# Agilent E1412A 6.5-Digit High-Accuracy Multimeter, C-Size (Pre-Owned)

# Agilent E1412A 6.5-Digit High-Accuracy Multimeter, C-Size (Pre-Owned)

## Key Features At A Glance

-   6.5-digit resolution with ±0.0019% DC voltage accuracy for precision measurement applications
-   C-size, 1-slot, message-based VXI module form factor for system integration
-   Comprehensive function set: DCV, ACV, DCI, ACI, 2/4-wire resistance, frequency, and period
-   True RMS AC voltage and current measurements with selectable Slow, Medium, and Fast filters
-   Up to 1000 readings/second into internal memory at 4.5 digits for high-throughput acquisition
-   Fast configuration: 65 range changes/second and 30 function changes/second on DCV
-   Built-in math operations including NULL, MIN/MAX, LIMIT, dB, and dBm
-   DC voltage range from 100 mV to 300 V with 140 dB DC CMRR for noise rejection

The Agilent E1412A is a 6.5-digit high-accuracy multimeter packaged as a C-size, 1-slot, message-based VXI module. It is electrically identical to the E1312A, differing only in mechanical size, and delivers the widest functionality in Agilent's DMM line at price points comparable to 5.5-digit instruments. The module supports a complete set of measurement functions including DC and AC voltage, DC and AC current, 2-wire and 4-wire resistance, frequency, and period.

The E1412A serves automated test system applications requiring high measurement throughput combined with precision. Its capabilities include limit checks that drive a TTL output for pass/fail testing, DC voltage ratio measurements, and on-board math operations such as NULL, MIN/MAX, LIMIT, dB, and dBm. Reading storage with internal memory supports buffered acquisition for high-speed test sequences without backplane bottlenecks during capture.

ValueTronics International operates from a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where every unit in our catalog is stored, inspected, and performance-tested by technicians before shipment. We hold inventory we sell rather than drop-ship from third parties, which means the E1412A you order is the unit our team verified against the datasheet specifications above. Buyers acquiring VXI instrumentation for system integration work need predictable lead times and accurate condition reporting, and our in-house testing process is designed to deliver both.

## Brand Heritage

Agilent Technologies was spun off from Hewlett-Packard in 1999 as the company's test and measurement business. In 2014, Agilent divided again, with the electronic measurement business becoming Keysight Technologies. Agilent-branded T&M instruments such as the E1412A are part of this lineage, and calibration and service for these instruments now routes through Keysight infrastructure.

## Product Core & Specifications

Category

Specification

Value

dc Summary

dc voltage

300 V max.

dc Summary

Voltage accuracy (dc)

± 0.0019%

ac Summary

ac voltage

300 V max.

ac Summary

Voltage accuracy (ac)

± 0.07%

dc Voltage

Measurement method

Continuously integrating, multi-slope III A/D converter

dc Voltage

A/D linearity

0.0002% of reading + 0.0001% of range

dc Voltage

Input resistance (0.1 V, 1 V, 10 V ranges)

Selectable 10 MΩ or 10 GΩ

dc Voltage

Input resistance (100 V, 300 V ranges)

10 MΩ ± 1%

dc Voltage

Input bias current

<30 pA at 25° C

dc Voltage

Input terminals

Copper alloy

dc Voltage

Input protection

300 V on all ranges

Resistance

Measurement method

Selectable 4-wire or 2-wire Ω (Current source referenced to low input)

Resistance

2/4-wire Ω range

100 MΩ

Resistance

Max. lead resistance (4-wire Ω)

10% of range per lead for 100 Ω and 1 kΩ per lead on all other ranges

Resistance

Input protection

300 V on all ranges

dc Current

Shunt resistor

0.1 Ω for 1 A and 3 A, 5 Ω for 10 mA and 100 mA

dc Current

Input protection

Externally accessible 3 A, 250 V fuse

Noise Rejection

dc CMMR (60/50 Hz, 1 kΩ unbalance in LO lead)

140 dB

Noise Rejection

Normal mode rejection (100 PLC / 10 PLC / 1 PLC)

60 dB

Noise Rejection

Normal mode rejection (<1 PLC)

