# Stanford Research Systems SR560 Low-Noise Voltage Preamplifier (Pre-Owned)

# Stanford Research Systems SR560 Low-Noise Voltage Preamplifier (Pre-Owned)

## Key Features At A Glance

-   Low-noise differential front-end: 4 nV/√Hz input noise at 1 kHz with 100 MΩ input impedance
-   Variable gain from 1 to 50,000 in a 1-2-5 sequence, with 0.5% vernier gain adjustment
-   DC to 1 MHz bandwidth; –3 dB at 1.2 MHz typical, ±0.3 dB flatness to 300 kHz (gains up to 1000)
-   Two configurable first-order RC filters: low-pass, high-pass, or band-pass; cutoffs 0.03 Hz to 1 MHz
-   AC- or DC-coupled, differential or single-ended inputs with fully floating BNC connections
-   Line or battery operation — three rechargeable lead-acid batteries provide up to 15 hours
-   RS-232 interface (9600 baud, receive-only) controls up to four units from one computer
-   Dual 600 Ω and 50 Ω outputs drive 10 Vpp; rear-panel ±12 VDC @ 200 mA bias supply

The Stanford Research Systems SR560 is a high-performance, low-noise voltage preamplifier built around a differential front-end. It is designed to recover small voltage signals from the noise floor across a wide range of measurement work, offering selectable gain, configurable signal filtering, and the choice of line or battery operation in a single bench instrument.

The SR560 is suited to a wide range of applications, including low-temperature measurements, optical detection, and audio engineering. Its combination of low input noise, broad gain range, and front-panel signal filtering lets an engineer condition a weak signal before it reaches the downstream instrument in any of these measurement contexts.

ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units leave factory-sealed exactly as received from the manufacturer.

## Product Core & Specifications

Specification

Value

Input

Inputs

AC or DC coupled, single-ended or differential

Input impedance

100 MΩ + 25 pF

Maximum input

3 Vpp

CMRR

100 dB from DC to 1 kHz (100 mV common mode input at 1 kHz, gain of 100, low noise mode. Decreases by 6 dB/octave from 1 kHz to 1 MHz)

Noise

4 nV/√Hz at 1 kHz

Gain

1 to 50,000 in 1-2-5 sequence. Vernier gain in 0.5 % steps

Gain stability

200 ppm/°C

Bandwidth

–3 dB at 1.2 MHz (typ.)

Flatness

±0.3 dB to 300 kHz (gains up to 1000)

Filters

Signal filters

2 configurable (low-pass or high-pass) 6 dB/oct rolloff filters. –3 dB points are settable in a 1-3-10 sequence from 0.03 Hz to 1 MHz.

Gain allocation

High Dynamic Reserve — Gain is increased after the signal filters to prevent overloading. Low Noise — Gain is increased before the filters to improve noise figure.

Output

Maximum output

10 Vpp into 50 Ω and 600 Ω

Filter reset

Long time constant filters may be reset with front-panel button.

DC drift

5 µV/°C referred to input (DC coupled)

Distortion

0.01 % at 1 kHz

Rear panel

±12 VDC @ 200 mA referenced to amplifier ground

General

External gating

TTL input sets gain to zero

Interfaces

RS-232, 9600 baud, receive only

Power

100/120/220/240 VAC, 6 W charged, 30 W while charging. Internal batteries provide 15 hours of operation between charges. Batteries are charged while connected to the line.

Dimensions

8.3" × 3.5" × 13.0" (WHD)

Weight

15 lbs. (batteries installed)

Warranty

One year parts and labor on defects in materials and workmanship

> **Important:** Maximum input: 3 Vpp.

> Usage tip: the SR560 accepts the O560RMS single and O560RMD double rack-mount kits for rack installation, and the O560SB spare battery set (three batteries).

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 3495.0 USD - 4230.0 USD
- **Vendor:** Stanford Research Systems
- **Type:** Pre Amp
- **Tags:** Amplifier, Inc., Manufacturers, Model 560, Other Equipment, Pre-Owned, Preamplifier, product_manual_group_1, Product_used, SR560, SRS, Stanford Research, Stanford Research Systems, Updated Item Review

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 3495.00 USD | In stock |
| NIST Traceable | 3845.00 USD | In stock |
| NIST Traceable with Full Data | 4055.00 USD | In stock |
| ISO IEC 17025 Accredited | 4230.00 USD | In stock |

## Images

- Stanford Research Systems SR560 Low-Noise Voltage Preamplifier (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/sr560-stanford-research-preamplifier-used)
> Updated: 2026-06-03