# Anritsu ML2407A Single Input N-CDMA Power Meter (Pre-Owned)

# Anritsu ML2407A Single Input N-CDMA Power Meter (Pre-Owned)

## Key Features At A Glance

-   Graphics display, up to 100k samples/sec, profiles cellular, PCS, radar, aircraft-control and telemetry signals
-   On-pulse measurements over more than 80 dB dynamic range with TTL and edge-based triggering
-   GPIB (IEEE-488.2/IEC-625), RS-232, and parallel printer output standard for ATE and remote control
-   MA2400A/B sensors with built-in EEPROM for factory cal-factor data plus six user calibration-factor tables
-   Available as single- or dual-input meters, in standard and NCDMA configurations
-   Rugged, splash- and rain-resistant chassis built to MIL-T28800E, Type 3, Class 5
-   Optional NiMH battery delivers 6 hours of continuous operation for field use
-   Frequency coverage from 100 kHz to 50 GHz, sensor dependent

The Anritsu ML2400A Series is a family of RF and microwave power meters that combine speed, accuracy, sensitivity, a graphics display, voltage measurement, and portability in a single instrument. Available with single or dual sensor inputs, the series measures average, peak, and pulsed power using Anritsu MA2400A/B Series power sensors across a frequency range that extends, sensor dependent, from 100 kHz to 50 GHz. From its Preset condition the meter delivers a power measurement with a minimum of keystrokes, and basic measurements can be made with just two operations: a sensor zero and entry of the measurement frequency.

The series is applied to the precise characterization of amplifier output power and gain, where the dual-channel ML2438A measures gain and output power simultaneously using two independent signal channels that eliminate multiplexing. It supports average power measurements on N-CDMA (IS-95), WCDMA, and other digitally modulated carriers such as HDTV, DAB, and QAM modulated radio links, and it captures and displays individual time slots of TDMA systems including GSM, DCS-1800, DECT, IS-136, PCS-1900, and PHS. The graphics display also profiles cellular, PCS, radar, aircraft control, and telemetry signals, and the Power vs Time mode provides a strip-chart display of RF power variation over windows from one minute to 24 hours.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned instrument we sell is inspected and functionally verified in-house before it ships, while new units leave our facility factory-sealed exactly as received from the manufacturer. Because we hold our own stock, the power meter you order is on our shelves and ready to move.

## Compare Other Models in This Series

The Anritsu ML2400A Series comprises four power meter models that share a common chassis, graphics display, and sensor compatibility while differing in input count and target measurement class. The ML2437A and ML2438A provide standard power measurement with single and dual sensor inputs respectively, while the ML2407A and ML2408A are NCDMA power meters offered in single- and dual-input configurations.

Every model in the series works with the MA2400A/B Series power sensors and reads calibration factor and linearity data from each sensor's internal EEPROM, simplifying setup and reducing human error. The dual-input models present two independent signal channels, eliminating multiplexing so that two measurements such as amplifier output power and gain can be taken simultaneously.

Each model in the ML2400A Series links to its own dedicated product page with pre-owned pricing matched to that listing. Select the single-input, dual-input, or NCDMA configuration your application requires, and review that model's page for its specific condition and availability.

The primary differences across the series fall along two axes: input count and measurement class. Single-input models (ML2437A, ML2407A) accept one sensor, while dual-input models (ML2438A, ML2408A) accept two independent sensors. The standard models, ML2437A and ML2438A, provide a channel bandwidth of 100 kHz nominal, whereas the NCDMA models, ML2407A and ML2408A, provide 1.4 MHz nominal channel bandwidth.

The NCDMA models add average power, peak power, and crest factor measurement on N-CDMA signals, and are intended for use with the fast diode sensors required for narrow-pulse and IS-95 work. Zero-set, drift, and noise figures also differ between the standard models (less than 0.5%) and the NCDMA models (less than 1.8%). Consult the comparison table below for the per-model figures.

Model

Inputs

Channel Bandwidth

N-CDMA Measurements

**ML2407A**

Single

1.4 MHz nominal

Yes

ML2437A

Single

100 kHz nominal

No

ML2438A

Dual

100 kHz nominal

No

ML2408A

Dual

1.4 MHz nominal

Yes

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   Power cord for destination
-   One 1.5m sensor cord per meter input
-   Operation Manual
-   Certificate of Calibration

## Product Core & Specifications

Specification

Value

General

Frequency Range

100 kHz to 50 GHz (sensor dependent)

Power Sensors

Meter specifications apply to MA2400A/B Series Power Sensors. Compatible with MA and MP Series sensors.

Power Measurement Range

\-70 to +47 dBm (0.1 nW to 50 W), sensor/attenuator dependent. Use couplers for higher power levels.

Voltage Measurement Range

0.00 to 20.00 V, nominal

Display Range

\-99.999 to +99.999 dB

Display Resolution

Selectable from 0.1 dB to 0.001 dB, limited to 0.01 dB in graphical display modes; Linear power units, 3 to 6 digit, 1 - 3 digits selectable to right of decimal nW - W; Voltage, 1 - 2 digits selectable to right of decimal.

Offset Range

\-99.99 to +99.99 dB. Fixed value or frequency dependent table.

Display Units

dBm, dB, dBr, dBmV, dBuV, W, %, Volts

Instrumentation Accuracy

< 0.5 %

Zero Set and Drift

ML2437/8A < 0.5 %, ML2407/8A < 1.8 % of full scale in most sensitive range, measured over one hour with maximum averaging after one hour warm up at constant temperature.

