# Chroma 19032-P 500VA Electrical Safety Analyzer

# Chroma 19032-P 500VA Electrical Safety Analyzer

## Key Features At A Glance

-   Five instruments in one: AC withstand voltage, DC withstand voltage, insulation resistance, ground bond, and leakage current
-   Open/Short Check (OSC) function detects bad contact or DUT short conditions before applying test voltage
-   Twinport simultaneous Hipot and Ground Bond testing cuts production safety-test time approximately in half
-   Flashover detection identifies non-sequential discharge events that leakage current testing alone cannot catch
-   Multi-scan device support enables dynamic leakage current testing across multiple measurement networks
-   Programmable voltage output and limit values with 50 setup memories and 100-group recall
-   Standard RS-232 interface for PC control and Chroma AC source integration; optional GPIB
-   Front panel lockout, password protection, and remote interlock for production-line safety

The Chroma 19032 is an Electrical Safety Analyzer that combines five distinct safety-test instruments — AC withstand voltage (ACWV), DC withstand voltage (DCWV), insulation resistance (IR), ground bond (GB), and leakage current (LC) — in a single chassis. The product is designed for compliance and production safety testing of electrical products where multiple safety parameters must be verified in sequence or in parallel. By consolidating five test functions into one instrument, the 19032 eliminates the bench space, capital cost, and operator time required to maintain separate dedicated testers for each function.

Per the Chroma datasheet, the 19032 series is applied to versatile electrical safety testing including quality assurance sampling inspection, manufacturing line test, and development validation. The datasheet lists specific application categories: power cords, household appliances, information technology products, medical equipment, lab and testing equipment, EMI filters, electric vehicles, and solar/PV inverters. Each of these product categories has a corresponding international safety standard, and the 19032 supports the test sequences these standards require — IEC 60950 for IT products, IEC 60335 for household appliances, IEC 60601 for medical equipment, IEC 60065 for video products, and IEC 61347-1 for lighting and LED.

## Brand Heritage

Chroma ATE Inc. is a Taiwan-headquartered test and measurement manufacturer founded in 1984, with its head office at the Hwaya Technology Park in Taoyuan. Chroma has operated under the same corporate identity since founding and maintains direct subsidiaries in the United States (Chroma Systems Solutions, headquartered in Foothill Ranch, California), Europe (Chroma ATE Europe B.V. in the Netherlands), Japan, and China. The 19032 series is developed and manufactured by Chroma ATE Inc. with no intervening brand changes.

## Compare Other Models in This Series

The 19032 family consists of two models — the base 19032 and the higher-power 19032-P — that share the same five-function architecture (ACWV / DCWV / IR / GB / LC) and the same OSC, Twinport, and Flashover Detection capabilities. The two models differ primarily in output power, ground-bond current range, operator safety circuitry, and host interface.

Both models carry CE certification per the datasheet, use the same LCD display and front-panel layout, and support the same scanner accessory family for dynamic leakage current testing (the 6000-series scanners and the 9030 scanning boxes).

Each model below has its own product page with new-matched pricing. The base 19032 and the 19032-P are sold as separate part numbers; select the model that matches the test power level, ground-bond current range, and operator-safety requirements of your production line.

The 19032 is the base model: 1–30 A AC ground bond current, 40 mA AC / 12 mA DC Hipot cutoff current, RS-232 standard with optional GPIB, and 800 W power consumption at rated load. It is the right choice for general electrical safety testing of IT products, household appliances, power supplies, and adapters where the leakage and ground-bond requirements stay within these ranges.

The 19032-P extends the family with 500 VA Hipot output (versus the base 19032's lower power tier), 100 mA AC / 25 mA DC cutoff current, and 3–40 A AC ground bond current — significantly higher than the base 19032's 30 A maximum. These extensions are needed when the DUT itself draws more leakage current (for example, large EMI filters or large motors as called out on the datasheet) or when the ground-bond standard requires a higher test current.

The 19032-P also adds two operator-safety features that the base 19032 does not include: a GFI (Ground Fault Interrupt) circuit that cuts output voltage if more than approximately 0.5 mA ±0.25 mA flows through the operator path, and a Floating Output mode that keeps ground-terminal leakage below 3 mA on the front output per EN 50191. The 19032-P uses USB (compatible with USB TMC) as its standard interface in place of the base model's RS-232. See the comparison table below for the full specification deltas.

