# Agilent E5062A 3 GHz ENA-L RF Network Analyzer (Pre-Owned)

# Agilent E5062A 3 GHz ENA-L RF Network Analyzer (Pre-Owned)

## Key Features At A Glance

-   Frequency coverage from 300 kHz to 3 GHz across the two-model ENA-L series
-   Type-N test ports available in 50 Ω or 75 Ω configurations
-   Up to 4 independent measurement channels with 4 data and 4 memory traces each
-   10.4-inch TFT color LCD (VGA); hardkey, optional touch screen, or mouse control
-   GPIB (IEEE-488), 10/100BaseT LAN, USB, and Handler I/O; LXI Class C compliant
-   System dynamic range up to 120 dB at 10 Hz IF bandwidth (1 MHz to 3 GHz)
-   Calibration types include response, one-port, enhanced response, and optional full 2-port

The Agilent ENA-L RF Network Analyzers comprise two models — the E5061A, covering 300 kHz to 1.5 GHz, and the E5062A, covering 300 kHz to 3 GHz. Both are vector network analyzers built on a common platform that employs a graphical user interface based on the Windows operating system, operable through a hardkey interface, an optional touch screen, or a mouse. Each analyzer provides up to four independent measurement channels, each with its own display window and up to four data traces and four memory traces.

A network analyzer characterizes how a device or network reflects and transmits signals across frequency. The ENA-L measures S-parameters — S11 and S21 in the transmission/reflection configuration, and the full S11, S21, S12, and S22 set with the full 2-port option — and converts those parameters into reflection and transmission impedance, reflection and transmission admittance, and 1/S. Available data formats include log and linear magnitude, phase, expanded phase, positive phase, group delay, SWR, real, imaginary, Smith chart, and polar. Fault-location transformation to the distance and time domains is available as an option, alongside limit-line definition for pass/fail testing.

ValueTronics stocks and holds its own test-and-measurement inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, and every pre-owned unit is fulfilled directly from that facility. Used units are inspected and functionally verified in-house before they ship, while new units ship factory-sealed exactly as received from the manufacturer.

## Brand Heritage

The ENA-L line carries Agilent Technologies branding. Agilent was established in 1999 as a spin-off of Hewlett-Packard, and its electronic test-and-measurement business was subsequently established as Keysight Technologies in 2014.

## Compare Other Models in This Series

The ENA-L family is offered as two models sharing a common platform: the E5061A and the E5062A. Both provide the same measurement architecture — up to four channels, Type-N 50 Ω or 75 Ω test ports, the same selectable calibration types, and the same Windows-based interface — and differ primarily in their upper frequency limit.

The E5061A covers 300 kHz to 1.5 GHz, while the E5062A extends coverage to 3 GHz. Measurement-parameter scope (S11/S21 versus the full 2-port S11/S21/S12/S22 set) and capabilities such as fault location, extended power range, and touch screen are selected by option code rather than by base model.

Each model below is its own dedicated product page with pre-owned-matched pricing. Select the model whose frequency range and option configuration matches your measurement requirement, then open the listing for the condition you need.

The principal difference between the two models is frequency span: the E5061A reaches 1.5 GHz and the E5062A reaches 3 GHz, as shown in the comparison table. Test port output frequency range follows the model accordingly — 300 kHz to 1.5 GHz for the E5061A and 300 kHz to 3 GHz for the E5062A.

Beyond frequency range, the two models share corrected-performance specifications, connector options, calibration types, channel count, and interfaces. Measurement-parameter scope and features such as fault location, extended power range, and touch screen are determined by option codes that apply across both models.

Model

Frequency Range

Max Output Power

Connector Type

**E5062A**

300 kHz to 3 GHz

10 dBm

Type-N, 50 Ω or 75 Ω

E5061A

300 kHz to 1.5 GHz

10 dBm

Type-N, 50 Ω or 75 Ω

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Specification

Value

System Dynamic Range (no averaging, 23 °C ±5 °C; applies to units with serial prefix MY442 and above)

300 kHz to 1 MHz, IF bandwidth = 3 kHz

90 dB

1 MHz to 3 GHz, IF bandwidth = 3 kHz

95 dB

300 kHz to 1 MHz, IF bandwidth = 10 Hz

115 dB

1 MHz to 3 GHz, IF bandwidth = 10 Hz

120 dB (130 dB typical)

Corrected System Performance — Type-N 50 Ω, 85032F cal kit, Full 2-Port (IF BW = 10 Hz, 23 °C ±5 °C); values shown as 300 kHz–1.5 GHz / 1.5–3 GHz

Directivity

49 dB / 46 dB

Source match

41 dB / 40 dB

Load match

49 dB / 46 dB

Reflection tracking

±0.011 dB / ±0.021 dB

Transmission tracking

±0.015 dB / ±0.018 dB

Corrected System Performance — Type-N 50 Ω, 85032F cal kit, Enhanced Response; 300 kHz–1.5 GHz / 1.5–3 GHz

Directivity

49 dB / 46 dB

Source match

41 dB / 40 dB

Load match

15 dB / 15 dB

Reflection tracking

±0.011 dB / ±0.021 dB

Transmission tracking

±0.015 dB / ±0.018 dB

Corrected System Performance — Type-N 75 Ω, 85036E cal kit, Full 2-Port; 300 kHz–1.5 GHz / 1.5–3 GHz

