# Keysight 86100D DCA-X Wide Bandwidth Oscilloscope Mainframe (Pre-Owned)

# Keysight 86100D DCA-X Wide Bandwidth Oscilloscope Mainframe (Pre-Owned)

## Key Features At A Glance

-   Performs precision measurements on high-speed digital designs from 50 MBd to more than 80 GBd
-   Up to 16 channels with simultaneous acquisition
-   Modular plug-in architecture supports electrical, optical, optical/electrical, TDR, clock recovery, and precision waveform analyzer modules
-   Time interval accuracy of 1 ps + 1.0% of Δ time reading or 8 ps, whichever is smaller
-   Optional integrated Precision Timebase (PTB) for low-jitter measurements down to characteristic 90 fs at trigger frequencies above 9 GHz
-   Pattern lock record length up to 32 M samples in FlexDCA (pattern, channel count, and available memory dependent)
-   Standard Trigger (STR) or Enhanced Trigger (ETR) configurations to match application requirements
-   Supports a broad range of compliance and analysis software including PAM-N, jitter, S-parameter, and IEEE/OIF-CEI applications

The Keysight 86100D DCA-X is a wide bandwidth oscilloscope mainframe that performs precision measurements on high-speed digital designs from 50 MBd to more than 80 GBd, with up to 16 channels acquired simultaneously. The mainframe accepts a wide range of plug-in modules covering electrical, optical, optical/electrical, TDR/TDT, clock recovery, and precision waveform analysis, making it the platform around which complete Digital Communications Analyzer solutions are built.

Applications described in the datasheet include optical transceiver design and production test, electrical ASIC/FPGA/IC design and characterization, and serial bus characterization, measurement, and troubleshooting via TDR/TDT and S-parameter measurements of channels, cables, and PCBs. The DCA-X family is positioned for engineers working on eye diagram analysis, jitter analysis, PAM-N signaling, and compliance testing against published industry standards.

ValueTronics International has supplied new and pre-owned test and measurement equipment to engineering teams across aerospace, telecommunications, semiconductor, and high-speed digital design since 1992. Our 86100D DCA-X inventory is housed and serviced at our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois, where every unit is processed, inspected, and prepared by experienced technicians before shipment. For instruments of this complexity — wide-bandwidth oscilloscope mainframes with modular electrical, optical, and precision-timebase configurations — that hands-on verification step is the difference between buying with confidence and buying from a drop-shipper. Our team can also confirm installed options, module compatibility, and software licensing before the unit ships, which is information drop-ship listings rarely provide accurately.

## Brand Heritage

The 86100D DCA-X traces its lineage through one of the most respected names in electronic test and measurement. Hewlett-Packard spun off its test and measurement business as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement division, which became Keysight Technologies. The 86100-series digital communications analyzer platform has continued forward across all three brand identities, with the 86100D representing the current generation of the mainframe under the Keysight name.

## Accessories Supplied

-   USB Keyboard and mouse
-   2.92 mm female-female connector saver (P/N 1250-4105) for trigger input
-   Nominal length jumper cable (with Option PTB, for precision timebase delay path)

## Product Core & Specifications

Category

Specification

Value

Temperature

Operating

10 to +40 °C (50 to +104 °F)

Non-operating

–40 to +65 °C (–40 to +158 °F)

Altitude

Operating

Up to 4,600 meters (15,000 feet)

Power (max)

100/120 Vac 50/60/400 Hz

With typical modules: 150 to 230 VA at 25°C

220/240 Vac 50/60 Hz

700 W maximum

Weight

Mainframe without modules

20.5 kg (43 lbs)

Typical module

1.2 kg (2.6 lbs)

Mainframe Dimensions (excluding handle)

Without front connectors and rear feet

221 mm (H) x 426 mm (W) x 530 mm (D) (7 in x 16.76 in x 20.9 in)

With front connectors and rear feet

234 mm (H) x 426 mm (W) x 601 mm (D) (9.23 in x 16.76 in x 23.67 in)

With front cover and rear feet

234 mm (H) x 426 mm (W) x 612 mm (D) (9.23 in x 16.76 in x 24.1 in)

Max Relative Humidity

—

80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C

Supply Voltage Variation

—

Can operate with supply voltage fluctuations up to ± 10% of the nominal voltage

Horizontal System (Time Base)

Scale factor minimum

100 fs/div

Scale factor maximum

1 s/div (250 ns/div with pattern lock)

Delay minimum

24 ns (40.1 ns default with pattern lock, 24 ns min)

