# LeCroy LP142 100 MHz Digital Oscilloscope (Pre-Owned)

# LeCroy LP142 100 MHz Digital Oscilloscope (Pre-Owned)

## Key Features At A Glance

-   100 MHz analog bandwidth (DC–100 MHz) with a 500 MS/s maximum single-shot sampling rate on both channels
-   25 GS/s equivalent-time sampling for up to 40 ps time resolution on repetitive signals
-   100 kpoints long acquisition memory per channel (5 kpoints in short mode)
-   Vertical accuracy within 2% and horizontal accuracy of 50 ppm (0.005%)
-   13 automatic measurements, dual cursors, and a hardware five-digit frequency counter (1 Hz–100 MHz)
-   5.7" (145 mm) backlit LCD with X-Y display and an on-screen Help function
-   RS-232C interface and Centronics data output for waveform and data transfer
-   Built-in line thermal printer plus ATA card and 3.5" floppy storage with TIFF/BMP output

The LeCroy LP142 is a compact digital oscilloscope from the LiteRunner line. At approximately 6.6 lbs (3 kg) and measuring 8.4" x 6.7" x 6.5" (214 x 170 x 166 mm), it is built to be carried easily and to fit onto crowded workbenches, combining a two-channel acquisition system, an integrated 5.7" backlit LCD, and built-in data-output hardware in a single portable package.

An oscilloscope captures electrical signals as waveforms—voltage plotted against time—letting an engineer see a signal's amplitude, frequency, timing, and shape. The LP142 supports this work with cursors and measurement parameters and is suited to troubleshooting signal interruptions, with an on-screen Help function that explains menu functions for both newer and experienced users.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

## Brand Heritage

LeCroy Corporation was acquired by Teledyne Technologies in 2012 and has since operated under the Teledyne LeCroy name.

## Product Core & Specifications

Specification

Value

Acquisition System (Common to CH1, CH2)

Sensitivity

2 mV/div - 10 V/div (1-2-5 steps) (0.8 mV/div zoomed)

Bandwidth

DC - 100 MHz (frequency cutoff is 10 Hz for AC coupling)

Max single-shot sampling rate

500 MS/s

Equivalent sampling mode

25 GS/s

Peak detect

500 MS/s

Resolution

8-bit

Acquisition Memory

Short - 5 kpts/ch; long - 100 kpts/ch

Storage Modes

Normal, equivalent sampling, peak detect, average, roll

Accuracy

Vertical accuracy

Within 2%

Horizontal accuracy

50 ppm (0.005%)

Triggering System

Modes

Auto, Normal, Single

Sources

CH1, CH2, EXT

Types

Edge, Event, TV

Event trigger

Count, Burst, Missing, Extra

Timebase System

Time/div range

5 ns - 50 s/div (1-2-5 steps)

Roll Mode

500 MS - 1000 s/div

Display Functions

Display

5.7" (145 mm) backlit LCD display

X-Y display

X = CH1, Y = CH2

Help function

Available on screen in reverse video

Waveform Storage

Media

ATA card, floppy disk (3.5")

Data type

Setup, waveform

Record format

Binary and ASCII formats are available for waveform data

Comment

Text comments can be appended to waveform files

Auto copy

Waveforms can be automatically copied to a storage device after each trigger

Math and Measurement Functions

Cursors

delta V, delta t, 1/delta t, V at t

Parameters

Tr, Tf, Vrms, Vmean, etc. (total 13 items)

Arithmetic functions

+, -, x

Frequency counter

Five display digits, 1 Hz - 100 MHz frequency range

Other Features

Auto setup

Automatically setup V, H range and trigger for repetitive signal

Interface

RS-232C

Data output

Centronics

Built-in printer

Line thermal printer, roll print available

Floppy, ATA card

Output format TIFF, BMP

Centronics formats

DPU-414, ESC-P09, ESC-P24, PC-PR201, TIFF, BMP

Power Supply

Voltage range

AC 100 - 240 V

Power consumption

90 VA max (with built-in printer operation)

Dimensions and Weight

Dimensions (width, height, length)

8.4" x 6.7" x 6.5" (214 mm x 170 mm x 166 mm)

Weight

Approx. 6.6 lbs (3.0 kg) excluding accessories

> **Important:** AC coupling applies a 10 Hz low-frequency cutoff.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD - 262.5 USD
- **Vendor:** LeCroy
- **Type:** Dig Oscilloscope
- **Tags:** Dig Oscilloscope, Digital, Inc., LeCroy, LP142, Manufacturers, Model 142, Oscilloscopes, Pre-Owned, product_manual_group_1, Product_used, Teledyne LeCroy

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 187.50 USD | In stock |
| NIST Traceable with Full Data | 225.00 USD | In stock |
| ISO IEC 17025 Accredited | 262.50 USD | In stock |