Model

Modes

Max AC Hipot Voltage

Max Ground Bond Current

**19032-P**

ACWV/DCWV/IR/GB/LC

5 kVac / 6 kVdc

40 A AC

19032

ACWV/DCWV/IR/GB/LC

5 kVac / 6 kVdc

30 A AC (40 A or 60 A with optional current transformer)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Parameter

Specification

Mode

Mode

ACWV/DCWV/IR/GB/LC

Withstanding Voltage Test

Output Voltage

DC: 0.05 ~ 6 kV, AC: 0.05 ~ 5 kV

Load Regulation

±(2% of setting + 0.1% of full scale)

Voltage Regulation

2V

Voltage Accuracy

±(2% of setting + 0.1% of full scale)

Cutoff Current

DC: 25 mA, AC: 100 mA

Current Resolution

0.1 µA DC; 1 µA AC

Current Accuracy

±(2% of reading + 0.5% of range)

Output Frequency

50 Hz / 60 Hz

Test Time

0.3 ~ 999 sec, continue

Ramp Time

0.1 ~ 999 sec, Off

Fall Time

0.1 ~ 999 sec, Off

Waveform

Sine wave

Insulation Resistance Test

Output Voltage

DC: 0.05 ~ 1 kV

Voltage Resolution

2V

Voltage Accuracy

±(2% of reading + 0.5% of full scale)

IR Range

0.1 MΩ ~ 50 GΩ

Resistance Resolution

0.1 MΩ

Resistance Accuracy

5% typical

Ground Bond Test

Output Current

AC: 3 ~ 40 A

Current Accuracy

±(2% of setting + 0.1% of full scale)

GR Range

10 mΩ ~ 510 mΩ

Resistance Resolution

0.1 mΩ

Resistance Accuracy

±(1% of reading + 0.1% of full scale)

Test Method

4 wires

Flashover Detection

Setting Mode

Programmable setting

Detection Current

AC: 20 mA, DC: 10 mA

Secure Protection Function

Ground Fault Interrupt

0.5 mA ±0.25 mA AC

Floating Output to ground

< 3 mA, front output only (meets EN50191)

Panel Operation Lock

Present password

Interlock

Yes

GO/NG Judgment Window

Indication, Alarm

GO: Short sound, Green LED / NG: Long sound, Red LED

Data Hold

Least tests data memories

Memory Storage

50 setups with up to 100 groups recall

Interface

Interface

9-pin D-sub I/O control / RS-232 / USB (compatible with USB TMC) / GPIB (Optional)

General

Operation Environment

Temperature: 0°C ~ 40°C, Humidity: 20% ~ 80% RH

Power Consumption

No load: < 100 W; Rated load: 1000 W; Maximum load: 1200 W

Power Requirements

90 ~ 132 Vac or 180 ~ 264 Vac, 47 ~ 63 Hz

Dimensions (H x W x D)

133 x 430 x 500 mm / 5.22 x 16.93 x 19.69 in

Weight

24 kg / 52.86 lbs

Certification

CE

**Important:** Maximum DUT input power capacity for the leakage current scanner options (6000-04 through 6000-08) is AC 300 V at 10 A or 20 A depending on the scanner model, protected by a 20 A / 250 V fuse for DUT short conditions.**Important:** Leakage current scanner options (A190305 through A190350) have differing DUT input power capacities, measurement modes, and supported leakage current types — review the option table to select the correct scanner for the applicable safety standard (IT product, household appliance, lab/TN, medical equipment, special medical / audio & video).**Important:** Ground Bond test current above the analyzer's native range requires the optional Current Transformer accessory (A190334 for 40A or A190337 for 60A); the Current Transformer option is compatible with Model 19032 only.**Important:** GPIB interface is optional and must be ordered separately (A190508 for 19032, A190356 for 19032-P).Recommended pairing: the datasheet specifies Chroma 6400, 6500, 61500, or 61600 series programmable AC sources as the input power supply for dynamic leakage current testing, controlled by the 19032 via its RS-232 interface to maintain stable input voltage during the measurement.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 13980.59 USD - 14155.59 USD
- **Vendor:** Chroma
- **Type:** Hipot
- **Tags:** Chroma, Hipot, Manufacturers, Other Equipment, product_manual_group_1, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 13980.59 USD | In stock |
| NIST Traceable | 14085.59 USD | In stock |
| NIST Traceable with Full Data | 14106.59 USD | In stock |
| ISO IEC 17025 Accredited | 14155.59 USD | In stock |

## Images

- Chroma 19032-P 500VA Electrical Safety Analyzer

---

> Source: [ValueTronics](https://valuetronics.com/products/19032-p-chroma-hipot-new)
> Updated: 2026-05-30