0 dB

System Speed (DC)

Function change

30/s

System Speed (DC)

Range change

65/s

System Speed (DC)

Autorange time

<30 ms

System Speed (DC)

Max. internal trigger rate

1000/s

System Speed (DC)

Max. external trigger rate to memory

1000/s

ac Voltage

Measurement method

ac-coupled True RMS — measures the ac component of the input with up to 300 Vdc of bias on any range (Max ac+dc = 300 V rms)

ac Voltage

Crest factor

Maximum 5:1 at full scale

ac Voltage

ac filter bandwidth (Slow)

3 Hz-300 kHz

ac Voltage

ac filter bandwidth (Medium)

20 Hz-300 kHz

ac Voltage

ac filter bandwidth (Fast)

200 Hz-300 kHz

ac Voltage

Input impedance

1 MΩ ±2%, in parallel with 100 pF

ac Voltage

Input protection

300 Vrms all ranges

ac Current

Measurement method

Direct couple to the fuse and shunt. ac-coupled True RMS measurement (measures the ac component only)

ac Current

Shunt resistor

0.1 Ω for 1 A and 3 A ranges

ac Current

Burden voltage (1A range)

<1 Vrms

ac Current

Burden voltage (3A range)

<2 Vrms

ac Current

Input protection

Externally accessible 3 A, 250 V fuse

Noise Rejection (AC)

ac CMMR (1 kΩ unbalance in LO lead)

70 dB

System Speed (AC)

Function or range change

5/s

System Speed (AC)

Autorange time

<0.8 s

System Speed (AC)

ASCII reading to GPIB

50/sec

System Speed (AC)

Max. internal trigger rate

50/s

System Speed (AC)

Max. external trigger rate to memory

50/s

Frequency/Period

Measurement method

Reciprocal-counting technique. ac-coupled input using the ac voltage measurement function

Frequency/Period

Voltage ranges

100 mV rms full scale to 300 V rms. Auto or manual ranges

Frequency/Period

Gate time

10 ms, 100 ms, or 1 s

Frequency/Period

Max. reading rate

1K

Frequency/Period (System)

Configuration rates

14/s

Frequency/Period (System)

Autorange time

<0.6 s

Frequency/Period (System)

Max. internal trigger rate

80/s

Frequency/Period (System)

Max. external trigger rate to memory

80/s

General

Warmup time

1 hour

General

State storage memory

Power-off state automatically saved

Functions

Idc

3 A

Functions

Iac

3 A

Functions

Frequency

300 kHz

Functions

Period

3.3 µs

Functions

Temp.

Tm, Tc, RTD

VXI Characteristics

VXI device type

Message based

VXI Characteristics

Data transfer bus

A16

VXI Characteristics

Size

C

VXI Characteristics

Slots

1

VXI Characteristics

Connectors

P1/2

Module Current

+5 V (IPM / IDM)

0.2 / 0.1

Module Current

+12 V (IPM / IDM)

0.7 / 0.06

Module Current

\-12 V (IPM / IDM)

0 / 0

**Important:** Maximum input is 300 V on all DCV ranges. Input protection on the DC current function uses an externally accessible 3 A, 250 V fuse.**Important:** The E1412A is a VXI module and requires a compatible VXI mainframe for operation; mainframe is not included.**Important:** Errors will occur when attempting to measure the frequency or period of an input following a dc offset voltage change. The input blocking RC time constant must be allowed to fully settle (up to 1 s) before the most accurate measurements are possible.**Important:** Agilent recommends the use of Teflon or other high impedance, low-dielectric absorption wire insulation for dc measurements.**Important:** All frequency counters are susceptible to error when measuring low-voltage, low-frequency signals. Shielding inputs from external noise pickup is critical for minimizing measurement errors.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Agilent
- **Type:** Multimeter
- **Tags:** Agilent, Agilent Keysight, Manufacturers, Meters & DAQ, Multimeter, product_manual_group_1, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- Agilent E1412A 6.5-Digit High-Accuracy Multimeter, C-Size (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/e1412a-agilent-multimeter-used)
> Updated: 2026-05-30