Noise

ML2437/8A < 0.5 %, ML2407/8A < 1.8 % of full scale in most sensitive range, both measured over a one minute interval with maximum averaging, two standard deviations at constant temperature after one hour warm up, typical. MA2470A Series, 20 pW typical.

Sensor Dynamic Range

MA2420A/B Series Thermal Sensors

50 dB

MA2440A Series High Accuracy Power Sensors

87 dB CW, > 57 dB Peak

MA2460A/B Series Fast Diode Sensors

80 dB

MA2470A Series Power Sensors

90 dB CW, > 60 dB Peak

MA2480A Series Universal Sensors

80 dB

1.00 mW Power Reference

Frequency

50 MHz nominal

Output Level

1.00 mW, ± 1.2%/Year, ± 0.9% RSS, NIST Traceable

Maximum Input

\+ 20 dBm continuous or peak, ± 50 V dc

VSWR

< 1.04

Connector

Type N female

Sensor / Channel Control

Operating modes

Readout, dual channel. RF power or voltage. Power Versus Time: single channel graphic of readout data. Profile: single channel RF peak power graphic display for analysis of repetitive pulse or transient waveforms. Source Sweep: single channel power sweep or frequency sweep. NCDMA Average Power, Peak Power and Crest Factor - ML2407/8A only.

Range Hold

Current range or selectable 1 through 5.

Averaging

Auto-averaging

Automatically increases moving averaging at low power ranges.

Averaging Types

Auto, Manual (Moving, Repeat)

Manual Average Range

1 to 512

Low-Level Averaging

Low, Medium, and High settings apply post average low pass filter to improve visibility at high display resolution.

Limit Lines

Fixed value high and low limits with audible, rear panel TTL output, and/or visible Pass/Fail alarm indication. Failure indication can latch for transient failure detection.

Cursors

Two manually adjustable cursors with power, delta cursor power, between cursor power average, and delta time readout display.

Delta t Resolution

0.5% of display period or 100 ns

Triggering

Trigger Sources

Internal, External TTL, GPIB, Manual, Continuous

Delay Range

0.0 to 999.0 Milliseconds

Delay Resolution

0.5% of display period or 100 ns

Internal Trigger Range

\-15 to +20 dBm, all diode sensors. Selectable to -25 dBm

Internal Trigger Level Accuracy

1.0 dB, typical

External Trigger Range

TTL rising or falling edge trigger. BNC input

Manual Trigger

Front Panel Softkey

Channel Bandwidth

ML2437/38A

100 kHz nominal

ML2407/08A

1.4 MHz nominal

System Configuration

Display

LCD Graphic display with backlight and adjustable contrast.

Save/Recall

10 storage registers plus RESET default settings

Secure Mode

Erases memory information upon power ON. Default condition is Secure Mode OFF.

Rear Panel Cal Factor Voltage Input (BNC)

Operating Modes

Voltage: Display voltage reading on selected channel; Voltage proportional to frequency for sensor calibration factor compensation; Blanking Input: TTL levels only. Selectable positive or negative polarity.

Input Range

0 to 20 V

Resolution

0.5 mV

Control

Adjustable voltage to frequency Relationship

Analog Output (BNC)

Outputs

Two outputs configurable to Log or Lin

Operating Modes

Analog Out: Selectable channel adjusted for calibration factors and other power reading correction settings. Pass/Fail: Selectable TTL High or Low. Channel output: Near real time analog. Uncalibrated. AC Modulation Output: Output 1 only. Dwell Output: Output 2 only.

Output Range

\-5.0 to 5.0 V

Resolution

0.1 mV

Trigger Input

Operating Modes

External TTL or RF Blanking

Interfaces

GPIB Interface

IEEE-488.2 and IEC-625

RS-232

Supports software download and modem dial-out.

Parallel Printer Output

Compatible with Deskjet 540 and 340 Models. Other 500 Series and 300 Series and later are typically compatible. Also Canon BJC 80. See manual for DIP switch settings.

General Specifications

General

MIL-T28800E, Type 3, class 5, Style E

> **Important:** Power reference maximum input: +20 dBm continuous or peak, ±50 V DC.

> **Important:** The meter requires an MA2400A/B Series power sensor to make measurements. Standard delivery includes a power cord, a 1.5 m sensor cord per meter input, an Operation Manual and a Certificate of Calibration, but does not include a power sensor; the appropriate sensor must be ordered separately.

> **Important:** MA2460A/B Fast Diode Sensors (MA2468A, MA2469B) must be used with the ML2407/08A Power Meters for N-CDMA and Fast Pulse measurements.

> **Important:** Options 1 to 5 are mutually exclusive for any given unit.

> **Important:** Options 25, 26 and 27 (30 m, 50 m and 100 m sensor cables) cannot be used with the ML2407/8A.

> **Important:** Front panel label warns: DO NOT EXCEED SENSOR MAX PWR.

> Recommended pairing: the ML2400A Series is designed to function with Anritsu 68B/69A synthesized sweep generators to form an integrated test solution for swept power and frequency measurements.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   ValueTronics warranty included.
-   Functional verification included.
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Anritsu
- **Type:** Rfp Met
- **Tags:** Anritsu, Anritsu Corporation, Inc., Manufacturers, Meters & DAQ, ML2407, ML2407A, Model 2407, Pow Met, Pre-Owned, product_manual_group_1, Product_used, RF Power, Rfp Met

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Anritsu ML2407A Single Input N-CDMA Power Meter (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/ml2407a-anritsu-rf-power-meter-used)
> Updated: 2026-06-03