Directivity

48 dB / 44 dB

Source match

41 dB / 35 dB

Load match

48 dB / 44 dB

Reflection tracking

±0.010 dB / ±0.019 dB

Transmission tracking

±0.015 dB / ±0.029 dB

Corrected System Performance — Type-N 75 Ω, 85036E cal kit, Enhanced Response; 300 kHz–1.5 GHz / 1.5–3 GHz

Directivity

48 dB / 44 dB

Source match

41 dB / 35 dB

Load match

15 dB / 15 dB

Reflection tracking

±0.010 dB / ±0.019 dB

Transmission tracking

±0.015 dB / ±0.029 dB

Uncorrected System Performance (correction off, 23 °C ±5 °C, 300 kHz to 3 GHz)

Directivity

25 dB

Source match

25 dB

Load match

15 dB

Transmission tracking

±1.0 dB

Reflection tracking

±1.0 dB

Test Port Output Frequency

Range (E5061A)

300 kHz to 1.5 GHz

Range (E5062A)

300 kHz to 3 GHz

Resolution

1 Hz

Source stability

±5 ppm (5 °C to 40 °C)

CW accuracy

±5 ppm, 23 °C ±5 °C

Test Port Output Power (300 kHz to 3 GHz)

Level accuracy (23 °C ±5 °C)

±0.8 dB (at 0 dBm, 50 MHz absolute); ±1.0 dB (at 0 dBm, relative to 50 MHz reference)

Level linearity (23 °C ±5 °C)

±0.75 dB (at –5 to 10 dBm)

Range (standard)

–5 to 10 dBm

Range (extended power)

–45 to 10 dBm (non-harmonic spurious may limit power range)

Sweep range (without extended power range)

–5 to 10 dBm

Level resolution

0.05 dB

Test Port Output Signal Purity

Harmonics (2nd or 3rd), 10 MHz to 2 GHz

< –25 dBc (at 5 dBm)

Non-harmonic spurious, 10 MHz to 3 GHz

< –30 dBc (at 5 dBm)

Test Port Input Levels (300 kHz to 3 GHz)

Maximum test port input level

+10 dBm

Damage level

+20 dBm, ±30 VDC

Crosstalk

–110 dB

Test Port Input — Trace Noise (IF BW = 3 kHz, source power +10 dBm, 23 °C ±5 °C)

Trace noise magnitude, 300 kHz to 1 MHz

8 mdB rms

Trace noise magnitude, 1 MHz to 3 GHz

5 mdB rms

Trace noise phase, 300 kHz to 1 MHz

0.05° rms

Trace noise phase, 1 MHz to 3 GHz

0.03° rms

Test Port Input — Stability (23 °C ±5 °C)

Stability magnitude, 3 MHz to 3 GHz

0.01 dB/°C

Stability phase, 3 MHz to 3 GHz

0.1°/°C

System Bandwidths

IF bandwidth range

10 Hz to 30 kHz

Nominal IF bandwidth settings

10, 30, 100, 300, 1 k, 3 k, 10 k, 30 k

Front Panel Information

RF connectors

Type-N, female; 50 Ω or 75 Ω

Display size

10.4 in TFT color LCD

Display resolution

VGA (640 x 480)

Rear Panel Information

External trigger connector

BNC, female; LOW threshold 0.5 V / HIGH threshold 2.1 V; input range 0 to +5 V; pulse width ≥ 2 µsec; negative (downward) polarity only

External reference signal input

BNC, female; 10 MHz ±10 ppm; 0 dBm ±3 dB

Internal reference signal output

BNC, female; 10 MHz ±10 ppm; sine wave; 0 dBm ±3 dB into 50 Ω; output impedance 50 Ω

VGA video output

15-pin mini D-Sub, female; drives VGA compatible monitors

GPIB

24-pin D-Sub (type D-24), female; compatible with IEEE-488

Parallel port

36-pin D-Sub (type 1284-C), female

USB port

Type A, female (Vcc 4.75 to 5.25 VDC, 500 mA maximum)

LAN

10/100 BaseT Ethernet, 8-pin; auto selects data rate

Handler I/O port

36-pin Centronics, female

Line Power (a third-wire ground is required)

Frequency

47 Hz to 63 Hz

Voltage

90 to 132 VAC, or 198 to 264 VAC (automatically switched)

> **Important:** Maximum test port input level: +10 dBm. Damage level: +20 dBm, ±30 VDC.

> **Important:** A third-wire ground is required for the line power connection.

> **Important:** Level accuracy for 75 Ω analyzers is not a specification for frequencies > 2 GHz; it is a typical characteristic.

> **Important:** System dynamic range specifications apply only to units with serial prefix MY442 and above.

> **Important:** LXI Class C compliance applies only to units shipped with firmware revision A.03.00 or later.

> **Important:** Corrected system performance is achieved using an external calibration kit (85032F for 50 Ω Type-N, 85036E for 75 Ω Type-N); the calibration kit is a separate product and is required to perform full 2-port or enhanced response calibration.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included.
-   Functional verification included.
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Agilent
- **Type:** Net Ana
- **Tags:** Agilent, Agilent Keysight, Agilent Technologies, Analyzers, E5062, E5062A, Inc., Keysight, Manufacturers, Model 5062, Network, Network Analyzer, Pre-Owned, product_manual_group_1, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- Agilent E5062A 3 GHz ENA-L RF Network Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/e5062a-agilent-network-analyzer-used)
> Updated: 2026-06-02