
-   Maximum Limit AC Range: 0.00 - 20.00 mA
-   Resolution: 0.01 mA
-   DC Range: 0 - 7500 μA
-   Resolution: 1 μA
-   Accuracy: AC and DC ± (2% of setting + 2 counts)
-   Minimum Limit AC Range: 0.000 - 9.999 mA
-   Resolution: 0.001 mA
-   DC Range: 0.0 - 999.9 μA
-   Resolution: 0.1 μA
-   Accuracy: AC and DC ± (2% of setting + 2 counts)
-   Arc Detection: Range: 0 - 9, 0 disabled
-   Ground Fault Interrupt: GFI Trip Current: 450 μA max (AC or DC); HV Shut Down Speed: < 1ms

**Current Display Auto Range**

-   AC Range 1: 0.000 - 3.500 mA
-   Resolution: 0.001 mA
-   Range 2: 3.00 - 20.00 mA
-   Resolution: 0.01 mA
-   DC Range 1: 0.0 μA - 350.0 μA
-   Resolution: 1: 0.1 μA
-   Range 2: 0.300 mA - 3.500 mA
-   Resolution: 0.001 mA
-   Range 3: 3.00 mA - 7.50 mA
-   Resolution: 0.01 mA
-   Accuracy: All Ranges ± (2% of reading + 2 counts)

-   DC Output Ripple: ≤ 5% Ripple RMS at 6 KV DC @ 7.5 mA, Resistive Load
-   Discharge Time: ≤ 200 ms
-   The maximum capacitive load vs output voltage:
-   0.20 μF < 1 KV 0.050 μF < 4 KV
-   0.10 μF < 2 KV 0.040 μF < 5 KV
-   0.06 μF < 3 KV 0.015 μF < 6 KV
-   AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5
-   Output Frequency: Range: 50 or 60 HZ, User Selectable
-   Output Voltage Regulation: ± (1% of output + 5 V) from no load to full load and over input voltage range.

**Dwell Timer** 

-   Range: AC 0, 0.3 - 999.9 sec (0 = Continuous); DC 0, 0.4 - 999.9 sec (0 = Continuous)
-   Accuracy: ± (0.1% of reading + 0.05 sec)

**Ramp Timer**

-   Range: Ramp-Up: 0.1 - 999.9 sec
-   Ramp-Down: AC 0.0 - 999.9 sec
-   DC 1.0 - 999.9 sec (0=OFF)
-   Accuracy: ± (0.1% of reading + 0.05 sec)

-   Ground Continuity Current: DC 0.1 A ± 0.01 A, fixed
-   Ground Continuity Range: 0.0 Ω - 1.50 Ω
-   Maximum Limit Resolution: 0.01 Ω
-   Minimum Limit Accuracy: ± (3% of setting + 0.02 Ω)
-   Ground Continuity Range: 0.0 Ω - 0.50 Ω
-   Auto Offset Resolution: 0.01 Ω
-   Accuracy: ± (3% of setting + 0.02 Ω)

**Insulation Resistance Test Mode**

**Voltage Setting**

-   Range: 30 - 1000 VDC
-   Resolution: 1 V
-   Accuracy: ± (2% of setting + 5 V)

**Resistance Display**

-   Range: 1 - 9999 MΩ (4 Digit, Auto Ranging)
-   Resolution: 500 VDC - 1000 VDC
-   0.001: 1.000 - 9.999 MΩ
-   0.01: 10.00 - 99.99 MΩ
-   0.1: 100.0 - 999.9 MΩ
-   1: 1000 - 9999 MΩ
-   Accuracy: ± (2% of reading + 2 counts) at test voltage; 500 - 1000 V and 1 - 999.9 MΩ
-   ± (5% of reading + 2 counts) at test voltage
-   500 - 1000 V and 1000 - 9999 MΩ
-   ± (8% of reading + 2 counts) at test voltage
-   30 - 500 V and 1 - 1000 MΩ

**Maximum Limit**

-   Range: 0, 1 - 9999 MΩ (0=OFF)
-   Resolution: 1 MΩ
-   Accuracy: Same as Resistance Display

**Minimum Limit**

-   Range: 1 - 9999 MΩ
-   Resolution: 1 MΩ
-   Accuracy: Same as Resistance Display

**Ramp Timer**

-   Range: Ramp-Up: 0.1 - 999.9 sec
-   Ramp-Down: 1.0 - 999.9 sec (0=OFF)
-   Resolution: 0.1 sec
-   Accuracy: ± (0.1% of reading + 0.05 sec)

**Delay Timer**

-   Range: 0, 0.5 - 999.9 sec (0 = Continuous)
-   Resolution: 0.1 sec
-   Accuracy: ± (0.1% of reading + 0.05 sec)

-   GFI Trip Current: 450 μA max
-   HV Shut Down Speed: < 1 ms

**General Specifications**

-   Mechanical: Bench or rack mount with tilt up feet
-   Dimensions: (W x H x D) 8.46 x 3.5 x 14.57 in.; (215 x 89 x 370 mm)
-   Interface: RS-232 interface standard for entry-level automation
-   Memory: 10 Memories, 3 steps per memory

The Associated Research 3765 Hypot III is a bench top Dielectric Withstand tester with an enhanced graphic LCD. The 3765 features an RS-232 interface for entry-level automation.

## Details

- **Price:** 0.0 USD
- **Vendor:** Associated Research
- **Type:** Hipot
- **Tags:** Associated Research, Hipot, Manufacturers, Other Equipment, product_manual_group_1, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |