# Rigol SPA-815TGE 1.5 GHz Spectrum Analyzer with Tracking Generator and EMI Filter

# Rigol SPA-815TGE 1.5 GHz Spectrum Analyzer with Tracking Generator and EMI Filter

## Key Features At A Glance

-   Frequency coverage from 9 kHz to 7.5 GHz across the SPA-800 series (SPA-815: 1.5 GHz; SPA-832: 3.2 GHz; SPA-875: 7.5 GHz)
-   All-digital IF technology with 10 Hz minimum resolution bandwidth for distinguishing closely spaced signals
-   Displayed Average Noise Level to -161 dBm (typ.) with preamplifier on, normalized to 1 Hz
-   Phase noise <-98 dBc/Hz @ 10 kHz offset (SPA-832/875); <-80 dBc/Hz (SPA-815)
-   Level measurement uncertainty <0.8 dB (SPA-832/875); <1.5 dB (SPA-815)
-   Tracking generator included on all models (100 kHz to instrument's frequency range)
-   LAN (LXI core 2011), USB Host & Device, and optional GPIB connectivity for automated test integration
-   8-inch WVGA (800x480) TFT LCD display with EMI filter and quasi-peak detector kit included

The Rigol SPA-800 Series is a family of digital IF spectrum analyzers spanning 9 kHz to 7.5 GHz, available in three frequency tiers: the SPA-815 (to 1.5 GHz), SPA-832 (to 3.2 GHz), and SPA-875 (to 7.5 GHz). All three models share the same all-digital IF architecture, 8-inch WVGA display, and a compact benchtop form factor measuring 361.6 mm x 178.8 mm x 128 mm.

A spectrum analyzer shows signal energy distributed across a range of frequencies — the frequency-domain view of what signals are present, at what frequency, and at what power level. The SPA-800 Series is designed for RF design and characterization, EMC pre-compliance testing (EMI filter and quasi-peak detector kit included), and educational applications. The included tracking generator extends utility into scalar component characterization — filter passband measurement, amplifier gain flatness, and cable insertion loss.

## Brand Heritage

Rigol Technologies is a Chinese test and measurement manufacturer that has expanded its presence in the global professional T&M market over the past two decades. Rigol maintains its own brand and product development; the SPA-800 Series is distributed through authorized partners including Com-Power Corporation.

## Compare Other Models in This Series

The SPA-800 Series consists of three models that share an identical all-digital IF architecture, display, and feature set — differing primarily in maximum frequency coverage and certain RF performance specifications. The SPA-815 covers 9 kHz to 1.5 GHz, the SPA-832 extends to 3.2 GHz, and the SPA-875 reaches 7.5 GHz. All three include a tracking generator covering the instrument's frequency range, EMI filter and quasi-peak detector kit for pre-compliance work, and 8-inch WVGA display.

Beyond frequency range, the SPA-832 and SPA-875 share improved RF specifications relative to the SPA-815 — including lower phase noise (<-98 dBc/Hz vs. <-80 dBc/Hz at 10 kHz offset), tighter level measurement uncertainty (<0.8 dB vs. <1.5 dB nominal), and a 10 Hz minimum resolution bandwidth (versus 100 Hz on the SPA-815). Preamplifier coverage is standard on the SPA-815 (20 dB nominal) and available as an option on the SPA-832 (PA-DSA832) and SPA-875 (PA-DSA875) at 17 dB nominal.

Each new SPA-800 model linked below is its own dedicated product page with condition-matched pricing, current inventory status, and accessory configuration details. Confirm the specific model that matches your frequency coverage requirement and any required options before issuing a purchase order.

The SPA-875 is the top-tier model in the SPA-800 family, covering 9 kHz to 7.5 GHz. It shares the improved RF specifications of the SPA-832 (10 Hz minimum RBW, <-98 dBc/Hz phase noise at 10 kHz offset, <0.8 dB level measurement uncertainty) while extending coverage through the 3.2 GHz to 7.5 GHz range — relevant for applications addressing the upper WiFi bands, ISM bands, and lower microwave work.

