# Advantest R3961B 30 kHz to 3.6 GHz S-Parameter Test Set (Pre-Owned)

# Advantest R3961B 30 kHz to 3.6 GHz S-Parameter Test Set (Pre-Owned)

## Key Features At A Glance

-   Frequency range from 300 kHz to 3.6 GHz with 1 Hz resolution
-   High-speed measurement at 0.5 ms per point
-   Measures amplitude, phase, group delay, and impedance
-   Amplitude resolution of 0.001 dB; phase resolution of 0.01°
-   BASIC controller function with built-in arithmetic and FDD support
-   GPIB, parallel I/O, and RS-232C connectivity for external equipment
-   Compatible with R3961B/R3961BN S-parameter test sets for full S11/S12/S21/S22 measurement

The Advantest R3762AH is a quasi-microwave vector network analyzer covering 300 kHz to 3.6 GHz that quickly and accurately measures amplitude, phase, group delay, and impedance. The R3762AH provides three input terminals (Rch, Ach, Bch) and dual-channel display capability, supporting A/R, B/R, and A/B measurement formats with orthogonal, Smith chart, and polar coordinate display options.

A vector network analyzer is used by RF engineers to characterize how signals transmit through and reflect off RF components and networks. The R3762AH is suited for testing mobile radio communications components, with applications including measuring amplitude ripple and group delay ripple values in a given interval, and measuring filter bandwidths and Q=Δf/fo at an XdB-down point. These analytical functions are designed to improve measurement throughput.

ValueTronics is a specialist source for new and used test and measurement equipment, stocking instruments at our 20,000 square foot secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Equipment shipped from our facility is inspected and performance-tested in-house by our technicians before delivery, and we maintain calibration documentation pathways for customers whose quality systems require NIST-traceable or ISO 17025 records.

## Brand Heritage

Advantest Corporation is a Japanese test and measurement manufacturer that has operated under the Advantest name since 1985, when the company adopted its current branding from its prior name Takeda Riken. Advantest's instrument lines, including the R3762 vector network analyzer family, continue to be supported in the used market.

## Compare Other Models in This Series

The R3762 series consists of two quasi-microwave vector network analyzer models—the R3762AH and R3762BH—both covering 300 kHz to 3.6 GHz with 1 Hz frequency resolution and sharing the same 0.5 ms per point sweep speed. Both models measure amplitude, phase, group delay, and impedance using Advantest's analog and digital signal processing architecture.

The two models in the R3762 family differ primarily in channel configuration, measurement format support, and signal source output capability. They share identical input impedance (50 Ω), the same amplitude and phase measurement ranges, identical error compensation features, and the same external equipment connectivity (GPIB, parallel I/O, RS-232C).

Each pre-owned R3762 series unit listed below is its own product page with condition-matched pricing and a dedicated specification table. Use the comparison below to identify the specific model that matches your channel count and signal source output requirements, then select that model's page for full details.

The R3762AH provides two display channels and supports A/R, B/R, and A/B measurement formats with three input terminals (Rch, Ach, Bch). Its signal source output level ranges from 20 dBm to -5 dBm with 0.01 dB resolution, in single output format.

The R3762AH supports two display channels and three input terminals (Rch, Ach, Bch), enabling A/R, B/R, and A/B ratio measurements. The R3762BH supports two input terminals (Rch, Ach) with A/R format only. Both models offer two display channels.

Signal source output also differs between the two models. The R3762AH outputs 20 dBm to -5 dBm with 0.01 dB resolution in single output format, while the R3762BH outputs 13 dBm to -10 dBm with 0.01 dB resolution in dual output format. Review the per-model specification tables below to confirm which output configuration matches your application.

Model

Frequency Range

Display Parameters

Input Terminals

**R3961B**

300 kHz to 3.6 GHz

—

—

R3762AH

300 kHz to 3.6 GHz

A/R, B/R, A/B

3 (Rch, Ach, Bch)

R3762BH

300 kHz to 3.6 GHz

A/R

2 (Rch, Ach)

R3961BN

300 kHz to 2 GHz

—

—

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Specification

R3961B

Frequency range

300 kHz to 3.6 GHz

Test port impedance

50 Ω

Directivity

25 dB or more (300 kHz to 5 MHz); 30 dB or more at 25°C ±5°C; 35 dB or more (5 MHz to 1.3 GHz); 30 dB or more (1.3 GHz to 3.6 GHz)

Input port return loss

17 dB or more (300 kHz to 1.3 GHz); 12 dB or more (1.3 GHz to 3 GHz); 10 dB or more (3 GHz to 3.6 GHz)

Test port return loss

20 dB or more (300 kHz to 1.3 GHz); 18 dB or more (1.3 GHz to 3 GHz); 16 dB or more (3 GHz to 3.6 GHz)

Transmission amplitude

1.5 dBpp Typ

Transmission phase

10 degpp Typ

Reflection amplitude

1.5 dBpp Typ

Reflection phase

10 degpp Typ

RFIN to PORT 1, 2

6 dB Typ

RFIN to OUTPUT A

21 dB Typ

RFIN to OUTPUT A & B

22 dB Typ

RF destructive level

+27 dBm, ±30V DC max.

Test ports 1 and 2 isolation

90 dB or more

Coaxial switch reproducibility

±0.03 dB (at the tenth changeover)

**Important:** Test ports 1 and 2 isolation is 90 dB or more; coaxial switch reproducibility is ±0.03 dB at the tenth changeover.**Important:** S-Parameter Test Sets R3961B/3961BN: RF destructive level is +27 dBm, ±30V DC max. Exceeding these limits will damage the test set.**Important:** The R3961B/3961BN S-Parameter Test Sets connect to the R3762AH Network Analyzer to measure transmission/reflection characteristics; they contain the SWR bridge, power splitter, and switches required to measure S11, S12, S21, and S22 without changing the cable.**Important:** The R3951A S-Parameter Test Set is designed for use with the R3751AH Network Analyzer to measure the transmission and reflection characteristics of 2-port devices.Recommended pairing: connect the R3762AH to the Advantest R3961B (50 Ω, to 3.6 GHz) or R3961BN (75 Ω, to 2 GHz) S-parameter test set to measure S11, S12, S21, and S22 without changing cables. Test set RF destructive level is +27 dBm and ±30V DC maximum.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Advantest
- **Type:** Network Analyzer
- **Tags:** Advantest, Manufacturers, Other Equipment, product_manual_group_1, Product_used, Test Set

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Advantest R3961B 30 kHz to 3.6 GHz S-Parameter Test Set (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/r3961b-advantest-test-set-used)
> Updated: 2026-05-30