Delay maximum

1000 screen diameters or 10 s whichever is smaller (1000 screen diameters or 25.401 μs whichever is smaller with pattern lock)

Time interval accuracy

1 ps + 1.0% of Δ time reading or 8 ps, whichever is smaller

Time interval resolution

≤ (screen diameter)/(record length) or 62.5 fs, whichever is larger

Jitter Mode

Time interval accuracy

1 ps (jitter mode operation)

Vertical System (Channels)

Number of channels

16 (simultaneous acquisition)

Vertical resolution (54xxx, 83xxx, 86xxx)

14 bit A/D converter (16 or more bits with averaging)

Vertical resolution (N10xx)

16 bit A/D converter

Record length (Legacy UI)

16 to 16 K samples

Record length (FlexDCA with pattern lock)

16 up to 32 M samples

Computer System

CPU

Intel Core i5 3550S CPU at 3.0 GHz

Mass storage

150 GB internal hard drive (default) or 80 GB removable hard drive (Option 090)

Operating system

Microsoft Windows 7 embedded standard (64 bit)

Display

Display area

210.4 mm x 157.8 mm (10.4 inch diagonal color active matrix LCD)

Resolution

1024 x 768 pixels

Persistence modes

Gray scale, color grade, variable, infinite

Front Panel I/O

Cal output

BNC (female) and test clip, banana plug

Trigger input

2.92 mm

USB

Three low-power USB 2.0 ports; 5.00 ± 0.25 V; 100 mA each

Precision timebase input (Option PTB only)

2.92 mm

Rear Panel I/O

Gated trigger input

TTL compatible

Video output

VGA, full color, 15 pin D-sub (female)

GPIB

Fully programmable, complies with IEEE 488.2 (optional, order 86100D-GPI)

RS-232

9 pin D-sub (male)

USB

Four USB 2.0 ports; 5.00 ± 0.25 V; 500 mA each

Precision timebase delay path (Option PTB only)

Two female SMA connectors, nominal length jumper cable included

**Important:** Option ETR is recommended when using a DCA module equipped with a rear panel trigger circuit such as the 54754A, 83496-series, or 86108-series.**Important:** Plug-in modules are sold separately and are required for the 86100D mainframe to perform measurements. The mainframe does not ship with measurement modules. Select compatible modules from the Module Selection Guide (e.g., 54754A, 86105C/D, 86108B, 86115D, 86116C, N1045A/B, N1046A, N1055A, N1060A).**Important:** Option ETR (Enhanced Trigger) is recommended when using a DCA module equipped with a rear panel trigger circuit such as the 54754A, 83496x, 86108x, etc.**Important:** Module triggering is not supported in either Option STR or Option ETR configurations; external connections between the module and the mainframe may be required.**Important:** External divided trigger (AC coupled) is not available with Option STR.**Important:** Option BFP requires Option 202. Options 200, 201, and SIM require hardware Option ETR (enhanced trigger). Option 300 requires Options 200 and ETR. Option 400 requires Microsoft Office Excel 2007/2010. For complete PAM4 analysis capability, Option 9FP requires Options 200/201/300/401.**Important:** The 86100D mainframe ships with a 2.92 mm female-to-female adapter (P/N 1250-4105) for the trigger and precision timebase ports.**Important:** For optimum performance, the instrument should have a complete verification of specifications once every twelve months.**Important:** For test adapters to connect to SFP+, QSFP+, fibre channel, PCIe and other interfaces, see adapter information from Wilder Technologies. Contact Keysight for connectivity and probing solutions not listed in the datasheet.Recommended pairing: when using the 86100D with modules equipped with a rear panel trigger circuit (54754A, 83496A/B, 86108A/B, N1060A), specify Option ETR. For lowest-jitter measurements at higher trigger frequencies, add Option PTB to extend divided-trigger operation to 32 GHz.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD - 840.0 USD
- **Vendor:** Keysight
- **Type:** Dig Oscilloscope
- **Tags:** 86100, 86100D, Agilent, Agilent Keysight, Agilent Technologies, Analyzers, Communication, consignment-active, Digital Storage Oscilloscope, DSO, Keysight, Manufacturers, Model 86100, Oscilloscope, Oscilloscopes, Pre-Owned, product_manual_group_1, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 560.00 USD | In stock |
| NIST Traceable with Full Data | 700.00 USD | In stock |
| ISO IEC 17025 Accredited | 840.00 USD | In stock |

## Images

- Keysight 86100D DCA-X Wide Bandwidth Oscilloscope Mainframe (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/86100d-agilent-communication-analyzer-used)