The model decision is primarily driven by maximum frequency requirement. For applications below 1.5 GHz where premium phase noise is not required, the SPA-815 offers integrated 20 dB preamplifier as standard. For applications requiring 10 Hz minimum RBW, improved phase noise, and tighter level uncertainty — but only sub-3.2 GHz coverage — the SPA-832 is appropriate. For applications requiring coverage above 3.2 GHz (WiFi 5 GHz band, ISM bands above 3 GHz, lower microwave), the SPA-875 is required.

The optional preamplifier (PA-DSA832 or PA-DSA875) improves DANL by approximately 20–25 dB relative to PA-off operation and is a meaningful investment for applications measuring low-level signals near the instrument's noise floor. Reference the comparison table that follows for the specific frequency, RBW, phase noise, and DANL specifications by model.

Model

Frequency Range

Phase Noise @ 10 kHz Offset

Min RBW

**SPA-815TGE**

9 kHz to 1.5 GHz

<-80 dBc/Hz

100 Hz

SPA-832TGE

9 kHz to 3.2 GHz

<-98 dBc/Hz

10 Hz

SPA-875TGE

9 kHz to 7.5 GHz

<-98 dBc/Hz

10 Hz

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   Quick guide (hard copy) - QGD07X00
-   CDROM (user's guide, programming guide)
-   Power cable

## Product Core & Specifications

Category

Specification

SPA-815

SPA-832

SPA-875

Frequency

Frequency

Frequency range

9 kHz to 1.5 GHz

9 kHz to 3.2 GHz

9 kHz to 7.5 GHz

Frequency

Frequency resolution

1 Hz

Internal Reference

Reference frequency

10 MHz

Internal Reference

Initial calibration accuracy

<1 ppm

Internal Reference

Temperature stability (0°C to 50°C, ref to 25°C)

< 2 ppm

< 0.5 ppm

Internal Reference

Aging rate

< 2 ppm/year

< 1 ppm/year

Frequency Counter

Resolution

1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz

Frequency Span

Range

0 Hz, 100 Hz to maximum frequency of instrument

SSB Phase Noise

10 kHz offset (fc = 1 GHz)

<-80 dBc/Hz

<-98 dBc/Hz

SSB Phase Noise

100 kHz offset (fc = 1 GHz)

<-100 dBc/Hz (typ.)

<-100 dBc/Hz (typ.)

Residual FM

RBW = VBW = 1 kHz

< 50 Hz (nom.)

< 20 Hz (nom.)

Bandwidths

Bandwidths

Resolution bandwidth (-3 dB)

100 Hz to 1 MHz, in 1-3-10 sequence

10 Hz to 1 MHz, in 1-3-10 sequence

Bandwidths

RBW uncertainty

<5% (nom.)

Bandwidths

Resolution filter shape factor (60dB:3dB)

<5 (nom.)

Bandwidths

Video bandwidth (-3 dB)

1 Hz to 3 MHz, in 1-3-10 sequence

Bandwidths

Resolution bandwidth (-6 dB) EMI

200 Hz, 9 kHz, 120 kHz

Amplitude

Measurement Range

Range (fc ≥ 10 MHz)

DANL to +20 dBm

Max Input Level

DC voltage

50 V

Max Input Level

CW RF power (attenuation = 30 dB)

+20 dBm (100 mW)

Max Input Level

Max damage level

+30 dBm (1 W)

Level Display

Logarithmic level axis

1 dB to 200 dB

Level Display

Linear level axis

0 to Reference Level

Level Display

Number of display points

601

Level Display

Number of traces

3 + Math Trace

Level Display

Trace detectors

normal, positive-peak, negative-peak, sample, RMS, voltage average, quasi-peak (with EMI-DSA800 option)

