# Agilent U2702A 200 MHz USB Modular Oscilloscope (Pre-Owned)

# Agilent U2702A 200 MHz USB Modular Oscilloscope (Pre-Owned)

## Key Features At A Glance

-   Bandwidth from 100 MHz (U2701A) to 200 MHz (U2702A) across the series
-   Up to 1 GSa/s maximum sample rate (two channels interleaved; 500 MSa/s per channel)
-   Up to 32 Mpts standard waveform memory (up to 64 Mpts in single-shot)
-   Dual-play function: run standalone or in a modular product chassis cardcage
-   Hi-Speed USB 2.0 interface; USBTMC 488.2 class device for automated systems
-   Advanced triggering including edge, pulse width, and TV
-   Four waveform math functions including FFT standard
-   Compact, portable module design

The Agilent U2701A and U2702A are USB modular oscilloscopes that combine a set of essential features for analyzing designs in an affordable way. They are offered in two bandwidths — 100 MHz on the U2701A and 200 MHz on the U2702A — and acquire simultaneously on two channels, Ch 1 and Ch 2. Each unit includes standard debugging capability such as advanced triggering, automatic measurements, and math functions including FFT.

An oscilloscope captures voltage waveforms over time, letting an engineer see a signal's amplitude, frequency, timing, and shape. The U2701A and U2702A connect to a PC through a Hi-Speed USB 2.0 interface for easy plug-and-play setup, which makes them suited to the education, design validation, and manufacturing industries. The dual-play function lets a unit serve as a standalone instrument or scale up within a cardcage alongside additional scopes or other Agilent USB modular products, providing a complete solution for system development.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

## Brand Heritage

Agilent Technologies was established in 1999 as a spin-off of Hewlett-Packard's test and measurement business. In 2014, Agilent's electronic measurement business was separated again to form Keysight Technologies, under which this product line was subsequently offered.

## Compare Other Models in This Series

The U2701A/U2702A USB Modular Oscilloscope family consists of two models that share a common architecture and differ primarily in bandwidth. Both acquire simultaneously on two channels, reach up to 1 GSa/s when channels are interleaved, and carry up to 32 Mpts of standard waveform memory.

Both models offer the dual-play function, allowing each to run as a standalone instrument over Hi-Speed USB 2.0 or to be installed in a modular product chassis for system expansion. Advanced triggering, four math functions with FFT, and the Agilent Measurement Manager software are standard across the family.

Each model in this family is listed on its own dedicated product page, with pricing matched to the pre-owned unit you select. Choose the model whose bandwidth fits your application, then open the listing for your preferred condition.

The two models are separated by bandwidth: the U2701A provides DC to 100 MHz with a calculated rise time of 3.5 ns, while the U2702A provides DC to 200 MHz with a calculated rise time of 1.75 ns. Sample rate, memory depth, vertical resolution, and trigger capability are otherwise common to both.

The included probe tracks the bandwidth tier as well: the U2701A ships with 10:1 150 MHz passive probes (N2862A) and the U2702A ships with 10:1 300 MHz passive probes (N2863A). The comparison table below summarizes these per-model differences.

Model

Bandwidth

Rise Time

Max Sample Rate

**U2702A**

200 MHz

1.75 ns

1 GSa/s

U2701A

100 MHz

3.5 ns

1 GSa/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   12 V, 2 A AC/DC Power adapter
-   Power cord
-   USB Standard A to Mini-B interface cable
-   2 x 10:1 Passive probe 300 MHz 1.2m, N2863A
-   L-Mount kit (used with modular product chassis)
-   Agilent Automation-Ready CD-ROM (contains the Agilent IO Libraries Suite)
-   Agilent USB Modular Products Quick Start Guide
-   Agilent USB Modular Products Reference CD-ROM
-   Agilent USB Modular Products Quick Reference Card
-   Certificate of Calibration

## Product Core & Specifications

Specification

Value

Vertical System: Oscilloscope Channels

Bandwidth (–3 dB)

DC to 200 MHz

Scope channels

Ch 1 and Ch 2 simultaneous acquisition

AC coupled

3.5 Hz to 200 MHz

Calculated rise time (= 0.35/bandwidth)

1.75 ns

Single-shot bandwidth

200 MHz

Range

2 mV/div to 5 V/div (1 MΩ)

Maximum input

CAT I 30 Vrms, 42 Vpk

Offset range

±4 div (Example: ±8 mV on 2 mV/div; ±20 V on 5 V/div)

Dynamic range

±4 div

Input impedance

1 MΩ: ≈ 16 pF

Coupling

AC, DC, Ground

BW limit

≈ 25 MHz

Standard probes

10:1 Passive probe 300 MHz 1.2 m

ESD tolerance

±2 kV

Noise peak-to-peak

3 mVpp

DC vertical offset accuracy

≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; > 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value

DC vertical gain accuracy

±4.0% of full scale

Scope channel triggering trigger sensitivity

< 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div

Single-cursor accuracy

±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~2 LSB)}

Dual-cursor accuracy

±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)}

Acquisition: Oscilloscope Channels

Real time sample rate — 2 channels interleaved

1 GSa/s

Real time sample rate — each channel

500 MSa/s

Standard memory depth — 2 channels interleaved (Normal / Single-shot)

