# Tektronix P6316 16-Channel Digital Probe for MSO2000 Series Oscilloscopes

# Tektronix P6316 16-Channel Digital Probe for MSO2000 Series Oscilloscopes

## Key Features At A Glance

-   16 digital channels broken out over two 2x8-pin headers (GROUP 1 and GROUP 2), eight signals per header row
-   Threshold voltage range of ±20 V with ±100 mV + 3% of setting threshold accuracy
-   Maximum nondestructive input signal of ±40 V p-p to the probe
-   Minimum detectable input pulse of 5 ns; minimum signal swing of 500 mV p-p
-   Input resistance of 101 kΩ with 8.0 pF input capacitance
-   Connects Tektronix MSO2000 Series mixed-signal oscilloscopes to digital buses and signals
-   Ships with interchangeable flying lead sets, micro grabber clips, and probe tips
-   Serial and parallel bus setup with Hex, Binary, and ASCII display formats

The Tektronix P6316 is a 16-channel digital probe that connects the Tektronix MSO2000 Series of mixed-signal oscilloscopes to the digital buses and signals on a target system. It breaks out its 16 data channels over two 2x8-pin headers, designated GROUP 1 and GROUP 2, where each header carries eight signal connections on one row and eight ground connections along the opposite row. A pair of interchangeable flying lead sets is included, each providing one ground connection on each end together with eight signal leads for attaching to individual test points.

On a mixed-signal bench the P6316 is used to view digital signals on a system bus, working alongside analog probes such as the Tektronix P6139A or P2221 that capture analog waveform information. After the probe output is connected to the oscilloscope and the leads to the circuit, the D15-D0 button sets and displays each digital channel's threshold voltage and vertical position, the signal height applied across all 16 channels, and channel labels, with default thresholds of 1.4 V. The B1 and B2 buttons configure bus characteristics including clock type, bus type (serial or parallel), bus width, and display format in Hex, Binary, or ASCII.

ValueTronics stocks and holds its own inventory in a secure 20,000 square-foot warehouse at 1675 Cambridge Drive in Elgin, Illinois, so customers buy from a company that physically keeps the equipment it sells.

## Accessories Supplied

-   8-Channel leadset, 2 ea (part 196-3508-XX)
-   Micro grabber clip, 2 kits of 10 ea (part 020-2896-XX)
-   Probe tip, 2 kits of 5 ea (part 020-2897-XX)
-   Instructions (English, Japanese, & Simplified Chinese languages), 1 ea (part 071-2345-XX)

## Product Core & Specifications

Characteristic

Description

Electrical and Mechanical Specifications

Input channels

16

Threshold voltage range

±20 V

Threshold accuracy

±100 mV + 3% of threshold setting

Minimum signal swing

500 mV p-p

Maximum signal swing

±20 V centered around the threshold voltage

Maximum nondestructive input signal to probe

±40 V p-p

Input resistance

101 kΩ

Input capacitance

8.0 pF

Minimum detectable input pulse

5 ns

Probe length

0.9 m (3 ft)

Environmental Specifications

Temperature, maximum operating

+50 °C (+122 °F)

Temperature, minimum operating

0 °C (+32 °F)

Temperature, nonoperating

–40 °C to +71 °C (–40 °F to +160 °F)

Humidity

5% to 95% relative humidity at up to +30 °C (+86 °F); 5% to 60% RH above +30 °C (+86 °F) up to +50 °C (+122 °F), non-condensing

Altitude, operating

3 km (9,843 ft) maximum

Altitude, nonoperating

12 km (39,370 ft) maximum

Electrostatic immunity

The probe is not static sensitive

> **Important:** Maximum nondestructive input signal to the probe: ±40 V p-p.

> **Important:** Parallel bus setup information is resident on the MSO Family of oscilloscopes; however, for other buses such as CAN and I2C, you must have the appropriate application key. See your oscilloscope manual or product data sheet for nomenclature and ordering details.

> **Important:** Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement instrument.

> Usage tip: pair the P6316 with Tektronix P6139A or P2221 analog probes to view analog waveform information alongside the digital signals on the bus.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 1130.0 USD
- **Vendor:** Tektronix
- **Type:** Log Prob
- **Tags:** Factory New, Inc., Log Prob, Logic, Manufacturers, Model 6316, Other Equipment, P6316, Probe, product_manual_group_1, Product_new, Tektronix

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 1130.00 USD | In stock |

## Images

- P6316 Tektronix Logic Probe

---

> Source: [ValueTronics](https://valuetronics.com/products/p6316-tektronix-logic-probe-new)
> Updated: 2026-06-02