Level Display

Trace functions

clear write, max hold, min hold, average, view, blank

Level Display

Units of level axis

dBm, dBmV, dBµV, nV, µV, mV, V, nW, µW, mW, W

Input Attenuation

Setting range

0 to 30 dB, in 1 dB step

Input Attenuation

Switching uncertainty (fc=50 MHz, relative to 10 dB, 20°C to 30°C)

< 0.5 dB

< 0.3 dB

Absolute Amplitude Uncertainty

fc = 50 MHz, peak detector, PA off, attenuation = 10 dB, input = -10 dBm, 20°C to 30°C

<0.4 dB

<0.3 dB

RBW Switching Uncertainty

relative to 1 kHz RBW

<0.1 dB

Reference Level

Range

\-100 dBm to +20 dBm, in 1 dB step

Reference Level

Resolution (log Scale / linear Scale)

0.01 dB / 4 digits

Preamplifier

Gain 100 kHz to 1.5 GHz

20 dB (nom.) standard

17 dB (nom.) option

17 dB (nom.) option

Preamplifier

Gain 1.5 GHz to 3.2 GHz

—

17 dB (nom.) option

17 dB (nom.) option

Preamplifier

Gain 3.2 GHz to 7.5 GHz

—

—

17 dB (nom.) option

Level Measurement Uncertainty

95% confidence, S/N > 20 dB, RBW = VBW = 1 kHz, PA off, atten = 10 dB, -50 dBm < input ≤ 0 dBm, fc > 10 MHz, 20°C to 30°C

<1.5 dB (nom.)

<0.8 dB (nom.)

RF Input VSWR

300 kHz to 1.5 GHz (attenuation ≥ 10 dB)

<1.5 (nom.)

RF Input VSWR

1.5 GHz to 3.2 GHz

—

<1.5 (nom.)

<1.5 (nom.)

RF Input VSWR

3.2 GHz to 7.5 GHz

—

—

<1.8 (nom.)

Distortion

Second Harmonic Intercept (SHI)

fc ≥ 50 MHz, input = -20 dBm, atten = 10 dB

+40 dBm

+45 dBm

Third-order Intercept (TOI)

fc ≥ 50 MHz, two -20 dBm tones at input mixer spaced by 200 kHz, atten = 10 dB

+10 dBm

+11 dBm, +15 dBm (typ.)

**Important:** Maximum safe input: +20 dBm CW RF power with 30 dB attenuation; maximum damage level +30 dBm (1 W); maximum DC voltage 50 V. When fc ≥ 10 MHz, input level >+25 dBm with preamplifier off engages the protection switch.**Important:** Note (Max damage level): When fc ≥ 10 MHz, input level > +25 dBm and PA is Off, the protection switch will be on.**Important:** All charts in this manual are the measurement results of multiple instruments at room temperature unless otherwise noted. The specifications (except the TG specifications) listed in this manual are those when the tracking generator is off.**Important:** USB Disk is not supplied with the instrument; user-provided storage required for external mass memory.**Important:** The preamplifier is standard on the SPA-815 and is an option (PA-DSA832, PA-DSA875) on the SPA-832 and SPA-875 models.Recommended pairing: use the included tracking generator (output 100 kHz to instrument frequency range) with the optional VSWR Bridge (VB1020/VB1040/VB1080) for return loss and VSWR characterization of RF components.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 2250.0 USD
- **Vendor:** Rigol
- **Type:** Spec An
- **Tags:** Analyzers, Com-Power, Manufacturers, product_manual_group_1, Product_new, Spectrum

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 2250.00 USD | In stock |

## Images

- Rigol SPA-815TGE 1.5 GHz Spectrum Analyzer with Tracking Generator and EMI Filter

---

> Source: [ValueTronics](https://valuetronics.com/products/spa-815tge-com-power-spectrum-analyzer-new)
> Updated: 2026-05-30
