# Tektronix MSO2014 100 MHz Mixed Signal Oscilloscope (Pre-Owned)

# Tektronix MSO2014 100 MHz Mixed Signal Oscilloscope (Pre-Owned)

## Key Features At A Glance

-   Bandwidth from 100 MHz to 200 MHz across the series, with 2 or 4 analog channels per model
-   1 GS/s maximum sample rate on all channels
-   1 Mega sample (1 M point) record length on all channels
-   5,000 wfm/s maximum waveform capture rate with real-time intensity grading
-   16 integrated digital channels on MSO2000 models for mixed-signal analysis (2+16 or 4+16 configurations)
-   FilterVu variable low-pass filter removes noise while still capturing glitches as narrow as 5 ns
-   Wave Inspector navigation and search for efficient long-record-length analysis
-   USB 2.0 host and device ports standard; optional LAN, GPIB, and Video-Out adapters

The Tektronix MSO2000 and DPO2000 Series are digital phosphor oscilloscopes (DPOs) built to visualize signals and find answers quickly. The DPO2000 Series provides 1 M points of usable record length on all channels, serial trigger and decode analysis options, and a variable low-pass filter, all in a compact form factor. The MSO2000 Series adds 16 integrated digital channels, allowing analog and digital signals to be visualized and time-correlated on a single instrument and extending triggering functionality across all 20 channels for debugging mixed analog and digital designs.

These oscilloscopes are applied to embedded design and debug, mixed signal design and debug, power measurements, automotive electronics, education and training, and video design and debug. Serial data analysis in embedded system design is among the most common applications that call for the series' long record length, as more embedded systems replace wide parallel buses with serial buses such as I2C, SPI, RS-232/422/485/UART, CAN, and LIN.

ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where the company has specialized in test and measurement equipment since 1992. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer — so buyers get a condition-appropriate instrument backed by people who know the equipment.

## Brand Heritage

Tektronix, founded in 1946, was acquired by Danaher Corporation in 2007 and became part of Fortive Corporation when Fortive was spun off from Danaher in 2016. The Tektronix brand has continued under its own name throughout these corporate transitions.

## Compare Other Models in This Series

The MSO2000 and DPO2000 Series group six digital phosphor oscilloscopes into one family that shares a common platform: 1 GS/s sample rate, 1 M point record length on all channels, a 5,000 wfm/s waveform capture rate, Wave Inspector navigation and search, and the FilterVu variable low-pass filter. The DPO2000 models are digital phosphor oscilloscopes, while the MSO2000 models add 16 integrated digital channels for mixed-signal design and analysis.

Across the series, models differ in analog bandwidth and analog channel count, and the MSO variants extend triggering and analysis across as many as 20 time-correlated channels. Because the platform is shared, a measurement workflow learned on one model transfers directly to the others in the family.

Each model linked below is its own dedicated product page with condition-matched pricing for the pre-owned configuration you select. Compare bandwidth, analog channel count, and the mixed-signal option across the family, then choose the specific model and condition that fit your application.

The family splits along two axes. Analog bandwidth steps from 100 MHz on the MSO2012, MSO2014, DPO2012, and DPO2014 to 200 MHz on the MSO2024 and DPO2024. Analog channel count is 2 on the MSO2012 and DPO2012 and 4 on the MSO2014, MSO2024, DPO2014, and DPO2024.

The MSO designation adds 16 digital channels along with parallel bus trigger and analysis, which the DPO models do not include; all six models share the 1 GS/s sample rate and 1 M point record length. Refer to the comparison table below for the per-model bandwidth, channel-count, and calculated rise-time figures.

Model

Bandwidth

Analog Channels

Digital Channels

**MSO2014**

100 MHz

4

16

MSO2012

100 MHz

2

16

MSO2024

200 MHz

4

16

DPO2012

100 MHz

2

0

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   One P2221 200 MHz, 1x/10x Passive Probe per Analog Channel
-   User Manual and Translated Front-Panel Overlay
-   Documentation CD (063-4118-xx)
-   OpenChoice Desktop Software
-   NI LabVIEW SignalExpress Tektronix Edition LE Software
-   Calibration certificates document measurement traceability to National Metrology Institute(s) and ISO9001 Quality System Registration
-   Power Cord
-   Three-year warranty
-   One P6316 16-channel logic probe and accessory kit
-   Accessory bag (016-2008-xx)

## Product Core & Specifications

Specification

Value

Horizontal System - Analog Channels

Maximum Sample Rate (all channels)

1 GS/s

Minimum Peak Detect Pulse Width

7.0 ns

Maximum Record Length (all channels)

1 M points

Maximum Duration of Time Captured at Highest Sample Rate (all channels)

1 ms

Timebase Range

4 ns to 100 s

Timebase Delay Time Range

\-10 div to 5000 s

Channel-to-Channel Deskew Range

± 100 ns

Timebase Accuracy

± 25 ppm

Horizontal System - Digital Channels

Maximum Sample Rate (when using any of channels D7-D0)

1 GS/s (1 ns resolution)

Maximum Sample Rate (when using any of channels D15-D8)

500 MS/s (2 ns resolution)

Maximum Record Length

1 M points

Minimum Detectable Pulse Width

5 ns

Channel-to-Channel Skew

2 ns typical

Vertical System - Analog Channels

Input Channels

4

Analog Bandwidth (-3 dB)

