# Agilent 8510C 45 MHz to 110 GHz Vector Network Analyzer (Pre-Owned)

# Agilent 8510C 45 MHz to 110 GHz Vector Network Analyzer (Pre-Owned)

## Key Features At A Glance

-   Vector network analyzer covering 45 MHz to 110 GHz depending on test set and source configuration
-   Measures magnitude, phase, and group delay of two-port networks (S11, S21, S12, S22)
-   Dual display channels with four-quadrant or overlay formats and five independent data markers per trace
-   Optional time domain analysis (Option 010) with low pass step, low pass impulse, and bandpass impulse stimulus modes
-   Multiple calibration techniques supported: full two-port, TRL, LRM, one-port, response/isolation, and adapter removal
-   Selectable 51, 101, 201, 401, or 801 measurement points per sweep, plus frequency list mode (1 to 792 points across up to 30 segments)
-   GPIB system bus controls compatible synthesized sources, S-parameter test sets, plotters, and printers
-   Built-in 3.5-inch disk drive supporting LIF and MS-DOS formats for instrument states, calibration sets, and trace data

The Agilent 8510C is a vector network analyzer that measures the magnitude, phase, and group delay of two-port networks to characterize their linear behavior. It serves as the signal-processing display unit of a modular system in which the user selects the RF source, S-parameter test set, and calibration accessories to match the measurement application. Broadband coverage extends from 45 MHz to 50 GHz in 2.4 mm coax, from 45 MHz to 110 GHz in 1.0 mm coax, and from 33 GHz to 110 GHz in standard waveguide bands.

Per the datasheet, the 8510C is used for full S-parameter measurement of two-port RF and microwave networks, with optional time domain analysis (Option 010) for displaying a network's response to an impulse or step waveform via inverse Fourier transform. The instrument supports pulse-profile measurements (Option 008), power-domain sweeps at a CW frequency for amplifier 1 dB gain compression characterization, and auxiliary-voltage domain measurements using the rear-panel ±10 V analog output as device stimulus. Configurations documented in the datasheet address coaxial network measurement, millimeter-wave waveguide measurement, pulsed-RF testing, and materials measurement when paired with the 85071B software or 85070B dielectric probe kit.

## Brand Heritage

Hewlett-Packard's test and measurement business was spun out as Agilent Technologies in 1999; the electronic measurement portion of Agilent was subsequently transferred to Keysight Technologies in 2014. Instruments such as the 8510C originated under the HP and Agilent banners and are referenced under both names in the installed base and service documentation.

## Product Core & Specifications

Parameter

Specification

Frequency Range

45 MHz to 110 GHz (system configuration dependent)

Number of Display Channels

Two

Measurement Parameters

S11, S21, S12, S22; user-redefinable; conversion to Z1, Z2, Y1, Y2, and 1/S

Domains Available

Frequency, Time (Option 010), Pulse Profile (Option 008), Auxiliary Voltage (±10 VDC), Power

Cartesian Formats

Log/linear magnitude, phase, group delay, SWR, real, imaginary

Smith Chart Marker Format

Log magnitude, linear magnitude, R + jX, G + jB

Polar Marker Format

Log magnitude, linear magnitude, phase, real and imaginary

Data Markers

Five independent

Measured # Points per Sweep

51, 101, 201, 401, 801 points; frequency list mode: 1 to 792

Sweep Modes

Ramp sweep (analog), Stepped sweep, Frequency list, Single point, Fast CW (GPIB only)

Sweep Time

0.1 to 100 seconds (user-entered); minimum auto-selected

Data Averaging

1 to 4096 in powers of 2

Trace Smoothing

0.125% to 20% of trace width

Display Type

Color (raster scan), 7.5" diagonal; graticule 5.5" diagonal

Limit Lines

Up to eight test limit segments per parameter per channel

Internal Disk Drive

3.5 inch; HP LIF or MS-DOS format

Instrument State Storage

8 non-volatile registers

Calibration Sets

8 separate; storage may be limited if 801-point full two-port

Remote Interface

GPIB (IEEE 488-1978, IEC 625, IEEE 728-1982); RS-232-C

Rear Panel: Sweep In

0 to 10 V input

Rear Panel: 10 MHz In

Input level –10 dBm to +20 dBm typical; ±0.005% (50 ppm) frequency accuracy

Rear Panel: 20 MHz Out

±0.01% frequency accuracy typical

Rear Panel: Analog ±10V

Range –9.995 to +10.000 V; linearity ±0.1% typical; resolution 4.88 mV; 1kΩ output impedance

External Trigger

TTL; pulse repetition period 1 ms min (no averaging); pulse width 1 µs min

Operating Temperature

5 °C to 40 °C

Non-Operating Temperature

–40 °C to +75 °C

Line Frequency

47.5 to 66 Hz

Line Voltage

100, 120, 200, 240 Vac, ±10%

Power Consumption (8510C)

460 VA maximum

Net Weight

42 kg (92 lb)

Shipping Weight

52 kg (114 lb)

Dimensions (W x H x D)

42.4 cm (16.7 in) W x 33.8 cm (13.3 in) H x 50.8 cm (20 in) D (approx, plus 10 cm rear clearance)

**Important:** The 8510C requires a compatible RF source, S-parameter test set, and calibration kit to function as a complete network analyzer system. Ramp sweep mode is not available on 8510XF systems, and the 8340, 8341, and 8350 series sources are not compatible with 8510XF configurations.**Important:** Discontinued Product: Information herein may refer to products/services no longer supported by Agilent. This datasheet is provided for support reference only.**Important:** The 8510C network analyzer is the central display/processor; a complete measurement system requires the additional purchase of an RF source (e.g., 8360 series synthesized sweeper), an S-parameter test set (e.g., 8514B, 8515A, 8517B), and an appropriate calibration kit. None of these are included with the 8510C base unit.**Important:** Test port cables and test port adapter sets are sold separately and are required to connect a device under test to the test set's special rugged test port.**Important:** Specifications describe warranted performance over the temperature range of 23 °C ± 3 °C. Calibration must be performed within the calibration kit's operating temperature (23 °C ± 3 °C). For a calibration to remain fully verifiable, the network analyzer temperature must remain within ±1 °C of the initial measurement calibration temperature.**Important:** Ramp sweep mode is not available in the 8510XF systems.**Important:** Pulse profile domain (Option 008) is not available in the 8510XF systems.**Important:** The 8340, 8341 and 8350 series sources are not compatible with the 8510XF systems.**Important:** Power domain requires 8360 series sources; sources with firmware revisions prior to 01 Oct 93 require updating.Recommended pairing: combine the 8510C with a compatible S-parameter test set (8514B, 8515A, 8517B, 85110A, 85110L, or 85104A series), a supported synthesized source (8360 series, 8340A/B, 8341A/B, or 8350B with 835xx plug-in for ramp sweep), and a calibration kit matched to the connector type and frequency range of the device under test.

## About this used unit

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD - 630.0 USD
- **Vendor:** Agilent
- **Type:** Network Analyzer
- **Tags:** Agilent, Agilent Keysight, Analyzers, Manufacturers, Network, product_manual_group_1, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 350.00 USD | In stock |
| NIST Traceable with Full Data | 490.00 USD | In stock |
| ISO IEC 17025 Accredited | 630.00 USD | In stock |

## Images

- Agilent 8510C 45 MHz to 110 GHz Vector Network Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/8510c-agilent-network-analyzer-used)
> Updated: 2026-05-30
