# M150AC Rod L Electronics HiPot Used

**Additional Features:**

-   Safe, Fast, Efficient
-   Fully programmable test parameters
-   Digital Display
-   Resolution of programmable test parameters is 0.5%
-   Performs an AC dielectric strength (Hipot) test concurrent with a ground continuity test
-   Applies a test potential of up to 5000 VAC at 50 milliamps (user programmable)
-   Performs tests in full compliance with UL, VOE, BSI, IEC, CSA, and other test standards

**Specifications**

-   Output Test Voltage: 100 VAC-5K VAC\*
-   Output Voltage Ramp Time: 50 V/sec to 5kV/sec\*
-   Total Current Trip Point: 50 mA (maximum)\*
-   Real Current Trip Point: 5 mA (maximum)\*
-   Under Current Trip Point: 5 mA (maximum)\*
-   Test Time: 1 sec - 100 sec\*
-   \*All of the above are User Programmable
-   Shutdown Time: 2 milliseconds
-   Arc Detection: Arc duration 1OµS or greater
-   Ground Continuity: Low current (1.5 Amp @ 1.5V)
-   Input Power Required: 115/230 VAC ± 10%, 47-63 Hz, 250 watts maximum, 30 watts typical
-   Dimensions: 16.75" x 7.00" x 18.38" (43cm x 18cm  x 47cm)

IEEE-488 BUS-compatible - enables data logging during each test, and remote programming of:

-   Test Voltage
-   Test Time
-   Voltage Ramp Rate
-   Real Current Trip Point
-   Total Current Trip Point
-   Under Current Trip Point

Detects and indicates the following events:

-   Test Ready (Security Chassis Ground Sensed)
-   Test in Progress
-   Test Passed
-   Test Failed:
-   Arcing
-   Excessive Total Leakage Current
-   Excessive Resistive Leakage Current
-   Under Current
-   Lack of adequate Chassis Ground

**Superior Safety Features**

-   Visual and Audible alert indicating Hipot test in progress
-   Low Current Security Chassis Ground Circuit (ensures Device Under Test has ground connection of o.sn between chassis and power cord ground pin)
-   Fast HV shutdown within 2 milliseconds of HV test automatically on test failure or on command

**IEEE-488 BUS Programming**

The Model M150AC Hipot Test System, when operated via the Model M1088C IEEE-488 BUS INTERFACE, functions as both a " Talker "(T) and a "Listener" (L) in conjunction with the following signals:

-   Output Voltage (T/L)
-   Output Voltage Ramp Rate (L)
-   Test Time (L)
-   Total Current Trip Point (L)
-   Total Current Magnitude (T)
-   Real Current Trip Point (L)
-   Real Current Magnitude (T)
-   Under Current Trip Point (L)
-   Test Status: Ready (T); In -Progress (T); Passed (T); Failed (T)
-   Type of Failure (T)
-   Start (L)
-   Stop (L)
-   Reset (L)

These signals can also be controlled using any controller capable of inputting and outputting digital and analog signals.

## Details

- **Price:** 0.0 USD - 175.0 USD
- **Vendor:** Rod L Electronics
- **Type:** Hipot
- **Tags:** Hipot, Manufacturers, Other Equipment, product_manual_group_1, Product_used, Rod L Electronics

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 105.00 USD | In stock |
| NIST Traceable with Full Data | 126.00 USD | In stock |
| ISO IEC 17025 Accredited | 175.00 USD | In stock |

## Images

- M150AC Rod L Electronics HiPot Used

---

> Source: [ValueTronics](https://valuetronics.com/products/m150ac-rod-l-electronics-hipot-used)
> Updated: 2026-05-21