100 MHz

Calculated Rise Time

3.5 ns

Hardware Bandwidth Limits

20 MHz

Input Coupling

AC, DC, GND

Input Impedance

1 MΩ ± 2%, 11.5 pF ± 2 pF

Input Sensitivity Range

2 mV/div to 5 V/div

Vertical Resolution

8 bits

Max Input Voltage

300 VRMS with peaks ≤450 V

DC Gain Accuracy (with offset set to 0 V)

± 3% for 10 mV/div to 5 V/div, ± 4% for 2 mV/div to 5 mV/div

Offset Range (2 mV/div to 200 mV/div)

± 1 V

Offset Range (>200 mV/div to 5 V/div)

± 25 V

Channel-to-Channel Isolation (Any Two Channels at Equal Vertical Scale)

≥100:1 at ≤100 MHz

Bandwidth at 2 mV/div (all models)

20 MHz

Vertical System - Digital Channels

Input Channels

16 Digital (D15 to D0)

Thresholds

Threshold per set of 8 channels

Threshold Selections

TTL, CMOS, ECL, PECL, User Defined

User Defined Threshold Range

± 20 V

Maximum Input Voltage

± 40 V

Threshold Accuracy

± (100 mV + 3% of threshold setting)

Maximum Input Dynamic Range

80 Vpk-pk (threshold setting dependent)

Minimum Voltage Swing

500 mVpk-pk

Input Impedance

101 kΩ

Probe Loading

8 pF

Vertical Resolution

1 bit

Acquisition Modes

Sample

Acquires sampled values.

Peak Detect

Captures glitches as narrow as 3.5 ns at all sweep speeds.

Averaging

From 2 to 512 waveforms included in average.

Roll

Scrolls waveforms right to left across screen at sweep speeds slower than or equal to 40 ms/div.

Trigger System

Main Trigger Modes

Auto, Normal and Single.

Trigger Coupling

DC, HF reject (attenuates > 85 kHz), LF reject (attenuates < 65 kHz), noise reject (reduces sensitivity).

Trigger Holdoff Range

20 ns to 8 s.

Trigger Signal Frequency Counter Resolution

6 digits

Trigger Level Range (Any Channel)

± 4.92 divisions from center of screen.

Trigger Level Range (External/auxiliary input)

±6.25 V, 1x attenuation; ± 12.5 V, 10x attenuation.

Trigger Sensitivity (Internal DC Coupled)

Analog Inputs

0.4 division from DC to 50 MHz; 0.6 divisions >50 MHz to 100 MHz; 0.8 divisions >100 MHz to 200 MHz

External (Auxiliary Input)

200 mV from DC to 100 MHz, 1x attenuation

Waveform Measurements

Cursors

Waveform and Screen

Automatic Measurements

29, of which up to four can be displayed on screen at any one time.

Waveform Math

Arithmetic — Add, subtract, and multiply waveforms.

Display Characteristics

Display Type

7 in (180 mm) liquid crystal TFT color display.

Display Resolution

480 horizontal x 234 vertical pixels (WQVGA).

Waveform Styles

Vectors, Dots (In Video Trigger mode), Variable Persistence, Infinite Persistence.

Graticules

Full, Grid, Cross Hair, Frame.

Format

YT and XY.

Waveform Capture Rate

Up to 5,000 wfms/sec.

Input/Output Ports

USB 2.0 High-Speed Host Port

Supports USB data storage devices and keyboards.

USB 2.0 High-Speed Device Port

Rear-panel port supports communication/control of oscilloscope by PC and all PictBridge compatible printers.

> **Important:** Maximum input voltage (analog channels): 300 VRMS with peaks ≤ 450 V.

> **Important:** Optional LAN/Ethernet (10/100Base-T) and Video Out connectivity is not built in: the LAN port and the Video Out (DB-15) port both require the DPO2CONN adapter, ordered separately.

> **Important:** GPIB is not built in: adapting the rear-panel USB 2.0 device port to GPIB requires the TEK-USB-488 adapter, ordered separately.

> **Important:** Direct attachment of TekVPI current probes requires the TekVPI External Power Supply (Tektronix part number 119-7465-xx), one per oscilloscope.

> **Important:** Please specify power plug and manual version when ordering.

> **Important:** Probes and accessories are not covered by the oscilloscope warranty and Service Offerings; refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.

> Recommended pairing: add TekVPI active, differential, or current probes such as the TAP1500, TDP0500, or TCP0030 for automatic scaling and units through the TekVPI probe interface.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 3520.0 USD - 3800.0 USD
- **Vendor:** Tektronix
- **Type:** Ms Oscilloscope
- **Tags:** Inc., Manufacturers, Mixed Signal, Model 2014, Ms Oscilloscope, MSO2014, Oscilloscopes, Pre-Owned, product_manual_group_1, Product_used, Tektronix

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 3520.00 USD | In stock |
| NIST Traceable | 3730.00 USD | In stock |
| NIST Traceable with Full Data | 3765.00 USD | In stock |
| ISO IEC 17025 Accredited | 3800.00 USD | In stock |

## Images

- Tektronix MSO2014 100 MHz Mixed Signal Oscilloscope (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/mso2014-tektronix-mixed-signal-oscilloscope-used)
> Updated: 2026-06-02