32 Mpts / 64 Mpts

Standard memory depth — each channel (Normal / Single-shot)

16 Mpts / 32 Mpts

Vertical resolution

8 bits

Peak detection

Yes

Averaging

Any number from 1 to 999

Filter

Sin(x)/x interpolation for time base 1 ns to 100 ns

Sweep modes

Auto, normal, single

Horizontal

Range

1 ns/div to 50 s/div

Time base accuracy

20 ppm

Delay range

Pre-trigger: –100 %; Post-trigger: +100 %

Modes

Main, roll, XY

XY

Yes

Reference position

Center

Trigger System

Sources

Ch 1, Ch 2, Ext (not applicable for TV trigger)

Modes

Normal, single, auto trigger

Holdoff time

60 ns

Selections

Edge, pulse width, TV

Edge

Triggers on a rising or falling edge, alternating, or either edge of any source

Pulse width

Triggers on a pulse width greater than, equal to, or less than a specified time limit, with time limits ranging from 16 ns to 10 s. Minimum lower limit: 8 ns; Minimum upper limit: 16 ns; Maximum pulse width setting: 10 s

TV

Triggers on one of three standard television waveforms: NTSC, PAL, SECAM. TV trigger sensitivity: 0.6 division of sync signal. Modes supported include Field 1, Field 2, all fields, or any line within a field.

Autoscale

Single-button automatic setup of all channels

Oscilloscope Channel Triggering

Range (internal)

±4 div from center screen

Coupling

AC (< 15 Hz); LF reject (~ 35 kHz); HF reject (~ 35 kHz)

External (EXT) Triggering

Input impedance

1 MΩ: ≈ 16 pF

Maximum input

CAT I 30 Vrms, 42 Vpk

Range

DC coupling: trigger level ±1.25 V and ±2.5 V

EXT trigger pulse width

\> 2.5 ns

Trigger level sensitivity (±1.25 V range)

DC to 100 MHz: 100 μV; > 100 MHz: 200 μV

Trigger level sensitivity (±2.5 V range)

DC to 100 MHz: 250 μV; > 100 MHz: 500 μV

Display

Interpolation

Sin(x)/x

Display types

Dots and vectors

Persistence

Off, infinite

Format

XY, roll

Measurement Features

Automatic measurements

Measurements are continuously updated. Cursors track last selected measurement.

Voltage

Peak-to-peak, maximum, minimum, average, amplitude, top, base, Vrms, overshoot, preshoot, crest, standard deviation, cycle RMS, RMS AC

Time

Frequency, period, +width, –width, +duty cycle, –duty cycle, rise time, fall time, delay, phase

Frequency

Maximum peak

Cursors

Modes: Manual; Type: Time, voltage and frequency (FFT); Measurements: DT, DV, frequency, Peak Scan (FFT), DPeak

Math functions

Add, subtract, multiply, FFT, divide

FFT

Points

1250 points (for 500 ns and above)

Source of FFT

Source channels 1 or 2

Window

Hanning, Hamming, Blackman-Harris, Rectangular, Flattop

Noise floor

–50 dB to –90 dB depending on averaging

Amplitude

Display in dBV

Maximum frequency

250 MHz

General / Product Characteristics

Remote interface

Hi-Speed USB 2.0; USBTMC 488.2 Class device

Power consumption

+12 VDC, 2 A; Installation Category III

Operating temperature

0 °C to +50 °C

Operating humidity

20% to 85% RH (non-condensing)

> **Important:** Maximum input is CAT I 30 Vrms, 42 Vpk. Under standalone use, measurement is limited to CAT I 30 Vrms; for high-voltage measurement up to CAT I 300 Vrms, the L-Mount kit must be installed on the module and screwed to the product chassis for proper grounding, and the provided 10:1 probes (N2862A/N2863A) must be used to avoid damaging the instrument.

> **Important:** The Hi-Speed USB 2.0 / USBTMC 488.2 remote interface is compatible with Microsoft Windows operating systems only and requires a direct USB connection to the PC so the appropriate driver can be installed in the USB modular instrument.

> Recommended pairing: use the Agilent U2781A USB Modular Product Chassis to operate the oscilloscope in a cardcage with additional modules, per the dual-play configuration.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD - 262.5 USD
- **Vendor:** Agilent
- **Type:** Dig Oscilloscope
- **Tags:** Agilent, Agilent Keysight, Agilent Technologies, Dig Oscilloscope, Digital, Inc., Keysight, Keysight Technologies, Manufacturers, Model 2702, Oscilloscopes, Pre-Owned, product_manual_group_1, Product_used, U2702, U2702A

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 187.50 USD | In stock |
| NIST Traceable with Full Data | 225.00 USD | In stock |
| ISO IEC 17025 Accredited | 262.50 USD | In stock |

## Images

- Agilent U2702A 200 MHz USB Modular Oscilloscope (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/u2702a-agilent-digital-oscilloscope-used)
> Updated: 2026-06-03
